Inverter super password summary

Create Date: 2024-8-30 12:03:23|Source: Hope Sunland

1. Delta's super password-B series: 57522; - H-series: 33582; S1 series inverter universal password: 575222.

Second, Huifeng inverter (that is, the current Ou Rui inverter), the common super password of its products is: 18881500-G 1500-P 1000-G 200-G

3. Shuopu inverter, the operation of Shuopu inverter is more complicated, you need to enter the advanced menu P301 input 321A000 input 11, refresh the program; P301 input 321A000 input 9, enter menu E001, enter machine G; PE002 rated voltage, E003 rated current, E004 voltage correction, E005 immobility, E006 current correction

                            Inverter super password summary

Fourth, INVT universal password 50112 model CHV, CHE, CHF in the parameter P7-00 no matter what the password is set to, its universal password is: 501126

5. Mitsubishi 740 does not need a super password, and can be restored to a password-free state by directly unplugging the panel and then plugging it in.

6. The password of Emerson TD3000 is 8888 and the password of Emerson TD3300 is 20028.

7. Universal password of Xilin inverter: 6860.

8. ABB ACS600 inverter full parameter password NAMC main control board parameter settings: 1. Enter the password: 23032 and 102.01 parameter settings in the 16.03 parameter to set all the parameters of the main control board.

9. The inverter of Delta's A series of brands locks the keypad with modified parameters, resulting in most of the parameters being unable to be modified, and the manual does not clearly explain how to unlock the keypad, press MODE and RESET together to display P256 (P256 does not explain what it means in the manual), press ENTER to modify this parameter, change 00 to 01, and press ENTER to exit to modify all parameters.

More on that
Inverter device inspection and maintenance work steps Inverter device inspection and maintenance work steps

1. Preparation process: Abort the device and admit that the motor is completely aborted. Press the stop button on the operator panel to stop the operation. Disconnect the external mains power supply (low-voltage cabinet drawer). Adequate security treatment should be carried out to ensure that it is indeed disconnected and that it does not ...

Inverter control motor speed method - Senlan Inverter control motor speed method - Senlan

1. Why can the rotation speed of the motor be changed freely? The unit of motor rotation speed: r/min the number of rotations per minute, can also be expressed as rpm. Example: 2-pole motor 50Hz3000 [r/min] 4-pole motor 50Hz1500[r/min] Conclusion: The rotation of the motor ...

Advantages of Senlan vector control system Advantages of Senlan vector control system

Dynamic "fast response" DC motors are rectified constrained and excessively high di/dt is not allowed. The asynchronous motor is only constrained by the capacity of the inverter, and the multiple of the forced current can be very high, so the speed echoes quickly, generally reaching the millisecond level, which has surpassed the DC motor in terms of speed. At low frequencies ...

The reason for VFD trip protection - Senlan The reason for VFD trip protection - Senlan

In general, there is a problem with the maintenance trip of the VFD. If you look at the faulty code, you can see what kind of fault is causing it. 1. The selection talent of VFD may be too small; Generally, when selecting VFD, it should be about 20% larger than the rated power of the motor, so that when the motor reaches full load...

Servo motor regular diagnosis and repair method - Senlan Servo motor regular diagnosis and repair method - Senlan

1. Common faults of motor heating up too high or smoke motor Causes: 1. Excessive load; 2. Two-phase operation; 3. Blocked air duct; 4. The working temperature is too high; 5. Interphase or inter-turn short circuit fault of motor stator winding; 6. Motor stator winding grounding device; 7. The power supply voltage is too high or too low; Overhaul...

Hope the advantages of Sunland inverter soft start Hope the advantages of Sunland inverter soft start

It is hoped that Sunland inverter and soft start is a first-class, reliable and reliable motor control system, which can meet the needs of various applications. The advantages of Hope Sunland inverter and soft start are: 1. **Sex: I hope that Sunland inverter and ...

I hope that Senlan will make a wonderful appearance at the 22nd (Shanghai) Industry Fair I hope that Senlan will make a wonderful appearance at the 22nd (Shanghai) Industry Fair

From September 15th to 19th, the 22nd China International Industry Fair was held at the National Convention and Exhibition Center (Shanghai). As the first national industrial exhibition held under the normalization of epidemic prevention and control this year, the theme of this expo is "Intelligence, Interconnection: Enabling the New Development of Industries".

