1. Parameters to be set for the motor
When the inverter (hereafter referred to as the -VFD) is operating in the "vector control" (F0-03=1) mode, it is highly dependent on accurate motor parameters, which is one of the important differences from the "VF controlled" (F0-03=2) mode. In order for the VFD to have outstanding driving function and operating power, the required motor parameters for the /kloc are (default motor 1 function code):
2. Automatic tuning and identification of motor parameters
The methods of VFD to obtain the internal electrical parameters of the controlled motor include dynamic identification, static identification, and manual input of motor parameters.
The steps for automatic adjustment of motor parameters are as follows:
The following takes the parameter identification method of motor 1 as an example to illustrate, which is the same as that of motor 2.
Step 1: If the motor can be completely separated from the load, in the event of a power failure, the motor is mechanically separated from the load and the motor is allowed to roll freely without load.
Step 2: After powering on, select the VFD command source (F0-04) as the command channel of the operation panel.
Step 3: Accurately enter the nameplate parameters of the motor (such as F4-01 - F4-06). Please press the motor actualparameters to enter the following parameters (according to the motor selection at the time):
Step 4: If it is an asynchronous motor, F4-00 (tuning and selection, for motor 2, it should be H1-00 function code). Please select 2 (Dynamic Full Tuning) and press Enter to confirm. At this moment, the keyboard appears:
Then press the RUN button on the panel, and the VFD will drive the motor to accelerate and decelerate, and run back and forth. The running indicator lights up, indicating that the running duration is about 2 minutes. When the above display information disappears, it will return to the normal parameter display state, indicating that the tuning is complete. After the adjustment, the VFD will automatically calculate the following parameters of the motor:
If the motor cannot be completely separated from the load, please select 1 (static tuning) for F4-00 (H1-00 for motor 2), and then press the RUN button on the panel to start identifying the motor parameters.
3. Set and switch the parameters of multiple sets of motors
It can be specified by the function code H0-00, or the motor parameter set that is useful at the time can be selected by the digital input terminal function 41. However, when the digital input terminal function 41 is useful, it takes precedence, and the H0-00 setting is invalid at the moment.
|
More on that
|
Delta UPS uninterruptible power supply R-2K series
With the increasing demand for system switching power supply by computer technology, Delta UPS uninterruptible power supply R-2K series products have been paid more and more attention, and gradually developed into a kind of electrical engineering with the effects of voltage stabilizer tube, frequency stabilization, filtration, anti-electromagnetic and frequency emission influence, anti-operation voltage swimming, etc.
|
|
How to use Delta's inverter operation
(1) When the speed of the motor is controlled by the Delta inverter, the noise and temperature rise of the motor are higher than that of the frequency of the motor. When the motor is running at low speed, because the speed of the motor blades is low, the temperature rise of the motor becomes high.
|
|
Solution to Delta inverter fault CE1 and CE2
Product range:
CP/CH/CT/C2000/C200/MS300/MH300/VE/ED/VJ
Problem Code:
CE1
Problem Description:
Communication is abnormal
Solution:
1. Communication error: RS-485 Modbus function code may be faulty
...
|
|
Replaced by discontinued models of Delta inverters
Delta's new generation of compact and efficient vector-controlled inverter MH300, adhering to the good driving function of Delta's inverter, has six advantages: compact size, flexible application, stable system, reliable quality, and easy installation.
|
|
Delta's power supply series application considerations
(1) Considering that the power supply is inconsistent at the time of power-on, the load is short-circuited, and the rational load may present a reverse voltage, the output end of each power supply connected in series should be set up with two anti-parallel tubes, and the forward additional current of the two * tubes should not be less than the additional output current of the power supply, and the reverse breakdown voltage should not be less than ...
|
|
Inverter wiring and parameter setting method - Delta
The inverter used in industry is divided into two types: single-phase and three-phase, which is distinguished from the voltage supplied by the main circuit, which is the main circuit to be connected to RST three-phase 380 volt alternating current, and the output is connected to the UVW three-phase line to the motor; And the single-phase is the main circuit connected to the single-phase 220 volt LN alternating current, the output is the same ...
|
|
Servo motor speed improvement method - Delta
When many engineers debug servo motors, they often have such a problem: why is my servo motor so slow, how can I improve the speed, and how much can the maximum speed reach? The basis for the confirmation of the speed method of the servo motor: the speed of the servo motor.
