1. Preparation process:
Abort the device and admit that the motor is completely aborted.
Press the stop button on the operator panel to stop the operation.
Disconnect the external mains power supply (low-voltage cabinet drawer). Adequate security treatment should be carried out to ensure that the disconnection is indeed carried out and that no misuse occurs.
Look at the power indicator on the control and inverter (soft starter) panels to ensure that the controls are calmed.
Disconnect the control power air switch (safely).
Wait more than 5 minutes.
Open the door lock of the inverter (soft starter) cabinet and flip open the cabinet door.
Check the power at the input terminal of the main circuit to ensure that the voltage of the main circuit is at a safe level.
When the door of the inverter (soft starter) unit cabinet is opened, the LED light of the inverter (soft starter) of all units is acknowledged to be turned off.
Check that there is no voltage in the external cable terminations used to connect the control cabinet.
Check the input of the control power supply to ensure that the control supply voltage is at a safe level.
Ground the three-phase input power supply at the main circuit input.
Start reviewing and maintaining.
In the case of replacing the unit inverter (soft starter), please follow the instruction manual inverter (soft starter) operation manual.
2. Recovery process:
(1) Remove the grounding wire of the main circuit.
(2) Turn on the control power and close the door. If you don't connect the control power supply, it won't work.
(3) Send power to the external main power supply (low-voltage cabinet drawer). When the external mains power is put on, it must be recognized that the indicator light on the control panel is on.
(4) Carry out safety recognition and make preparations for work.
|
More on that
|
Senlan inverter multi-stage speed parameter setting
The external terminals of the inverter, RH, RM, RL, are speed control terminals. Through the combination of these terminals, three-speed and seven-speed control can be completed. In addition, the other terminals can be redefined, and the fifteen-speed speed can be controlled.
...
|
|
The remote control of the inverter meets the function - Sunland inverter
In general, the long-distance operation of the frequency converter requires the following functions:
1) Long-distance setting, if the parameters only need to be set for the first time, and do not need to be adjusted during operation, then long-distance setting is not required.
2) Long-distance start-stop, long-distance start or stop inverter, and ...
|
|
The device inside the inverter that needs to be replaced regularly - Sunland
1. Cooling fan
As a prerequisite to ensure the normal operation of the inverter, efficient and fast in-line cooling fans have become an indispensable conversion configuration of the inverter. Because of the wear of the internal bearings of the cooling fan and the reduction of the grease function in the process of application, the cooling of the fan.
|
|
The inverter's requirements for the surrounding environment - Senlan
1) Operating temperature: The inverter is a high-power electronic component, which is simply affected by the operating temperature, and the general temperature requirement is 0 - 55. However, in order to ensure the safety and reliability of the operation, it is necessary to consider freeing up space when using, and it is best to control it below 40. The inverter generally requires the device to operate ...
|
|
Get to know the capacitor of the inverter - Sunland inverter
1. The capacitance is generally indicated by "C" plus a number in the circuit (e.g., C25 indicates the capacitance numbered 25).
A capacitor is a component composed of two metal films close to each other and separated by an insulating material in the center. The characteristic of the capacitor is first and foremost the communication through the DC block. The size of the capacitance is ...
|
|
Senlan inverter selection principle
1. Select the inverter according to the load characteristics, such as the load is constant torque load, you can choose Siemens MM440 inverter, ABB ACS800 series inverter, etc.; If the load is a fan or pump load, you can choose Siemens MM430 inverter, ABB ACS510 series inverter, etc.
2、 ...
|
|
Commonly used motor protection method - Hope Sunland
1. Install a reactor at the output of the inverter: This method is the most commonly used, but it should be noted that this method has a certain effect on shorter cables (less than 30 meters), but sometimes the effect is not ideal.
