VFD center power electronics and control mode

Create Date: 2024-8-30 12:03:23|Source: Delta/Delta

1) Power electronic equipmentPower electronic equipment is the equipment that plays the effect of on-off in the circuit and completes various conversions, VFD is the installation of this conversion, so it is carried out with the development of inverter equipment, and the quality of inverter equipment depends on its on-off ability, and accepts the current and additional voltage of on-off; In the on-off process, the size of the loss, such as saturation, voltage drop and switching loss, determines the power and volume of the VFD. Switching losses are related to the switching frequency; The switching frequency is related to noise, and is related to the output voltage and current waveform. That is to say, the power electronic equipment should be deployed in the direction of high voltage, high current, high switching frequency and small on-voltage drop. The thyristor is a semi-control device, which belongs to the first generation of products, but the modulation frequency is low, the control is complex, the power is low, the capacity is large, the voltage is high, and the history is long-lasting.

The application of GTO thyristors and BJTs, whether assembled DC choppers or assembled VFDs, has a monopoly in the application of GTO thyristors in electric locomotives. This is also a serious scientific research topic organized by China during the Eighth Five-Year Plan period. However, the use of GTO thyristor VFD for other centers is controversial because the turn-off current gain of GTO thyristor is too small, overcurrent maintenance is difficult, and the modulation frequency is low. DC choppers and PWMVFDs assembled with BJT are very popular, but the output voltage does not exceed 460V and the capacity does not exceed 400kW. BJT is a current drive, with high power consumption, low modulation frequency, and high noise, which is not as simple and reliable as the voltage drive of MOSFET. However, the latter has a smaller capacity and a lower output voltage, and there are not many competitive products in the market.

                               VFD center power electronics and control mode

In motion control, the new generation of power electronics are IGBT and MCT: the former is MOS-driven BJT, which has the advantage that the capacity and voltage exceed BJT, and there is a tendency to replace it; The latter MOS drives thyristors and theoretically has the advantages of both. These two new equipment have sophisticated products, IGBT has been developed to the fourth generation, and now foreign countries are transferring the consumption process of microelectronics to power electronics, so the production of application-specific integrated circuits (). The intelligent equipment that combines the drive circuit and maintenance circuit of the IGBT is called IPM, and the IPM that combines the switching power supply, so that the VFD is more reliable, and it has become the leading product of speed regulation in the past, which will replace DC speed regulation, and the 21st century will be the period of AC speed regulation.

2) Control methodVFD selects different control methods, with different speed adjustment functions, characteristics and uses. The control methods are broadly divided into open-loop and closed-loop control. Open-loop control includes a U/f (voltage and frequency) proportional control method; The closed loop includes slip frequency manipulation and various vector manipulations. From the perspective of the pre-development history, it is also from an open loop to a closed loop. The general vector control is comparable to the armature current control of a DC motor. Now the AC motor parameters can directly stop the direct torque control, which is convenient and accurate, and the control accuracy is high.

More on that
EMC Filter Installation Considerations – Delta EMC Filter Installation Considerations – Delta

All electronic equipment (including frequency converters) will generate some high-frequency or low-frequency noise during normal operation, and disturb the peripheral equipment through conduction or radiation. If the right EMC filter can be configured and the correct device method can be used, the disturbance can be reduced to a minimum. ...

Delta NT series UPS industrial power supply Delta NT series UPS industrial power supply

Delta's NT series UPS is a high-power UPS carefully discussed by experts for large-scale users, and a number of advanced skills have been selected, which can be used for various data processing systems, telecommunications systems, satellite systems, network systems, medical equipment, safety and emergency escape equipment, monitoring and security systems, and various industrial systems.

The inverter sets the characteristic parameters of the motor The inverter sets the characteristic parameters of the motor

1. Parameters to be set for the motor When the inverter (hereafter referred to as the -VFD) is operating in the "vector control" (F0-03=1) mode, it is highly dependent on accurate motor parameters, which is one of the important differences from the "VF controlled" (F0-03=2) mode. In order for the VFD to have outstanding driving ...

Introduction to the common sense of Delta inverter Introduction to the common sense of Delta inverter

The low-voltage fuse cannot be used as an overload maintenance for the motor. It is necessary that the additional voltage of the fuse is greater than or equal to the operating voltage of the distribution line. The additional current of the fuse must be greater than or equal to the additional current of the melt. ...

Set the parameters when reading and uploading the Delta PLC program Set the parameters when reading and uploading the Delta PLC program

Open Delta's programming software, and use WPLSOFT to do the demo here; First, click on the settings and then click on the communication settings in the settings, select the communication mode, communication port, communication baud rate, communication station number, etc. After the setting is finished, click OK to automatically close the pop-up window. In the dish ...

The inverter has a function – a Delta inverter The inverter has a function – a Delta inverter

1. Soft start is energy-saving The hard start of the motor will cause a serious impact on the power grid, and it will also require too high the capacity of the power grid, and the large current generated when the motor is started and the sensation will cause great damage to the baffle and valve, and the service life of the equipment and pipeline will be extremely unlucky. And the use of inverter energy-saving devices ...

