Senlan wiring knowledge

Create Date: 2024-8-30 12:03:23|Source: Hope Sunland

1. Wiring of fire emergency lighting

Generally, the flame retardant wire is used to wear the metal pipe and the protective layer thickness is ≥ 30mm, in the decoration project, when the emergency lighting line can only be applied in the ceiling, the heat-resistant or fire-resistant wire should be selected and the fire-resistant and heat-resistant wiring method should be considered.

Second, the wiring of the fire elevator

The fire elevator is generally distributed by the substation on the ground floor of the high-rise building to the elevator machine room on the top floor, because the line is longer and the route is more complex, the fire elevator distribution line should be selected fire-resistant cable; When there are special requirements for reliability, one of the two distribution lines can choose mineral insulated cables.

3. Wiring of fire shutter doors

The power supply of the fire shutter door is generally drawn from the floor distribution box with dual power switching, and the power supply is supplied to the control box by radial or ring power supply through the special distribution box of the fire shutter door. When the horizontal distribution line of the fire shutter door is long, it is advisable to choose fire-resistant cables and use fire-resistant cable trays in the ceiling.

                              Senlan wiring knowledge

Fourth, the wiring of smoke prevention and exhaust equipment

For the distribution line of smoke prevention and exhaust equipment, fire-resistant cross-linked low-voltage cable or mineral insulated cable is selected when it is laid open, and general fire-resistant cable can be used when it is concealed. The linkage and control lines of smoke prevention and exhaust equipment are made of fire-resistant cables. The length of the line of smoke prevention and exhaust equipment should be shortened as much as possible when laying to avoid crossing different fire zones.

5. Wiring of fire hydrant pumps, sprinkler pumps, etc

The distribution line of the pump motor often uses flame-retardant wire to pass through the metal pipe and bury it in the non-combustible structure, or the fire-resistant cable is selected and equipped with a fire-resistant cable tray, or the mineral insulated cable is selected. The power supply of the pump room is generally directly supplied by the substation of the high-rise building; When the substation is adjacent to the pump room and belongs to the same fireproof partition, the fire-resistant cable or fire-resistant bus is selected to be laid along the fireproof cable tray; When the substation is far away from the pump room and passes through different fire partitions, mineral insulated cables can be used.

6. Causes of overheating of electrical equipment

1) Short circuit: The formation of a metallic touch between the phase wire and the neutral line or between the phase wire is a short circuit. When the temperature rises sharply during a short circuit, the insulating material burns and a fire occurs.

2) Overload: The current value of the electrical line or equipment exceeds the value of its promise, it is overload. Overload can cause insulation burnout.

3) Poor touch: The electrical connection part is commonly welded or bolted, once loosened, the touch resistance of the connection part increases, and the joint is overheated, resulting in disasters.

4) Core heating: The core insulation is damaged due to the increase in heat generation, which will produce high temperatures.

5) Poor heat dissipation: The heat dissipation method of electrical appliances is damaged, which will form overheating.

7. What are the causes of electrical fire blasting?

Electrical circuits, motors, oil-immersed power transformers, switchgear, electric lights, electric heating equipment, etc., have different risks and causes of fire and explosion due to different structures and operating characteristics. However, in general, in addition to equipment defects, improper equipment and other reasons, in operation, the heat of the current and the spark or arc of the current are the direct causes of fire blasting.

8. What are the fundamental methods for electrical fire and explosion protection?

According to the characteristics of the place, the fundamental methods adopted for electrical fire and explosion prevention are:

1) Correct selection of electrical equipment. Explosion-proof electrical equipment should be selected according to the standard for places with blasting risk.

2) Selecting a reasonable equipment location according to the standard and insisting on the necessary safety distance is an important method for fire and explosion prevention.

3) Strengthen maintenance and maintenance, and insist on the normal operation of electrical equipment: including insisting that the voltage, current, temperature rise and other parameters of electrical equipment do not exceed the promised value, insisting on sufficient insulation ability of electrical equipment, and insisting on excellent electrical connection.

4) Ventilation: in blasting risk places. If there is excellent ventilation, it can reduce the thick bottom of the explosive mixture. Technical training is worth your attention!

5) The selection of fire-resistant equipment plays a very important role in on-site fire prevention. For example, in order to improve the fire resistance, the inner surface of the wooden switch box is lined with white iron sheet.

6) Grounding: The grounding (or zeroing) of blasting risk places is higher than that of general places. It must be grounded as specified.

9. What is a zero-sequence current transformer?

The primary loop of the transformer of the zero-sequence current of the exploration power supply line is the phase line (La, Lb, Lc). That is, all phase lines pass through the window at the same time and in the same direction. If used for a single phase, the effect is the same as that of a normal current transformer (C.T).