Precautions for inverter wiring - hope Senlan Precautions for inverter wiring - hope Senlan

1. The inverter itself has strong electromagnetic disturbance, which will disturb the operation of some equipment, so we can add a cable sleeve to the output cable of the inverter. 2. The control line in the inverter or control cabinet is spaced at least 100mm, and the power cable is at least 100mm. 3. In the purchase of inverter ...

Sunland - inverter operation process and factory value restoration Sunland - inverter operation process and factory value restoration

The general operation process is as follows: Enter the program through the operation panel and set the parameters, and set the relevant parameter groups such as the start-stop method, operation and control form according to the requirements of the industrial control. After confirming that the wiring is correct, the no-load power on test run and ...

What are the peripheral equipment for inverter selection - Senlan inverter What are the peripheral equipment for inverter selection - Senlan inverter

After the inverter selection is completed, it is necessary to consider whether other peripheral equipment needs to be equipped according to the actual situation of the site. The peripheral equipment for frequency converter selection mainly includes circuit breakers, reactors, contactors, braking resistors, etc. 1. Circuit breaker ...

Inverter water inlet maintenance method - Sunland inverter Inverter water inlet maintenance method - Sunland inverter

The first step is not to turn on electricity! First open the inverter panel, wipe the inverter dry, and then use a hair dryer to dry the display, PC board, push board, power components, fans, etc., with 95% alcohol, scrub the components with 95% alcohol, and dry the hair dryer with cold air. Step 2: After an hour, use alcohol ...

Causes and treatment methods of inverter inverter module damage - Senlan Causes and treatment methods of inverter inverter module damage - Senlan

Most of the damage of the inverter module is due to the damage of the driving electric, which causes the two switching devices on one bridge arm to be turned on at the same time. Inverter inverter power module damage is a common problem in other inverter equipment such as vector inverter or energy-saving inverter.

Hope for an application example of Sunland inverter Hope for an application example of Sunland inverter

Industrial process control: It is expected that Sunland inverters are widely used in industrial process production control, such as conveyors, tugboats, air compressors, pumps, and fans and other equipment in various control systems. Mechanical control: It is expected that Sunland inverters are widely used in mechanical control, such as ...

Senlan inverter motor failure analysis Senlan inverter motor failure analysis

1. The motor slows down too slowly 1) If the deceleration time is set too long, reduce the deceleration time 2) Install a braking resistor 3) Add DC braking 2. The motor is overheated 1) The load is too large, and the practical moment has exceeded the ...

Senlan wiring knowledge Senlan wiring knowledge

1. Wiring of fire emergency lighting Generally, the flame retardant wire is used to wear the metal pipe and the thickness of the protective layer is ≥ 30mm, in the decoration project, when the emergency lighting circuit can only be applied to the ceiling, the heat-resistant or fire-resistant wire should be selected and the fire-resistant and heat-resistant matching should be considered.

Calculation method of braking resistance and power of inverter - Sunland inverter Calculation method of braking resistance and power of inverter - Sunland inverter

(1) Brake usage rate ED% Brake usage rate ED%, that is, the brake usage rate in the clarification book ED%. The brake utilization rate ED% is said to be the deceleration time T1 divided by the deceleration cycle T2, and the brake utilization rate is mainly to allow the braking unit and the brake resistance to have sufficient time to dissipate ...

Sunland SB200 37KW inverter does not show analysis Sunland SB200 37KW inverter does not show analysis

After inspection, the circuit board of the machine is composed of a fan switching power supply board, a control board with a switching power supply and a driving board, etc., the fan power supply and the control board working power supply are independent of each other, the fan power supply output is normal, and the control board working power supply has no output due to failure. ...

The reason why the frequency of the inverter cannot be adjusted - Senlan inverter The reason why the frequency of the inverter cannot be adjusted - Senlan inverter

If there is no damage to the hardware, the maximum torque output of the inverter is generally less than the load to increase the torque. The acceleration time is too short ...

How far apart is the motor from the inverter - Senlan inverter How far apart is the motor from the inverter - Senlan inverter

The supplier of the supporting equipment of the inverter reminds you that the voltage waveform output by the inverter is similar to a sine wave, but not a real sine wave. Its waveform contains a large number of harmonic components, especially the higher harmonics will increase the output current of the inverter, causing the motor winding to heat up, and produce oscillation.

Inverter overcurrent treatment method - Senlan inverter Inverter overcurrent treatment method - Senlan inverter

Overcurrent or overload of the inverter is a common problem of the inverter, and overcurrent refers to the value of the current flowing through the inverter beyond its additional range. 1. If the power supply of the inverter is out of phase, the circuit at the output end is disconnected or the motor winding ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top