Megmeet PLC – The importance of PLC industrial gateways

Create Date: 2024-8-30 12:03:23|Source: MEGMEET

1. Realize remote control of industrial field equipment;

2. The PLC industrial gateway realizes remote upgrade of equipment firmware, downloads the program, and can flexibly access various equipment management platforms;

3. Realize remote control of industrial site touch screen and remote mapping of configuration screens;

4. The PLC industrial gateway can communicate remotely with multiple PLCs or touch screens at the same time;

5. Realize the hardware analysis of mainstream protocols such as Siemens, Mitsubishi, Omron, Schneider, Delta, Inovance, Hollysys, Panasonic, Yonghong, Haiwei and MODBUS series;

6. The PLC industrial gateway realizes PLC remote monitoring, PLC remote programming, PLC remote debugging, PLC remote download, PLC remote control, PLC data acquisition, and PLC remote communication.
Megmeet PLC – The importance of PLC industrial gateways

More on that
Megmeet drives – the replacement steps for high-voltage drive power units Megmeet drives – the replacement steps for high-voltage drive power units

1) Shut down, so that the inverter out of the operating state; 2) Cut off the high-voltage power supply and push out the high-voltage cabinet trolley (when there is a bypass cabinet. The inverter can be isolated by the disconnecting switch of the bypass cabinet), the local or remote high-voltage disconnect switch can be locked, and the high-voltage cabinet grounding switch can be grounded; 3) Hit ...

Megmeet welding machine - failure and maintenance method of DC welding machine Megmeet welding machine - failure and maintenance method of DC welding machine

1. Fault phenomenon: light voltage abnormal indicator Cause: Due to the slow start-up action, the switch contact is not synchronized. Solution: You can turn the device off and on again. 2. Fault phenomenon: the fan does not rotate, and the abnormal voltage indicator light is lit together Causes ...

Megmeet PLC – Analysis of common failures of PLC Megmeet PLC – Analysis of common failures of PLC

1. The CPU is abnormal When the CPU is abnormally alarmed, check all the devices connected to the internal bus of the CPU unit. The specific method is to replace the potentially problematic units sequentially, find out the problematic units, and deal with them accordingly. Second, the memory is abnormal Memory anomaly alarm ...

Analysis of the fault code of Megmeet welder Analysis of the fault code of Megmeet welder

1. E1: indicates sensor failure. In this case, it is necessary to check whether the sensors of Megmeet are damaged or whether the wiring is loose. 2. E2: Indicates overweight load. At this point, it is necessary to check whether the load of Megmeet exceeds the set maximum load. 3. E3: Indicates battery ...

Megmeet PLC - What places should be avoided when installing PLC control? Megmeet PLC - What places should be avoided when installing PLC control?

(1) The ambient temperature exceeds the range of 0-50 °C; (2) The relative humidity exceeds 85% or there is dew condensation (caused by sudden temperature changes or other factors); (3) direct sunlight; (4) There are corrosive and flammable gases, such as hydrogen chloride, ...

Megmeet PLC - What is the difference between PLC and servo control system Megmeet PLC - What is the difference between PLC and servo control system

1. The meaning of the representation is different: PLC is the abbreviation of planar optical waveguide (technology), the so-called planar optical waveguide, means that the optical waveguide is located in a plane. A servo control system is a feedback control system used to accurately follow or reproduce a certain process.

Megmeet PLC – the three programming languages of PLC Megmeet PLC – the three programming languages of PLC

1. The ladder diagram language is the most commonly used programming language in PLC programming. The CPU reads physical input into a memory table, often referred to as an "input table". The form is evaluated for use in the procedure. Different platforms, using different types of registers; In each scan cycle, follow from left to right, ...

Megmeet PLC - the difference between PLC and frequency converter Megmeet PLC - the difference between PLC and frequency converter

1. The role is different A PLC (Programmable Logic Controller) is an electronic system designed for digital operations in an industrial environment. The inverter is the application of frequency conversion technology and microelectronics technology to control the AC motor by changing the frequency of the motor working power supply.

Megmeet drive common fault repair methods Megmeet drive common fault repair methods

When the oscilloscope looks at the current monitoring output of the driver, it is all noisy and cannot be read Cause: The current monitoring output is not blocked from the AC power supply (transformer). Solution: You can use a DC voltmeter to detect and investigate. Servo motor high-speed rotation ...