2. In the inverter ...
|
|
The cause of vibration and noise in the inverter - Sunland inverter
Generally speaking, the inverter will inevitably present some problems during operation, such as oscillation and noise, which are common problems in VFD operations. So, what causes oscillation and noise in VFDs? What is the solution to these problems? Here are the causes of VFD oscillation and noise ...
|
|
At the physical level, the stable operation of the inverter is guaranteed-Senlan inverter
For the most popular electrical control equipment inverter (Variable-frequency Drive, VFD), as a precision electronic industrial control equipment, in order to run smoothly for a long time, we, as professional and technical personnel, need to be on the VFD device or before the operation.
|
|
Introduction to the main series of Sunland inverter products
SB150
SB150 is a delicate and practical inverter launched by Sunland, with exquisite and delicate appearance, exquisite and perfect circuit, simple and practical function, and clear and reasonable menu distinction. At the center of the SB150 is Sunland's high-performance optimized space vector ...
|
|
Hope for an application example of Sunland inverter
Industrial process control: It is expected that Sunland inverters are widely used in industrial process production control, such as conveyors, tugboats, air compressors, pumps, and fans and other equipment in various control systems.
Mechanical control: It is expected that Sunland inverters are widely used in mechanical control, such as ...
|
|
Hope Senland's introduction to the charging module
The charging module is a DC charging module developed to meet the high voltage and high current of electric vehicles. The module has many advantages such as high efficiency, high power factor, high power density, and high reliability. The module selects the three-phase AC input method without a centerline. DC output voltages range from 250V to 750V ...
|
|
The output side of the inverter is equipped with a contactor - Sunland inverter
When the power supply and the inverter are replaced, for example, if the inverter has a problem, in order to make an emergency, let the motor be directly changed to be driven by the power frequency power supply; Perhaps the inverter is used for soft starting, and after the motor is accelerated to the power frequency speed, it is changed to be driven by the power frequency power supply.
...
|
|
Common brand inverter modification power method - Senlan inverter
What are the advantages of inverter power correction? Many brands of inverter power boards, driver boards, and motherboards can be universal, as long as the type, volume, and hardware are the same, and the desired power and voltage value can be obtained by correcting the manufacturer's parameters.
...
|
|
Methods to reduce the maintenance cost of inverter - Senlan inverter
Frequency converter is a widely used equipment in modern factories. This is a very expensive new type of equipment, and the maintenance price of the inverter is also very expensive, so in the process of using the inverter, we should pay attention to the use of the inverter.
Thing...
|
|
Effect of inrush current on inverter - Senlan
In the process of repairing the inverter, we can find that because of the back electromotive force in the stator winding, the electromotive force in the synchronous generator state and the self-induced electromotive force in the self-loop rotor, the current impact will inevitably have a negative impact on the motor, the inverter (Variable-frequency ...
|
|
Inverter load type - Sunland inverter
(1). Constant torque load
Different speeds, load resistance and torque base are stable. The output power is directly proportional to the rotational speed. Such as belt conveyors.
(2). Constant power load
Different speeds, stable load power base ...
|
|
Suppression method of electromagnetic interference of inverter - Sunland inverter
The operating principle of the inverter determines that it will have a certain disturbance, which may bring EMC (electromagnetic compatibility) problems to the equipment or system, and the inverter, as an electronic device, will also be affected by external electromagnetic disturbance.
Below...
|
|
About the basic selection of Hope Sunland inverter
It is hoped that Sunland low-voltage inverter can be divided into four series:
1.HG1000 high-performance light-load intelligent inverter, the most cost-effective, the new series is widely used in medicine, food, packaging, cable, printing and dyeing, washing, centrifuge ...
|
|
Senlan brought its products to the Guangxi International Sugar Technology and Equipment Exhibition
Recently, it is expected that Sunland will successfully participate in the 8th Guangxi World Sugar Industry Skills and Equipment Expo with excellent inverter products. According to the expected Sunland company leakage, the exhibition of the World Sugar Industry Skills and Equipment Expo, throughout the exhibition to domestic equipment manufacturers, there is no lack of foreign outstanding enterprises, exhibitors ...
|
|