In general, there is a problem with the maintenance trip of the VFD. If you look at the faulty code, you can see what kind of fault is causing it.
1. The selection talent of VFD may be too small; Generally, when selecting VFD, it should be about 20% larger than the rated power of the motor, so that when the motor reaches full load, the VFD can still drive.
2. Because of the internal void of the fan, because of the deposition of gas impurities and rust in the fan, the gap between the rotor, the rotor and the cavity will be reduced, so that the load resistance will increase, and the motor and VFD will be overloaded.
3. Because the power supply voltage is high, more than 410V, the internal heat of the inverter will be added, and the inverter will overheat, resulting in maintenance tripping. When the supply voltage drops below 360V, the operating current of the inverter will be added and the overcurrent maintenance will be tripped.
4. There is a lot of dust in the inner plate and radiator of the VFD, which greatly reduces its heat dissipation effect and makes the VFD trip due to overheating maintenance.
5. In case of lightning or large-scale equipment starting, it will cause the power grid voltage to fluctuate, and the VFD voltage loss maintenance trips.
6. The serious problem is that one of the rectifier modules inside the inverter is damaged, resulting in the other two circuits being in an overcurrent state when they are working.
|
More on that
|
Senlan SV1000 servo drive wearing parts replacement
The wearing parts of the driver mainly include electrolytic capacitors for filtering and cooling fans, and their service life is closely related to the environment and maintenance of the operation.
Depending on the operating moment, the user can determine whether a wear part needs to be replaced.
Cooling ...
|
|
EMC rules for inverters - Sunland inverters
When various factory equipment uses frequency conversion speed regulation, harmonic disturbance will occur on the power supply side and motor side of the inverter (VFD), which will form electromagnetic disturbance to the power supply network and other electrical equipment near the VFD. In addition, in order to ensure the long-term reliable operation of the VFD, the wiring of the VFD is very important.
...
|
|
Measures to prevent overvoltage of inverter - Sunland inverter
Depending on the cause of overvoltage, the countermeasures adopted are different. Regarding the overvoltage phenomenon that occurs in the parking process, if there is no special requirement for the parking time or direction, then the extension inverter deceleration time or free parking method can be selected to solve it. The so-called free parking ...
|
|
Introduction to the main series of Sunland inverter products
SB150
SB150 is a delicate and practical inverter launched by Sunland, with exquisite and delicate appearance, exquisite and perfect circuit, simple and practical function, and clear and reasonable menu distinction. At the center of the SB150 is Sunland's high-performance optimized space vector ...
|
|
Precautions for the use of industrial touch screen all-in-one machine
1. The contact screen all-in-one machine adopts the new contact identification technology, and the user only needs to touch it lightly on the contact screen without passing the pressure sensing to complete the operation. Care must be taken not to use too much force or sharps to scratch the surface of the contact screen.
...
|
|
Inverter control method for motor - Senlan
1. U/f stable control
U/f control is to change the voltage of the motor power supply together with changing the frequency of the motor power supply, so that the magnetic flux of the motor is kept constant, and the efficiency and power factor of the motor do not decrease within a wide range of speed regulation. Because it is to control the voltage and frequency ...
|
|
Inverter parameter setting - Sunland inverter
There are many setting parameters of the inverter, each parameter has a certain selection scale, and the inverter can not work normally due to the improper setting of individual parameters in use, so it is necessary to set the relevant parameters correctly.