10. What is a residual current transformer?

The primary circuit of the transformer that explores the remaining current of the power supply line is the phase wire (La, Lb, Lc) and the neutral line N. That is, the phase line and the neutral line pass through the window at the same time and in the same direction. The primary requirements for the remaining current transformers are high accuracy in the mA class and overload resistance of more than 40A.

11. What is the grounding current?

The current flowing into the ground due to insulation defects or unexpected loads. It is commonly known as "leakage current". This current is generated by an arcing short circuit between the phase line and the ground. It is generally accepted that in a non-combustible environment, less than 100 mA does not pose a fire risk.

12. What is normal leakage current?

In the absence of insulation problems, the current flowing into the ground from the live parts of the device. This current is often caused by a non-pure impedance, which is determined by the intrinsic operating characteristics of some devices and promised within a certain range.

13. What is zero-sequence current?

Vector sum of currents communicating the phase wires (La, Lb, Lc) of the power supply line. When no grounding problem occurs, the theoretical value of this vector sum is equal to the value of the neutral N current. When a grounding fault occurs, the zero-sequence current is the vector sum of the current of the phase wire (La, Lb, Lc), the grounding fault current and the normal leakage current; At this time, it is not equal to the neutral N current.

14. What is residual current?

Vector sum of currents of the phase wires (La, Lb, Lc) and neutral lines N of the communication supply line. When there is no single-phase grounding problem, regardless of whether the three-phase load is balanced or not, the theoretical value of this vector sum is zero (in fact, there is still the normal leakage current of the line and equipment); When a grounding fault occurs, the remaining current is the vector sum of the grounding fault current and the normal leakage current.

More on that
Damage and repair of internal electronic components of the inverter - Hope Sunland Damage and repair of internal electronic components of the inverter - Hope Sunland

1. Repair the damage of the inverter rectifier block The damage of the inverter rectifier bridge is also one of the common faults of the inverter, the inverter rectifier block in the early production is mainly diode rectifier, and now some rectifier blocks choose the rectifier mode of thyristor (voltage regulation and frequency modulation inverter). Middle...

The difference between Sunland inverter and soft starter The difference between Sunland inverter and soft starter

What is a frequency converter? The inverter is a converter that converts the communication electricity with fixed voltage and frequency into the communication electricity with variable voltage and frequency, which is called the inverter. It is mainly used in the local demand for speed regulation, and its output not only changes the voltage but also changes the frequency together; The soft engine is really ...

Sunland low-voltage SB70 inverter is used in position control Sunland low-voltage SB70 inverter is used in position control

Sunland's low-voltage SB70 inverter integrates a high-precision rotor magnetic field directional vector control algorithm, with 250% instantaneous torque control capability. It has the original multi-form PLC operation function, which is especially suitable for industrial cleaning equipment and manufacturing equipment. Practical multi-speed function: two sets of parameters, can be rooted ...

Selection and capacity matching of inverter - Senlan Selection and capacity matching of inverter - Senlan

1. Select the inverter according to the load characteristics Second, when selecting the inverter, the actual motor current value should be used as the basis for the selection of the inverter, and the extra power of the motor can only be used as a reference. Secondly, it should be fully considered that the output of the inverter contains higher harmonics, which will form the power factor of the motor.

Analysis of the causes of bearing damage - Hope Sunland Analysis of the causes of bearing damage - Hope Sunland

In the process of using bearings, often due to some external factors cause some wear in the rotation of the bearing, and these bearing wear will be completely damaged in the addition of day by day, which requires our maintenance personnel to replace the bearing, and generally form a bearing.

The reason for adding a frequency converter to the crane control system - Senland The reason for adding a frequency converter to the crane control system - Senland

Prior to the introduction of frequency converters, overhead crane operators operated the cranes using contactor-based controls. For low-cycle cranes, the system is equipped with a single or two-speed motor. For cranes with higher load cycles, they use so-called wound rotor motors. ...

The inverter is regularly replaced with the device - Sunland inverter The inverter is regularly replaced with the device - Sunland inverter

1. Cooling fan As a prerequisite for ensuring the normal operation of the inverter, efficient and fast in-line cooling fans have become an indispensable conversion configuration of the inverter. Because of the wear of the internal bearings of the cooling fan and the reduction of the grease function in the process of application, the cooling of the fan.

Excessive capacity of the inverter causes harm to electrical equipment - Senlan inverter Excessive capacity of the inverter causes harm to electrical equipment - Senlan inverter

(1) The harmonic current generated will directly cause the additional heating of the motor, so that the stator of the motor surpasses the additional temperature rise of the motor itself, so that the additional output capacity of the motor will be greatly reduced. (2) The current output of the inverter ...