Megmeet drives – what are the benefits of using drives? Megmeet drives – what are the benefits of using drives?

1. Energy saving of frequency conversion speed regulation 1) Due to the use of frequency conversion speed regulation, the energy-saving effect of fans and pump loads is the most obvious, and the power-saving rate can reach 20%-60%, this is because the power consumption of the fan pump is proportional to the cubic of the speed.

Various welding methods for Megmeet welding machines Various welding methods for Megmeet welding machines

1) Hand arc welding (STICK) Shielded Arc Welding (abbreviated SMAW) in English, The principle is: the arc occurs between the coating electrode and the base metal, and the welding method of arc thermal ablation electrode and base metal is used. The outer layer of the electrode is covered with solder, which is dissipated in case of heat.

Megmeet inverter – three ways to connect the PLC to the inverter Megmeet inverter – three ways to connect the PLC to the inverter

(1) Use the analog output module of PLC to control the analog output module of the inverter The analog output module of the PLC outputs 0-5V voltage signal or 4-20mA current signal, which is used as the analog input signal of the inverter to control the output frequency of the inverter. This control method is simple to wiring, but it needs to be selected and changed.

Megmeet inverter – failure analysis of air compressor inverter Megmeet inverter – failure analysis of air compressor inverter

1. The voltage is unstable In the process of using the inverter air compressor, sometimes the voltage is unstable. If the voltage is unstable, a load may occur, causing the compressor to not start properly. Solution: The regulator can be adjusted in time. 2. The main ...

Megmeet servo drive - common faults and treatment methods of servo drives Megmeet servo drive - common faults and treatment methods of servo drives

1. The motor runs differently in both directions Cause of failure: The phase of the brushless motor is wrong; The deviation potentiometer is in the wrong position. Solution: Detect or detect the correct phase; Reposition the potentiometer. 2. The motor speed is abnormal Cause of failure ...

Megmeet drives – routine and regular maintenance of drives Megmeet drives – routine and regular maintenance of drives

1. Maintenance items and scope: Daily maintenance and maintenance of inverter Due to the influence of environmental temperature, humidity, dust and vibration, it will lead to the aging of the internal components of the inverter, resulting in the potential failure of the inverter or reducing the service life of the inverter. Therefore, there is a must ...

Megmeet inverter – the difference between voltage type inverter and current type inverter Megmeet inverter – the difference between voltage type inverter and current type inverter

1. The load of the buffer inverter without functional quantity is an asynchronous motor, which is an inductive load, and in addition to transmitting active power between the intermediate DC link and the motor, there is also the exchange of reactive power. Since the power electronic switching devices cannot be stored for energy, the non-functional energy can only rely on the energy storage elements (filters).

Megmeet PLC maintenance inspection Megmeet PLC maintenance inspection

PLC maintenance and inspection steps: 1. Check and make sure the mains power is on (120 VAC) 2. Check the available 24V power supply 3. Identify problem areas. It is recommended that peak currents cover this error code, a control method consisting of multiple components distributed over an area or process.

Megmeet Inverter - Summary of Common Faults of High Voltage Inverter (21-32) Megmeet Inverter - Summary of Common Faults of High Voltage Inverter (21-32)

21。 The unit is overheating The radiator in the unit is equipped with a temperature switch (normally closed point), and when the temperature exceeds 85°C, the normally closed point of the temperature relay is disconnected, and the unit is overheated and faulty. Check whether the cabinet top fan is working properly, whether the unit cabinet fan switch is tripped, and whether the filter screen is blocked.

Megmeet Inverter - Summary of Common Faults of High Voltage Inverter (11-20) Megmeet Inverter - Summary of Common Faults of High Voltage Inverter (11-20)

11。 If the interface board does not communicate with the monitor and does not establish communication with the interface board, the interface board will reset the monitor every 5 seconds, and if the communication is not established within 3 minutes and 30 seconds, it will be judged as a serious fault. Whether the communication line is normal, check whether the terminal is correct; Whether the I/O board is working properly. Especially the work ...

Megmeet PLC – How does PLC communicate with computers? Megmeet PLC – How does PLC communicate with computers?

1. In this computer, right-click, manage, check to find the device manager, plug in the USB-PPI cable (one end is connected to the computer, the other end is connected to the PLC), the computer device manager will pop up the port USB-SERLAL CH304 (com3), the number in parentheses may change, indicating that you have found the cable. This...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top