...
|
|
A contactor is used between the inverter and the motor - Senlan inverter
Whether a contactor is used between the inverter (VFD) and the motor depends on the specific situation. When the contactor is on and off when the motor is running, the operating overvoltage is easy to cause VFD damage. Therefore, whether to use the contactor, it must be based on the actual situation to make the correct ...
|
|
Senlan inverter motor failure analysis
1. The motor slows down too slowly
1) If the deceleration time is set too long, reduce the deceleration time
2) Install a braking resistor
3) Add DC braking
2. The motor is overheated
1) The load is too large, and the practical moment has exceeded the ...
|
|
The inverter is different from the inverter power supply - Senland
In terms of power supply, everyone may know that the inverter and the inverter power supply are auxiliary equipment for charging electrical appliances, but many people do not know what is the inverter power supply and what is the inverter. With the continuous progress of the times, electrical appliances will be constantly updated, and auxiliary equipment is constantly changing.
|
|
Switching power supply failure maintenance - Senlan
In the process of repairing the switching power supply, the step-down method can be selected. The method is: by connecting the power plug of the display to a communication voltage regulator, and then adjusting the output voltage of the voltage regulator to about 100V, and then repairing it with electricity, and gradually improving the power supply voltage for repair. ...
|
|
Inverter with no-load operation and debugging - Hope Sunland
The following four steps are very important for the commissioning of the inverter with the machine (i.e., connected to the motor) and no-load (i.e., the motor without load).
(1) Set the power of the motor, the number of pole pairs, and check the operating current of the inverter.
( ...
|
|
Senlan inverter selection points
1. Select the inverter according to the load characteristics, such as the load is constant torque load, you can choose Siemens MM440 inverter, ABB ACS800 series inverter, etc.; If the load is a fan or pump load, you can choose Siemens MM430 inverter, ABB ACS510 series inverter, etc.
2、 ...
|
|
Introduction to the speed regulation mode of inverter motor - Senlan
1. Mechanical speed regulation form
There are three methods of mechanical speed regulation: electromagnetic clutch, hydraulic coupling, and viscous clutch. Among them, the hydraulic coupling device is widely used, that is, a hydraulic coupling device is connected in series between the motor and the load, and the concave and convex liquid level is used to adjust the hydraulic coupling between the motor and the load.
|
|
Sunland won the "well-known brand of China's domestic inverter" for the fifth time in a row
On April 15, 2011, the "Century Tour of China's Automation Industry (CAIE2011)" was held in Beijing, and Sunland inverter was once again re-elected as "China's well-known brand of domestic inverter". Dr. Chen Bin, President of Continental Hope Group and Chairman of Hope Sunland Technology Co., Ltd., personally ...
|
|
The reason for the increase of the torque of the inverter - Senlan inverter
It is important to set the torque to improve the function. When the power frequency of the motor decreases, the speed of the motor will also decrease, and if the load torque remains unchanged, the output power will also decrease. According to the principle of conservation of energy, if the rotation of the load ...
|
|
Damage to the inverter power module of the inverter - Senland
1. Discrimination
The inverter power module mainly includes IGBT, IPM, etc., check whether the appearance has exploded, and whether there are ablation marks between the terminal and the connected printed board. Use a multimeter to check whether C-E, G-C, G-E have been passed, or use a multimeter to measure whether the resistance of P to U, V, W and N to U, V, W is inadequate.
|
|
Anti-interference measures in the application of Sunland inverter
The main manifestations of the disturbance of the inverter in the application are: higher harmonics, noise and oscillation, load matching, heat generation and other problems. These disturbances are unavoidable, because the input part of the inverter is a rectifier circuit and the output part is an inverter circuit, both of which are made up of nonlinear components that play a switching effect.
|
|
Hope the advantages of Sunland inverter soft start
It is hoped that Sunland inverter and soft start is a first-class, reliable and reliable motor control system, which can meet the needs of various applications. The advantages of Hope Sunland inverter and soft start are:
1. **Sex: I hope that Sunland inverter and ...
|
|
The connection method of the shielded wire adheres to the principle - Senlan inverter
1. The shield wire should be as close as possible to the low potential end, which can be understood in this way, generally we think that the ground potential is "0", and in reality, if there are two grounding terminals, there will be a potential difference between the two grounding terminals at a certain time, and there will be a current between the two wires, which is also a kind of agitation.
|
|