From September 15th to 19th, the 22nd China International Industry Fair was held at the National Convention and Exhibition Center (Shanghai). As the first national industrial exhibition held under the normalization of epidemic prevention and control this year, the theme of this expo is "Intelligence, Interconnection - Enabling the New Development of Industries", attracting 2,238 exhibitors from 22 countries and regions around the world, and the professional visitors of this expo increased by 4.3% compared with the previous one.
As an advanced representative of the "knowledge" manufacturing industry in Sichuan Province, I hope that 20 enterprises from Senlan and Sichuan can make a wonderful appearance in the energy-saving and industrial supporting exhibition - Hall 2.1H.
In the mode of product + industry system solutions, the company has successively launched Hope100, Hope510, Hope800 series inverter products, as well as VFPS series shore power supply system, long-distance belt conveyor drive system, high-voltage four-quadrant water-cooled frequency conversion system, showing the company's leading position in the field of speed-regulating electric drive system.
In addition, with the normalization of epidemic prevention and control, the FTI-MED+ series of epidemic prevention products and green intelligent environmental management system solutions created by Continental Hope Group are consistent with the "Science and Technology Enabling Epidemic Prevention and Control" section of the Expo, fully reflecting the new achievements of assisting epidemic prevention and control with industrial science and technology.
The successful holding of the World Expo will play an important role in enhancing the confidence of the global industrial economy, demonstrating China's determination to reform and opening up, and injecting confidence and impetus into the global economic recovery.
|
More on that
|
Wiring specification of inverter control cabinet - Senland
The signal line and the power line must be routed separately: when using the analog signal to remotely control the inverter, the signal line of the control inverter and the strong current circuit (main circuit and sequential control circuit) can be separated from the inverter and other equipment to the analog interference, and the interval should be more than 30cm. Signal ...
|
|
How to choose an inverter - Hope Sunland
The selection of the inverter should be considered according to the type of controlled object, speed regulation scale, static speed accuracy, starting torque, etc., so that it can be easy to use and economical together with meeting the process and production requirements. According to the different forms of devices, it can be divided into four types, which can be divided into four types according to the controlled motor power and field device ...
|
|
Senlan frequency conversion cabinet wiring steps
The wiring of the inverter cabinet refers to the correct connection between the inverter and the motor, power supply and other equipment. The wiring requirements of the cabinet are carried out in accordance with the electrical principles and equipment specifications to ensure the normal operation and safety of the system.
The following is the cabinet ...
|
|
Suppression method of electromagnetic interference of inverter - Sunland inverter
The operating principle of the inverter determines that it will have a certain disturbance, which may bring EMC (electromagnetic compatibility) problems to the equipment or system, and the inverter, as an electronic device, will also be affected by external electromagnetic disturbance.
Below...
|
|
The cause of leakage of the inverter-controlled motor - Senlan
In some fields, the use of inverter to control the motor will present the problem of leakage, and the leakage voltage ranges from tens of volts to 200 volts.
According to the inverter control motor ...
|
|
Senlan inverter selection points
1. Select the inverter according to the load characteristics, such as the load is constant torque load, you can choose Siemens MM440 inverter, ABB ACS800 series inverter, etc.; If the load is a fan or pump load, you can choose Siemens MM430 inverter, ABB ACS510 series inverter, etc.
2、 ...
|
|
The servo motor is connected to the wrong wire and causes a problem - Senlan
If the three power cables of the servo motor (SM) are not connected correctly, there may be no alarm in the static state. But as soon as the motor is operated manually or actively, the motor jumps off or starts to flutter, such as jumping when the speed is added too high, the system will issue generalized faults, etc.
|
|
Senlan inverter external detection and judgment
1. The power-on trip or the main power terminal part of the inverter shows a spark.
Detection method and discrimination: disconnect the power line, check whether the input terminal of the inverter is short-circuited, and check whether the DC side terminals P and N of the central circuit of the inverter are short-circuited. It may be due to a damaged rectifier or a central ...
