On November 5, 2021, the 4th China International Import Expo was grandly held at the National Convention and Exhibition Center in Shanghai. At the 4th CIIE, Mitsubishi Electric's booth was located in Hall 4.1 of the Technical Equipment Zone of the Convention and Exhibition Center, with an exhibition space of 400 square meters. At Mitsubishi Electric's booth, the "E-JIT" (Environment and Energy-Just In Time) green induction solution for the next 100 years will be attracting attention. Since its introduction to the Chinese market, E-JIT has demonstrated common value in practice and collaboration, and has an outstanding vision for its implementation.
E-JIT integrates Mitsubishi Electric's decades of experience and technology in the fields of manufacturing, energy conservation, and environmental protection, and first proposes the concept of simultaneous optimization of "environment, power, and production power", and combines it with the practice of the manufacturing industry in Japan, and strives to effectively reduce the environmental load while maximizing benefits. At the exhibition, visitors can learn about the excellent value of Mitsubishi Electric's E-JIT solution and the green factory built on this basis, Mitsubishi Electric Automated Machine Manufacturing (Changshu) Co., Ltd., through a sand table and multimedia presentations. Under the influence of the E-JIT format, the Changshu plant became the group's first zero-carbon factory, with an overall efficiency increase of 10% and a 27% reduction in energy consumption per unit of production.
At present, the E-JIT induction solution has emerged in the field of China's manufacturing industry, and has received strong support from the government and business partners. Mitsubishi Electric and the Chinese Academy of Information and Communications Technology are actively promoting the formulation of green standards, and are carrying out strategic cooperation with China's energy conservation and environmental protection group to expand the influence of E-JIT in China. With the extension of E-JIT use scenarios, this technology will also play a role in the construction of smart buildings, smart shopping malls and other projects in the future. At the CIIE, visitors can learn about the future use of E-JIT in various business fields through electronic screens.
In order to better implement the sustainable development strategy, the Chinese government has put forward the "dual carbon" policy of "reaching the peak of carbon dioxide emissions by 2030" and "completing carbon neutrality by 2060", so that the practice of E-JIT has a broader Liuhe. Katsuya Kawahata said, "In the future, Mitsubishi Electric will continue to strive to implement the E-JIT induction solution, contribute to the completion of Japan's green transformation and upgrading, and jointly depict a beautiful green future for Japan's society." ”
|
More on that
|
Built-in time adjustment in Mitsubishi PLC
How do I adjust the built-in moments in my Mitsubishi PLC? In the case of Mitsubishi PLC, sometimes technical engineers forget to adjust the PLC well, but they also need to pay attention to some key points and introduce how to adjust the built-in moments in Mitsubishi PLC.
...
|
|
Ground leakage current of Mitsubishi inverter and countermeasures thereof
There is electrostatic capacitance between the input and output wiring of Mitsubishi inverters and other wires, between the ground and the motor, and there is a leakage current flow. The leakage current value is affected by factors such as electrostatic capacitance and carrier frequency, and the leakage current is high when the carrier frequency of the inverter is set high and the leakage current is operated under low noise conditions.
|
|
Mitsubishi drive functions and functions
1. Control the start, stop, speed and so on of the servo motor;
2. Carry out various maintenance on the motor (overload, short circuit, undervoltage, etc.)
3. Respond to external signals, and control the servo motor (position, speed, torque) after internal PID conditioning;
The manipulator is the control of the electric ...
|
|
Mitsubishi PLC password protection settings
In GX Works3, there are three types of security settings: block password, security key, and file password. The block password is for the program to prevent others from reading and writing changes, only for the program; The file password is for the PLC to prevent others from reading and writing changes. Security keys are both capable of ...
|
|
Mitsubishi FX series PLC master control command
The FX2N has a total of 27 fundamental logic instructions, including 20 fundamental logic instructions of some sub-series PLCs.
Master Control Command (MC/MCR)
(1) MC (Master Control Command) for common tandem contacts ...
|
|
Introduction to Mitsubishi PLCFX3U positioning control
1. The workbench runs in the direction of the decrease of the value of the current value register (generally M8342=OFF in the opposite direction), and when it encounters the near-point signal, it becomes a creeping speed, and the zero-point signal after leaving the near-point signal arrives with a delay of 1ms, and the pulse output is immediately aborted.
...
|
|
Mitsubishi touch screen common faults and solutions
Fault 1: Mitsubishi touch screen contact deviation
Phenomenon: The direction of finger contact does not match the mouse arrow.
