Tokyo, March 26, 2020 – Mitsubishi Electric Corporation (TSE: 6503) announced today that it has developed a new technology for efficient design and material flow of production floor layouts and accurate estimation ® of productivity using Mitsubishi Electric's Maisart *Artificial Intelligence (AI) technology. The combined technology allows for the comparison of highly accurate line improvement plans and reduces the time required to about half the time typically required.
* Itsubishi Electric's AI creates in-line -the-ART technology


   Mitsubishi Electric develops production line improvement technology


An example of using new technology to improve a production line
Key features:
1) The integrated design of layout and material flow improves planning efficiency
This new technology integrates the design of production floor layouts and material flows to quickly identify and resolve potential issues, which is a challenge in a traditional non-integrated design environment. This new technology can also visualize information such as distance intensity (DI) analysis data, which is dynamically generated as design improvements are made. Layouts, material flows, the speed at which materials move between processes, and more can be displayed with easy-to-understand graphics to improve the quality of the plan.
2) AI simulation can accurately estimate the expected productivity growth
The technology automatically generates data for reliable throughput calculations based on data from the actual production process, such as changes in process time and efficiency. Using this data, more than 90% of the production volume can be simulated. In addition, multiple improvement initiatives can be compared based on expected productivity.

More on that
Mitsubishi FX5U series PLC ten advantages Mitsubishi FX5U series PLC ten advantages

1. CPU function As a MELSEC IO-F series PLC actuator, it is equipped with executable structured programs and multiple program actuators, and can be written to ST language and FB. 2. Built-in analog input and output (alarm output by the way) Built-in 12-bit 2-channel analog input ...

Confirmation and clearing of Mitsubishi inverter FR-CS80 alarm history Confirmation and clearing of Mitsubishi inverter FR-CS80 alarm history

When the FR-CS80 inverter detects an abnormality, it will display an error message or alarm in the operation panel according to the abnormal content, or maintain the function action and block the output of the inverter. When maintaining a function operation, please deal with the cause of its operation before resetting the inverter, and then start working. ...

Mitsubishi inverter capacity selection Mitsubishi inverter capacity selection

The capacity (non-functional) of the Mitsubishi inverter for the drive motor can be understood from the change in energy flow determined by the operation method. 1. When accelerating or operating at constant speed The efficiency of the inverter is the output current, that is, how much current the inverter can provide to the motor. Frequency converters ...

Test the output voltage of the inverter – Mitsubishi Test the output voltage of the inverter – Mitsubishi

Because the output voltage of the inverter (Variable-frequency Drive, VFD) is generally 380 volts, there should be no problem in direct measurement, but in practice, most multimeters cannot get a correct reading when testing the output voltage of VFD, and in some cases the multimeter may be burned directly. ...

Mitsubishi takes instructions and outputs instructions Mitsubishi takes instructions and outputs instructions

1) LD (take instruction) A command to connect a normally open contact with the left bus, and every logic line that starts with a normally open contact is used with this instruction; 2) LDI (Reverse Instruction) A normally closed contact is connected to the left bus to the instruction, each ...

Mitsubishi Q Series PLC and GX Works2 connection method Mitsubishi Q Series PLC and GX Works2 connection method

01 USB connection USB connection requires a device USB driver, generally after installing GX Works2 software, it will automatically install the driver, but a single time due to antivirus software or system reasons, may not be installed, then we need to manually drive the device to the accounting machine. The specific device method we ...

Mitsubishi GM AC Servo MR-JE Mitsubishi GM AC Servo MR-JE

One-click adjustments Servo adjustment can be completed with one-button operation without the need for a computer. In addition, the oscillation button control and robust filter can be automatically adjusted. Instantaneous stop tolerance increases It is equipped with an instantaneous stop TOUGH DRIVE function and a large capacitance ft main circuit capacitor. ...

Mitsubishi inverter pre-use debugging method Mitsubishi inverter pre-use debugging method

1. No-load energizing test of Mitsubishi inverter. 1. Ground the ground terminal of the Mitsubishi inverter. 2 Connect the power input terminal of the Mitsubishi inverter to the power supply through the leakage maintenance switch. 3 Check whether the factory display window of the Mitsubishi inverter is normal, if it is not correct.

Mitsubishi inverter encountered problems and solutions Mitsubishi inverter encountered problems and solutions

1. If you want to use the inverter to drive the motor with a capacitor to improve the power factor, but the motor does not move, please explain the reason. The current flowing into the inverter is used to improve the power factor, but the capacitor cannot be started because its charging current causes the inverter overcurrent (OCT), as a countermeasure, ...

