1. Power supply
The power supply of the PLC plays a very important role in the whole system. It can't work properly without a good and reliable power supply system, so PLC manufacturers also attach great importance to the design and manufacture of power supplies. Generally, the AC voltage fluctuates in the range of +10% (+15%), and the PLC can be connected directly to the AC grid without other measures
2. Central Processing Unit (CPU)
The central processing unit (CPU) is the control center of the PLC. It receives and stores the user program and data typed from the programmer in accordance with the functions given by the PLC system program; Check the status of power, memory, I/O, and alert timers, and diagnose syntax errors in user programs. When the PLC is put into operation, first it receives the status and data of each input device in the field in the form of scanning, and stores them in the I/O image area respectively, and then reads the user program one by one from the user program memory, and sends the results of logic or arithmetic operation according to the provisions of the instruction into the I/O image area or data register after the command interpretation. After all user programs have been executed, the output status of each I/O image area or the data in the output registers is transferred to the corresponding output device, and so on until the operation is stopped.
In order to further improve the reliability of PLCs, in recent years, large-scale PLCs have been used to form a redundant system with two CPUs, or a voting system with three CPUs. This way, even if one CPU fails, the entire system will still function normally.
3. Memory: The memory that stores the system software is called the system program memory; The memory that holds the application software is called the user program memory.
4. Input and output interface circuits
(1) The field input interface circuit consists of the optocoupler circuit and the input interface circuit of the microcomputer, which is the input channel of the interface interface between the PLC and the field control.
(2) The field output interface circuit is integrated by the output data register, the strobe circuit and the interrupt request circuit, and the PLC outputs the corresponding control signal to the execution component in the field through the field output interface circuit.
(3) Functional modules: such as counting, positioning and other functional modules.
(4) Communication module: such as Ethernet, RS485, Profibus-DP communication module, etc.
|
More on that
|
Megmeet PLC - the core components of PLC introduction
(1) Central Processing Unit (CPU)
The central processing unit (CPU) is the control center of the PLC. It accepts and stores user programs and data typed from the programmer, checks the status of the power supply, memory, I/O and alert timer in accordance with the functions assigned by the PLC system program, ...
|
|
Megmeet Inverter - Precautions for the Use of Inverter (1-10)
1. The inverter must be selected correctly.
2. Read the product manual carefully, and wiring, installation and use in accordance with the requirements of the manual.
3. The inverter device should be reliably grounded, and the radio frequency interference should be suppressed to prevent the inverter from causing electric shock due to leakage.
4、 ...
|
|
Megmeet welding machine – the main feature of the laser welding machine
(1) The energy density is highly concentrated, the heating and cooling speed is extremely fast during welding, the heat affected zone is small, and the welding stress and deformation are very small;
(2) Non-touch processing, no external force on the weldment, suitable for welding parts that are difficult to touch;
(3) The laser can be transmitted through the optical incoming ...
|
|
Maintenance inspection of Megmeet inverters
1. The Megmeet rectifier module is damaged
It is usually caused by grid voltage or internal short circuit. In the case of sweeping the internal short circuit, the rectifier bridge is replaced. When dealing with faults on site, we should focus on checking the status of the user's power grid.
Such as the power grid voltage, whether there is an electric welding machine, etc.
|
|
Megmeet PLC – 10 PLCs integrated failure analysis
1. Grounding problems
The grounding requirements of the PLC system are relatively strict, and it is best to have an independent dedicated grounding system, and it should also be noted that other equipment related to PLC should also be reliably grounded.
When multiple circuit grounding points are connected together, unexpected currents can be generated, resulting in logic errors or ...
|
|
Megmeet inverter - 5 precautions for the use of inverter
1. The circuit board inside the inverter belongs to precision electronic components, which needs to be moisture-proof and dust-proof, and the temperature and humidity are not too high, and cannot be installed on the bare wall, so the inverter should be installed in the middle of the control cabinet; The inverter should be installed vertically, and the installation should be avoided directly above and below ...
|
|
Megmeet drives – the design essentials of the drive control cabinet
The inverter should be installed inside the control cabinet, and the design of the control cabinet should pay attention to the following issues:
1. Wiring specification of inverter
The signal line and the power line must be separated: When using an analog signal to remotely control the inverter, in order to reduce the interference of the analog signal to equipment such as the inverter, ...
|
|
Welding methods for Megmeet hand arc welding and MIG/MAG welding
1) Hand arc welding (STICK)
Shielded Arc Welding (abbreviated SMAW) in English,
The principle is: the welding method of generating an electric arc between the coating electrode and the base metal, and using the arc heat to melt the electrode and the base metal. The outer layer of the electrode is covered with solder, and it melts when heated.
|
|
Megmeet Inverter - Summary of Common Faults of High Voltage Inverter (21-32)
21。 The unit is overheating
The radiator in the unit is equipped with a temperature switch (normally closed point), and when the temperature exceeds 85°C, the normally closed point of the temperature relay is disconnected, and the unit is overheated and faulty.