...
|
|
Comparison of three speed regulation methods for Delta DC motors
There are three speed regulation methods for DC motors: armature loop string resistance, armature voltage regulation and speed regulation, and weak magnetic field speed regulation. The three speed regulation methods can achieve stepless speed regulation.
1. Armature loop string resistance
The applied resistor is connected into the armature circuit to achieve the purpose of speed regulation.
Speed Direction: Add ...
|
|
DC motor speed regulation method - Delta
There are three speed regulation methods for DC motors: armature loop string resistance, armature voltage regulation and speed regulation, and weak magnetic field speed regulation. The three speed regulation methods can achieve stepless speed regulation.
1. Armature loop string resistance
The applied resistor is connected to the armature circuit.
|
|
The benefits of using an inverter – Delta inverter
1. Speed regulation of general motor: By changing the input voltage and frequency of the three-phase asynchronous motor, its speed can be controlled. Generally, when the motor is at low speed, the temperature rise becomes larger due to the decrease in the power of the cooling fan, and the motor load should be reduced according to the frequency.
2 ...
|
|
Method for measuring temperature rise during reducer operation - Delta
The thermometer method and resistance method can be used to measure the temperature rise of each part of the reducer.
1) Thermometer method: This is the easiest way to measure the temperature directly, and it is commonly measured by an alcohol thermometer. When measuring, the thermometer can be placed close to the ...
|
|
EMC Filter Installation Considerations – Delta
All electronic equipment (including frequency converters) will generate some high-frequency or low-frequency noise during normal operation, and disturb the peripheral equipment through conduction or radiation. If the right EMC filter can be configured and the correct device method can be used, the disturbance can be reduced to a minimum. ...
|
|
The inverter reported the cause of the grounding fault - Delta
Regarding the grounding problem, it can generally be swept away after the following steps (because most of the inverters are not easy to detect the current measurement of Hall components, it is very important to sweep the grounding caused by external conditions, and alternative methods can be selected if there are conditions, and it is still an external problem to change a normal load to see whether it is a problem of frequency conversion or an external problem ...
|
|
Detection methods for Delta circuit breakers, AC contactors and frequency converters
1. Circuit breaker
A circuit breaker is a device that can be manually or automatically controlled, and is used to control the on/off of the system power supply in the equipment circuit system. When there is a suspicion that there is a defect in the electrical system of the equipment, the primary functional part of the power supply should be checked.
Under normal circumstances, when in the ON state, the input input ...
|
|
The role and application of Delta's thermostats
Delta's thermostat is a commonly used temperature control device, which can adjust the temperature according to the user's needs, and then achieve the intention of saving energy. The effect and use of Delta thermostats are also very widespread, so let's introduce the effects and uses of Delta thermostats.
...
|
|
Introduction of high-power fan inverter - Delta
High power means increased cost
The use of high-power fan inverter can indeed meet the various production needs of enterprises, but high-power also means an increase in production costs. Because the more power, the more power will be consumed. Assuming that a 20KW fan inverter can ...
|
|
A number of Delta's new high-end power supply products were unveiled at CMEF
Delixi Electric's newly launched CDQ1F series PC-level excitation active transfer switch, with more complete specifications and stronger functions, the power-off time can be shortened to less than 0.1s, escorting the continuous use of electricity in important places!
CDQ1F Active ...
|
|
Important parameters of Delta inverters
The inverter is the pioneering work of Delta Automation, and it is also the largest selling product of Delta Automation. In the highly competitive market, Delta inverters have always maintained a strong growth momentum and made great achievements in the high-end product market and the economic product market. Delta continues to launch high-end products ...
|
|
Use and maintenance of electric motors - Delta motors
The motor can be started after the work is completed before use, and attention should be paid to the investigation of the motor, transmission device, production machinery and line voltage and ammeter, if there is an abnormal phenomenon, it should be stopped immediately, the fault should be identified and swept away, and then it can be closed and started again.
When the motor is running, ...
|
|
Problems with Delta's compact pressure transmitters
1. The transmitter does not return to zero under no pressure?
Answer: The cleaning method is to remove the transmitter from the device position, investigate whether the zero position is normal, and replace the pipeline sealing ring if it is normal. Check together whether the transmitter is perpendicular to the piping assembly, and if not, adjust the transmitter zero.
...
|
|