Delta's active front-end and inverter's coordination Delta's active front-end and inverter's coordination

The popularity of frequency converters has brought significant energy savings to industrial applications. However, the high-frequency switching signal generated by the inverter is easy to cause electromagnetic interference and affect the power quality. Especially in industries with large loads such as lifting and elevators, it is becoming more and more obvious. ...

Delta's Smart series of micro-modules help transform high-speed tunnel networks Delta's Smart series of micro-modules help transform high-speed tunnel networks

Recently, Delta's Smart series of micro-modular data center processing solutions successfully assisted the smooth implementation of a provincial tunnel network transformation project in a province. The project has set up a series of safety operation networks such as video, lights, signals, networks, rescues, and alarms for the safe operation of key roads in the province.

Delta inverter braking resistor selection Delta inverter braking resistor selection

1. The necessity of braking resistance If the regenerative energy that occurs during deceleration and descent in the application is too large, there is a possibility that the voltage of the main circuit inside the inverter will rise, causing damage. Due to the built-in overvoltage maintenance function in the inverter, the overvoltage of the main circuit (O ...

The inverter needs to be equipped with a braking resistor-Delta The inverter needs to be equipped with a braking resistor-Delta

The inverter is equipped with a braking resistor, mainly to consume part of the energy on the DC bus capacitor through the braking resistor to avoid the voltage of the capacitor being too high. Theoretically, if the capacitor stores a lot of energy, it can be used to release it to drive the motor to avoid energy waste, but the capacity of the capacitor is limited.

Do Delta thermostats have a "slope control" function? Do Delta thermostats have a "slope control" function?

Delta's thermostats are only available in the DTE series (variety 1.5 and above) with the "slope control" function. Illustrate the following examples: For example: PV=20°C, SV=100°C, slope 10.0°C/min Then (100 – 20)/10.0 ...

Inverter optocoupler device type - Delta Inverter optocoupler device type - Delta

1. One is a triode type photocoupler, such as PC816, PC817, 4N35, etc., which is commonly used in the output voltage sampling and error voltage amplification circuit of the switching power supply circuit, and is also used in the digital signal input loop of the inverter control terminal. The structure is the simplest, and the input side consists of a light-emitting two...

Delta's A2 server maintenance location controller is faulty Delta's A2 server maintenance location controller is faulty

Delta's A2 series servo system is one of the more common and used servers on the market today, and the following describes the fault details of the azimuth controller in the repair of Delta's A2 servo drive and the corresponding repair methods Delta ...

The peripheral equipment of the inverter governor - Delta The peripheral equipment of the inverter governor - Delta

When installing the inverter governor, it is necessary to first understand its use occasions and set up different peripheral equipment according to the needs of the site. The primary peripheral equipment of frequency governor is: air circuit breaker, electromagnetic contactor, communication reactor, braking resistor, DC reactor, output communication reactor, wireless ...

Characteristics of common models of Delta inverters Characteristics of common models of Delta inverters

Delta MS300 Inverter Series: Delta's compact standard vector-operated inverter MS300 combines the advantages of miniaturization, high functionality, high trust, and simple installation, transforming every investment in industrial resources into abundant results. Optimized structure with lock-free screw terminals to plan the supply of bento ...

The inverter needs to prepare the braking resistance condition - Delta The inverter needs to prepare the braking resistance condition - Delta

The preparation of the braking resistor of the inverter is mainly to consume part of the energy on the DC bus capacitor through the braking resistor to prevent the capacitor voltage from being too high. Theoretically, if the capacitor stores a large amount of energy, it can be used to release it to drive the motor and prevent energy waste. However, the capacitance of the capacitor is ...

Delta launched an integrated control solution for layer winding Delta launched an integrated control solution for layer winding

As factories move from automation to intelligence, the requirements for equipment performance and scalability are progressing day by day. In response to the rapid development of electronic engineering, transportation and mechanical engineering and other occupations, in order to quickly manufacture related product parts and components, metal coil winding technology is also being carried out at a high speed.

Delta servo problem analysis Delta servo problem analysis

1: What is the difference between servo motor and general motor? The biggest difference between servo motors and general motors is the motor rotor and reaction equipment. The surface of the servo motor rotor is pasted with a strong magnetic plate, so that the magnetic field generated by the stator coil can control the orientation of the rotor, and the acceleration and deceleration characteristics are ...

Delta's key steps in inverter maintenance Delta's key steps in inverter maintenance

First, the maintenance of the inverter must first check whether the sound in the operation of the motor has changed abnormally, including, whether the motor is in operation to form a sensation. 2. Check whether the natural environment of the inverter installation has changed. For example, whether the operating temperature is normal. Learn more about Delta's inverter ...

Delta inverter password Delta inverter password

The inverter of Delta's brand A series locks the keypad to correct the parameters, forming that most of the parameters cannot be corrected, and the manual does not clearly explain how to unlock the keypad lock, press MODE and RESET together to display P256 (P256 does not explain what it means in the manual), press ENTER...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top