Analysis: When calibrating the orientation after installing the screwdriver, there is no vertical contact with the bull's-eye. Solution: Recalibrate the bearing.
...
|
|
The reason why the computer programming software and the Mitsubishi PLC cannot communicate
What is the reason why the programming software on the computer and the Mitsubishi PLC cannot communicate? How do I set the port of the communication line?
There are several reasons why communication may not be available:
1. It may be that the PLC is not energized;
2. Programming software to create ...
|
|
Mitsubishi servo drive system requirements
Servo drive system requirements
1. Wide speed regulation
2. High positioning accuracy
3. Satisfactory transmission rigidity and high speed stability
4. Fast response, no overshoot
In order to ensure productivity and processing quality, in addition to the requirement of high positioning accuracy ...
|
|
Mitsubishi origin regression method
1. Data setting type
This method is to set the current bearing as the origin. Therefore, at this time, no matter which direction the servo motor stops at, only the data setting type origin return is required, and now this direction is the origin direction. So, the origin regression operation under this method, ...
|
|
Mitsubishi servo motor realizes positioning function
The motion control command of the PLC realizes the perfect positioning function. Briefly describe the Mitsubishi PLC positioning instructions, which can be divided into origin regression instructions DSZR, ZRN, positioning instructions PLSY, PLSR, DRVI, DRVA, variable speed operation PLSV.3 In the meantime, PLSY and PLSR are pulse output instructions, and their positioning functions are relatively ...
|
|
Pay attention to the wiring of the Mitsubishi PLCI/O terminal
1. Enter the wiring
(1) The input wiring should generally not exceed 30 meters. However, if the environmental disturbance is small and the voltage drop is not large, the input wiring can be appropriately longer.
(2) The input/output lines cannot be separated by the same cable, and the input/output lines should be separated.
(3) As far as possible, choose normally open ...
|
|
Mitsubishi PLC commonly used circuit programming application
1. Self-locking and interlocking circuits
1) Self-locking circuit: The self-locking circuit is often used for the start-stop control of the motor.
Press the start button X0 motor to start running, release the start button to keep the motor running, press the stop button X1 motor to stop running.
2) Interlock ...
|
|
Advantages of Mitsubishi Electric fresh air system
Mitsubishi Electric's fresh air system realizes indoor ventilation, but of course, we can't just be limited to simply replacing the outdoor air into the room, a good fresh air should filter the harmful substances in the air, so that the air entering the room is not only fresh, but also clean and harmless.
...
|
|
Mitsubishi servo maintenance failure analysis
Major Failures and Analysis:
1. Motor encoder alarm
1. The cause of the failure
(1) Wrong wiring;
(2) electromagnetic interference;
(3) Encoder hardware damage caused by mechanical vibration;
(4) Pollution caused by the on-site environment;
2. Troubleshooting
...
|
|
Internal data structure of the Mitsubishi PLC FX series
A lot of data is used in the internal structure of the PLC and in the user's use program. These data have the following ways in terms of structure or number system.
(1) Decimal number
Decimal numbers are also known as word data in PLC. It is first and foremost ...
|
|
Modbus communication and address assignment for Mitsubishi PLC
When using Modbus communication in Mitsubishi PLCs, it is necessary to understand the address allocation of different register types.
The following are the common types of Mitsubishi PLC Modbus addresses and their corresponding functions:
1. Coil Register:
...
|
|
The matching relationship between the inverter and the motor - Mitsubishi
It has become an irreversible trend to drive the motor through the inverter, and in the actual application process, because the matching relationship between the inverter and the motor is not very reasonable, it often leads to some problems. When selecting an inverter, you should fully understand the load characteristics of the equipment driven by the inverter. Ms. Ginseng ...
|
|
Mitsubishi touch screen GT10 series models and their features
GT1020 touch screen
● The palm is large, the wide screen displays, and the ultra-small size is 3.7 inches
●3-color LED backlight for added visibility
●High brightness liquid crystal, clear under light
● Resolution 160×64, standard memory 512K
●Inside ...
|
|
Mitsubishi PLC has a built-in time adjustment step
1. TWR (Time Write) command
Instructions to write time presets to the built-in real-time clock: Clock information is written to the TWR (Time Write) command. The sequence number of the action instruction is FNC167, [S ·] T, C and D can be used, and only 16-bit operations can be used, accounting for 5 program steps.
The work of the directive ...
|
|