Megmeet inverter - what are the main aspects of the development of inverter in the future?

Create Date: 2024-8-30 12:03:23|Source: MEGMEET

1. Intelligent network

The intelligent inverter does not need to set a lot of parameters when it is used, and it has the function of fault self-diagnosis, which has high stability, high reliability and practicability. The Internet can be used to realize the linkage of multiple inverters, and even the integrated management and control system of inverters in the factory.

The intelligent inverter does not need to set a lot of parameters when it is used, and it has the function of fault self-diagnosis, which has high stability, high reliability and practicability. The Internet can be used to realize the linkage of multiple inverters, and even the integrated management and control system of inverters in the factory.

2. Specialization and integration

The manufacturing specialization of the inverter can make the performance of the inverter stronger in a certain field, such as the inverter for fans and pumps, the special inverter for elevators, the special inverter for lifting machinery, the special inverter for tension control, etc. In addition, the inverter has a tendency to be integrated with the motor, so that the inverter becomes a part of the motor, which can make the volume smaller and the control more convenient.

3. Energy saving, environmental protection and pollution-free

Protecting the environment and manufacturing "green" products is a new concept for human beings. The power drive device should focus on energy saving and low pollution in the energy conversion process of the inverter, so that the noise of the inverter in the process of use, the pollution of power harmonics to the power grid and other problems are reduced to a minimum.

4. Adapt to new energy

Fuel cells, powered by solar and wind power, are now emerging at a low price and are likely to catch up. The biggest feature of these power generation equipment is that the capacity is small and scattered, and the future inverter will have to adapt to such new energy, which must be both efficient and low consumption. Now power electronics technology, microelectronics technology and modern control technology are developing at an astonishing speed, and the frequency conversion speed regulation transmission technology has also made rapid progress, which is mainly reflected in the large capacity of AC speed control device, the high performance and multi-function of the frequency converter, and the miniaturization of the structure.
Megmeet inverter - what are the main aspects of the development of inverter in the future?

More on that
Megmeet welding machines – the main application area of resistance welding Megmeet welding machines – the main application area of resistance welding

(1) Spot welding: The weldment is pressed between the two cylindrical electrodes, heated by electricity, so that the weldment melts at the contact to form a nugget, and then the power is cut off, and it solidifies and crystallizes under pressure to form a dense solder joint. Spot welding is suitable for welding thin plates (laps) and steel bars below 4 mm.

Megmeet inverters – what do you need to pay attention to when choosing the power of the inverter? Megmeet inverters – what do you need to pay attention to when choosing the power of the inverter?

The system efficiency is equal to the product of the efficiency of the inverter and the efficiency of the motor, and the system efficiency is higher only when both are working at higher efficiency. From the perspective of efficiency, the following points should be paid attention to when selecting the power of the inverter: 1) Inverter power value and motor power ...

Megmeet inverter - the fault handling method of low-voltage inverter Megmeet inverter - the fault handling method of low-voltage inverter

Before using the inverter, the inverter parameters should be carried out from the following aspects: First, confirm the motor parameters, the inverter sets the power, current, voltage, speed, and maximum frequency of the motor in the parameters, and these parameters can be directly obtained from the motor nameplate. Clause...

Megmeet PLC - What places should be avoided when installing PLC control? Megmeet PLC - What places should be avoided when installing PLC control?

(1) The ambient temperature exceeds the range of 0-50 °C; (2) The relative humidity exceeds 85% or there is dew condensation (caused by sudden temperature changes or other factors); (3) direct sunlight; (4) There are corrosive and flammable gases, such as hydrogen chloride, ...

Megmeet welding machine - an introduction to the advantages and disadvantages of resistance welding Megmeet welding machine - an introduction to the advantages and disadvantages of resistance welding

Advantages of resistance welding: 1。 When a nugget is formed, it is always surrounded by a ring of plastic, the molten metal is isolated from the air, and the metallurgical process is simple 2。 The heating time is short, the heat is concentrated, the heat affected zone is small, and the deformation and stress are small. In general, there is no need to arrange calibration and heat after welding.

Megmeet inverter - over-temperature protection for common fault analysis and treatment of inverter Megmeet inverter - over-temperature protection for common fault analysis and treatment of inverter

1. Over-temperature protection of inverter and its necessity The temperature protection function of the inverter is an indispensable condition to ensure the stable operation of the inverter; In the main circuit power device of the inverter, the rectifier bridge and the inverter bridge are semiconductor power devices.

Megmeet PLC - What are the five stages of the PLC work process? Megmeet PLC - What are the five stages of the PLC work process?

1. Common processing: reset the monitoring timer, perform hardware checks, user memory checks, etc. 2. Program execution: The CPU interprets and executes each instruction in the order of first left and then right, first up and then down, and reads out each relay according to the input image register and the component image register.