Methods for shortening the scanning cycle of PLC programs – Mitsubishi Methods for shortening the scanning cycle of PLC programs – Mitsubishi

1. Try to avoid using "double words" when you can use "words", and try to prevent using real numbers when you can use integers. 2. Give priority to the use of surplus (other than hardware connection) IB, IW, ID, QB, QW, QD, followed by M and S; 3. Try to prevent the transformation of data types, ...

Inverter overload fault factor - Mitsubishi inverter Inverter overload fault factor - Mitsubishi inverter

1) The mechanical load is too heavy The main characteristic of overload is the fever of the motor, and it can be detected by reading the operating current from the display. The main factor is that the load of Mitsubishi inverter is too large, and the acceleration and deceleration time and operation cycle time are too tight; V/F features voltage too ...

Mitsubishi servo motor jog forward and reverse Mitsubishi servo motor jog forward and reverse

Control requirements: press and hold the forward rotation button, the servo motor rotates forward, release the forward rotation button, and the servo motor aborts the work. Press and hold the rotary button, the servo motor rotates, release the rotary button, and the servo motor aborts the work. When turning forward, pressing the turn button has no effect. When turning, pressing the forward turn button is invalid ...

Mitsubishi FR-A700 series inverter problem Mitsubishi FR-A700 series inverter problem

1. Consultation question: FR-A700 series Mitsubishi inverter, the suffix is ending in -CA1, what kind of inverter? Solution: The suffix -CA1 is a special model with take-up control. 2. Consultation question: FR-A ...

Mitsubishi PLC's method of controlling the inverter Mitsubishi PLC's method of controlling the inverter

1. Mitsubishi PLC's analog signal control inverter Hardware: FX1N, FX2N PLC hosts, equipped with 1 simple FX1N-1DA-BD extended analog output board; or analog input-output hybrid module FX0N-3A; or FX2N-2DA with two outputs; or four outputs ...

Ground leakage current of Mitsubishi inverter and countermeasures thereof Ground leakage current of Mitsubishi inverter and countermeasures thereof

There is electrostatic capacitance between the input and output wiring of Mitsubishi inverters and other wires, between the ground and the motor, and there is a leakage current flow. The leakage current value is affected by factors such as electrostatic capacitance and carrier frequency, and the leakage current is high when the carrier frequency of the inverter is set high and the leakage current is operated under low noise conditions.

Performance comparison of Mitsubishi servo motors Performance comparison of Mitsubishi servo motors

First, the control accuracy is different The step angle of the two-phase hybrid Mitsubishi servo motor is generally 1.8 ° and 0.9 °, and the step angle of the five-phase hybrid Mitsubishi servo motor is generally 0.72 ° and 0.36 °. Mitsubishi servo motors, which are also some functions, have a smaller step angle after segmentation. ...

The relationship between torque and performance of Mitsubishi servo motors The relationship between torque and performance of Mitsubishi servo motors

1. Additional torque The torque that occurs on the motor shaft under additional voltage, extra load is called the extra torque of the motor. 2. Starting torque The torque generated by the motor at the moment when a voltage is applied to the motor in a stopped condition is called the starting torque. The starting torque characterizes the electrical...

Pay attention to the wiring of the Mitsubishi PLCI/O terminal Pay attention to the wiring of the Mitsubishi PLCI/O terminal

1. Enter the wiring (1) The input wiring should generally not exceed 30 meters. However, if the environmental disturbance is small and the voltage drop is not large, the input wiring can be appropriately longer. (2) The input/output lines cannot be separated by the same cable, and the input/output lines should be separated. (3) As far as possible, choose normally open ...

The basic logic instructions of the Mitsubishi FX series plc The basic logic instructions of the Mitsubishi FX series plc

Fetch Command and Output Command (LD/LDI/LDP/LDF/OUT) (1) LD (take instruction) - the instruction that the normally open contact is connected with the left bus, and each - logic line that starts with the normally open contact is used with this instruction; (2) LDI ...

Advantages of Mitsubishi Electric fresh air system Advantages of Mitsubishi Electric fresh air system

Mitsubishi Electric's fresh air system realizes indoor ventilation, but of course, we can't just replace the outdoor air into the room, a good fresh air should filter the harmful substances in the air, so that the air entering the room is not only fresh, but also clean and harmless. ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top