Energy-saving operation method of air compressor inverter - Senland Energy-saving operation method of air compressor inverter - Senland

At present, the domestic air compressor market takes the goal of energy saving, environmental protection and cost reduction as the primary demand, and the new products developed are very popular. However, economically speaking, it cannot completely replace the conventional screw air compressor with large area and large capacity in use. Therefore, the use of inverter technology to ...

I/O (Input/Output) Selection – Senland I/O (Input/Output) Selection – Senland

In the 90s of the 20th century, PLC has formed a variety of PLCs: micro, small, medium, large and giant. According to the number of I/O points, it can be divided into five types: micro PLC (32 I/O), small PLC (256 I/O), medium PLC (1024 I/O), large PLC (4.69 I/O), and giant PLC (8195 I/O). ...

Precautions for inverter wiring - hope Senlan Precautions for inverter wiring - hope Senlan

1. The inverter itself has strong electromagnetic disturbance, which will disturb the operation of some equipment, so we can add a cable sleeve to the output cable of the inverter. 2. The control line in the inverter or control cabinet is spaced at least 100mm, and the power cable is at least 100mm. 3. In the purchase of inverter ...

Asynchronous motor with inverter method - Senlan Asynchronous motor with inverter method - Senlan

Before the asynchronous motor is equipped with an inverter, let's take a look at the three major types of mechanical equipment loads: 1. Constant torque load: such as conveyor belt and mixer; When the inverter drags the load of constant torque nature, the torque at low speed should be large enough, and the overload should be large enough. If you need ...

The difference between a voltage signal and a current signal The difference between a voltage signal and a current signal

The general voltage in industry is 0... 5(10)V or current 0(4)... 20mA is used as an analog signal transmission method, and it is also a method often used by program control machines. So what is the difference between the transmission method of voltage and current, and when to choose what method, the following will be briefly introduced.

What should I do if I forget the password? What should I do if I forget the password?

With the passing of time, the inverter has now fully penetrated into the work of major industries. In our daily use, we will inevitably encounter all kinds of problems. For example, I forgot the cipher code of the inverter. See here ...

I hope that Senlan will make a wonderful appearance at the 22nd (Shanghai) Industry Fair I hope that Senlan will make a wonderful appearance at the 22nd (Shanghai) Industry Fair

From September 15th to 19th, the 22nd China International Industry Fair was held at the National Convention and Exhibition Center (Shanghai). As the first national industrial exhibition held under the normalization of epidemic prevention and control this year, the theme of this expo is "Intelligence, Interconnection: Enabling the New Development of Industries".

The difference between vector and general use of frequency converter The difference between vector and general use of frequency converter

1. The control accuracy of the vector type is higher than that of the general type. 2. The vector type has a large output torque at low speed, which can make the motor get a larger starting torque, and is suitable for use in the occasion of heavy load starting, such as: high-power long belt, hoist, etc. If it is used in some of the more common fields ...

Servo motor regular diagnosis and repair method - Senlan Servo motor regular diagnosis and repair method - Senlan

1. Common faults of motor heating up too high or smoke motor Causes: 1. Excessive load; 2. Two-phase operation; 3. Blocked air duct; 4. The working temperature is too high; 5. Interphase or inter-turn short circuit fault of motor stator winding; 6. Motor stator winding grounding device; 7. The power supply voltage is too high or too low; Overhaul...

Sunland Shore Power Innovation - The world's first high-voltage water-cooled four-quadrant shore power system rolled off the production line Sunland Shore Power Innovation - The world's first high-voltage water-cooled four-quadrant shore power system rolled off the production line

In order to thoroughly implement the spirit of General Secretary Xi Jinping's important instructions that the economic power must be a maritime power, a shipping power, economic development, a strong country, and transportation, especially shipping, and the implementation of the outline for the construction of a transportation power, the port ship shore power system has become the standard for green ports.

According to the load characteristics, choose the inverter - Senland According to the load characteristics, choose the inverter - Senland

The types of production machinery are complex, the functional and process requirements are different, and the torque characteristics are also different, therefore, before the application of the inverter, the first thing is to understand the nature of the load carried by the motor, that is, the load characteristics, and then select the inverter and the motor. There are three types of loads: ...

The harm of low temperature to the inverter - Senlan The harm of low temperature to the inverter - Senlan

Most VFDs are suitable for -10°C-50°C, and if the temperature is too low, the VFD will be affected. Precautions for low-temperature operation of VFD: 1. VFD should be operated in an environment above minus 10°C as much as possible, preferably indoors.

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top