Megmeet inverter - high-voltage inverter selection considerations Megmeet inverter - high-voltage inverter selection considerations

First, the disadvantages Choosing too high a voltage level results in too high an investment and a long payback period. With the increase of the voltage level, the insulation of the motor must be improved, so that the price of the motor increases. The increase of voltage level increases the number of series connections of power semiconductor devices in the inverter, and the cost rises. ...

Megmeet inverter - common faults and treatment methods of high-voltage inverters Megmeet inverter - common faults and treatment methods of high-voltage inverters

The high-voltage inverter has a highly intelligent computing level and a perfect fault detection circuit, and can provide accurate positioning of all faults, and make clear instructions on the main control interface. In practical application, we find that common faults can be divided into abnormal control channels, IGBT overcurrent, overvoltage...

Megmeet PLC maintenance and processing methods Megmeet PLC maintenance and processing methods

1. CPU abnormality: When the CPU is abnormally alarmed, check the device connected to the internal line of the CPU unit. The specific method is to replace the units that may cause failures in turn, find out the faulty units, and deal with them accordingly. 2. Memory abnormality: When the memory is abnormal alarm, if it is a program ...

Megmeet MC100 series plc – the right hand man in refrigeration equipment Megmeet MC100 series plc – the right hand man in refrigeration equipment

First, the process requirements When the low-pressure pressure collected by the system is greater than the upper low-pressure pressure set by the touch screen, the compression time will be loaded according to the set loading time, and the lower pressure will be reduced according to the set load reduction time. The high pressure collected is greater than that on the high pressure ...

Megmeet PLC - the basic composition of PLC Megmeet PLC - the basic composition of PLC

a. Power supply The power supply of the PLC plays a very important role in the whole system. It can't work properly without a good and reliable power supply system, so PLC manufacturers also attach great importance to the design and manufacture of power supplies. General AC voltage fluctuations are +10% (+15%) ...

Megmeet PLC maintenance inspection Megmeet PLC maintenance inspection

PLC maintenance and inspection steps: 1. Check and make sure the mains power is on (120 VAC) 2. Check the available 24V power supply 3. Identify problem areas. It is recommended that peak currents cover this error code, a control method consisting of multiple components distributed over an area or process.

Megmeet inverter – the energy-saving principle of low-voltage inverter Megmeet inverter – the energy-saving principle of low-voltage inverter

Inverter energy saving The energy saving of the inverter is mainly manifested in the application of fans and pumps. In order to ensure the reliability of production, all kinds of production machinery are designed with power drive, and there is a certain amount of surplus. When the motor cannot operate at full load, in addition to meeting the power drive requirements, ...

Megmeet PLC common faults Megmeet PLC common faults

1. External equipment failure. Such faults come from external devices such as various sensors, switches, actuators, and loads. The failure of this part of the equipment will directly affect the control function of the system. This type of failure is usually caused by the quality and longevity of the equipment itself. 2. System failure ...

Megmeet Inverter - Summary of Common Faults of High Voltage Inverter (21-32) Megmeet Inverter - Summary of Common Faults of High Voltage Inverter (21-32)

21。 The unit is overheating The radiator in the unit is equipped with a temperature switch (normally closed point), and when the temperature exceeds 85°C, the normally closed point of the temperature relay is disconnected, and the unit is overheated and faulty. Check whether the cabinet top fan is working properly, whether the unit cabinet fan switch is tripped, and whether the filter screen is blocked.

Maintenance method of Megmeet PLC Maintenance method of Megmeet PLC

1. The electrical control cabinet installed with PLC should have a clean and dry environment. Moisture-absorbing dry materials should be placed inside, and the splashing of coolant and oil mist should be prevented. 2. Regardless of the system working or shutdown, the electrical cabinet door should always be closed, and the electrical components should be kept in a good state.

Megmeet PLC - Introduction to the basic structure of PLC controller Megmeet PLC - Introduction to the basic structure of PLC controller

1. Power supply The power supply of the PLC plays a very important role in the whole system. It can't work properly without a good and reliable power supply system, so PLC manufacturers also attach great importance to the design and manufacture of power supplies. General AC voltage fluctuations are +10% (+15%) ...

Common faults and solutions of Megmeet inverter Common faults and solutions of Megmeet inverter

1. Leakage protection switch Phenomenon: The leakage protection switch of the equipment is activated when the inverter is powered on or running Measures: When the inverter drives the motor, the leakage value is larger than that of the non-inverter system, and the leakage protection value of the leakage protection switch is required to be 150mA and above, and the action delay is ...

Megmeet drives – the replacement steps for high-voltage drive power units Megmeet drives – the replacement steps for high-voltage drive power units

1) Shut down, so that the inverter out of the operating state; 2) Cut off the high-voltage power supply and push out the high-voltage cabinet trolley (when there is a bypass cabinet. The inverter can be isolated by the disconnecting switch of the bypass cabinet), the local or remote high-voltage disconnect switch can be locked, and the high-voltage cabinet grounding switch can be grounded; 3) Hit ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top