|
|
Whether the front end of the inverter can be installed with a motor protector - Senlan
Frequency conversion speed regulation motor is generally selected 4-level motor, the fundamental frequency operation point is planned at 50Hz, the frequency 0-50Hz (speed 0-1480r/min) scale of the motor for constant torque work, the frequency of 50-100Hz (speed 1480-2800r/min) scale of the motor for constant power work, the whole speed regulation scale of (0 ...
|
|
Hope Sunland grid-connected PV inverter
Grid-connected photovoltaic inverter is one of the core components of solar photovoltaic power generation system, the main types are: central inverter, modular inverter, micro inverter, DC ...
|
|
Motor encoder and rotor pole phase zero alignment repair - Sunland
1. Phase alignment method of incremental encoder
The alignment between the phase of the UVW electronic transmutation signal and the phase of the rotor pole, or the phase of the TV spot, of the incremental encoder with the signal exchange is as follows:
1) Use a DC power supply to pass the UV winding of the motor to less than the amount of ...
|
|
Sunland low-voltage inverter division series
1.HG1000 high-performance light-load intelligent inverter, the most cost-effective, the new series is widely used in medicine, food, packaging, cable, printing and dyeing, washing, centrifuge, dehydrator, sewage treatment, HVAC, constant pressure water supply, constant temperature control, flow control and other industries, such as fans and pumps, ...
|
|
Inverter with no-load operation and debugging - Hope Sunland
The following four steps are very important for the commissioning of the inverter with the machine (i.e., connected to the motor) and no-load (i.e., the motor without load).
(1) Set the power of the motor, the number of pole pairs, and check the operating current of the inverter.
( ...
|
|
Inverter with no-load operation debugging steps - Sunland inverter
The following four steps are very important for the commissioning of the inverter with the machine (i.e., connected to the motor) and no-load (i.e., the motor without load).
(1) Set the power of the motor, the number of pole pairs, and determine the working current of the inverter.
( ...
|
|
Switching power supply failure maintenance - Senlan
In the process of repairing the switching power supply, the step-down method can be selected. The method is: by connecting the power plug of the display to a communication voltage regulator, and then adjusting the output voltage of the voltage regulator to about 100V, and then repairing it with electricity, and gradually improving the power supply voltage for repair. ...
|
|
Sunland inverter electromagnetic interference suppression method
When the peripheral equipment and the inverter share the same power supply, the disturbance generated by the inverter is transmitted against the power line, which will cause other equipment in the same system to malfunction. The following methods can be adopted:
(1) The input device of the inverter is equipped with an EMI filter or a ferrite common-mode filter (magnetic ring) ...
|
|
Senlan wiring knowledge
1. Wiring of fire emergency lighting
Generally, the flame retardant wire is used to wear the metal pipe and the thickness of the protective layer is ≥ 30mm, in the decoration project, when the emergency lighting circuit can only be applied to the ceiling, the heat-resistant or fire-resistant wire should be selected and the fire-resistant and heat-resistant matching should be considered.
|
|
Practical installation precautions for frequency converters
When the line power supply exceeds the driver's kV-A rating by 10 times, add a line reactor.
A 3% impedance line reactor should be used to reduce power line transient voltages caused by capacitor switching, line notching, DC bus overvoltage tripping, and inverter overcurrent and overvoltage conditions. Line...
|
|
Inverter heat dissipation treatment in use - Sunland inverter
If you want to make the inverter last a long time, you must seriously consider the problem of heat dissipation. Because the failure rate of the inverter increases exponentially with the increase of temperature, the service life decreases exponentially with the increase of temperature. A 10 degree increase in ambient temperature halves the service life of the inverter. Thus...
|
|
Fault signal processing method of frequency converter
(1) Check whether the motor is hot.
If the temperature rise of the motor is not high, you should first check whether the size of the load, the acceleration and deceleration time, and the running cycle time are reasonable, and correct the V/F characteristics, and check whether the electronic thermal protection function of the inverter is preset reasonably, such as the inverter.
|
|