Check whether the cabinet top fan is working properly, whether the unit cabinet fan switch is tripped, and whether the filter screen is blocked.
|
|
Megmeet welding machine - introduction to the advantages and disadvantages of carbon dioxide gas shielded welding
Carbon dioxide gas shielded welding (referred to as CO2 welding) is the use of CO2 gas as the maintenance medium, during welding, CO2 gas is sprayed out through the nozzle of the welding gun, along the perimeter of the welding wire, forming a gas maintenance layer around the arc, mechanically isolating the welding arc and the molten pool from the air, and then avoiding ...
|
|
Introduction to Megmeet welding machine
The EhaveCM350AR is a fully digital inverter melting multi-functional industrial heavy-duty Megmeet welding machine launched by Megmeet for global metalworking manufacturing. It brings customers higher quality and higher efficiency welding experience and value with excellent arc characteristics, reliability and high efficiency, and helps customers ...
|
|
Megmeet welding machine - resistance welding or laser soldering who is more suitable for electronics industry applications
Today's electronics industry revolves around high-speed communication and supercomputing on the Internet, and the requirements for electronic products are getting higher and higher. A large number of micro-precision electronic products are constantly testing the response speed and level of major enterprises in the market. Electronics manufacturers perform real-time, accurate ...
|
|
Hollysys' nationally produced SCADA system was the first to be put into application in the refined oil pipeline network of National Petroleum Pipeline Network Group Co., Ltd
Preface:
Energy security is an overall and strategic issue related to the country's economic and social development, and is crucial to the country's prosperity and development, the improvement of people's lives, and the long-term peace and stability of society. For the first time, the 14th Five-Year Plan and the Outline of the Long-Range Objectives Through 2035 include "comprehensive energy production capacity" in the ...
|
|
Megmeet servo drive - common faults and treatment methods of servo drives
1. The motor runs differently in both directions
Cause of failure: The phase of the brushless motor is wrong; The deviation potentiometer is in the wrong position.
Solution: Detect or detect the correct phase; Reposition the potentiometer.
2. The motor speed is abnormal
Cause of failure ...
|
|
Megmeet Inverter - Summary of Common Faults of High Voltage Inverter (1-10)
1。 How do you distinguish between heavy and light failures?
When the fault is light, the system sends out an alarm signal, and the fault indicator flashes. When a major fault occurs, the system issues a fault indication, and the fault indicator is always on. At the same time, a command is issued to break the high voltage and close the prohibition, and the fault information and high voltage are instructed.
|
|
New Arrivals! Hollysys' two blockbuster products were unveiled at the Zhongguancun Forum Technology Trading Conference
On September 24, the 2021 Zhongguancun Forum, co-sponsored by the Ministry of Science and Technology of China, the Chinese Academy of Sciences, the China Association for Science and Technology, and the Beijing Municipal People's Government, officially opened in Beijing. As one of the main agendas of the forum, the Zhongguancun International Technology Exchange Conference closely follows the "smart· healthy· carbon neutrality...
|
|
Megmeet inverter - common faults and treatment methods of high-voltage inverters
1. Control through this abnormal failure
The abnormal fault of the control channel is usually caused by the optical fiber communication between the sub-PWM board and the power unit board, which is generally caused by the following situations:
1. Poor contact of the optical fiber connection part or falling off of the optical fiber head;
2. Optical fiber signal transmitter/receiver ...
|
|
Megmeet inverter - over-temperature protection for common fault analysis and treatment of inverter
1. Over-temperature protection of inverter and its necessity
The temperature protection function of the inverter is an indispensable condition to ensure the stable operation of the inverter; In the main circuit power device of the inverter, the rectifier bridge and the inverter bridge are semiconductor power devices.
|
|
Megmeet drives – what are the basic requirements for regular replacement of drive components?
1. It is necessary to figure out the basic parameters and shape of the device that needs to be replaced. The basic parameters include the rated operating current, the capacitance of the capacitor, the resistance value of the resistor, the value of the GTR Darlington device (current amplification factor), the switching characteristics of the IGBT (including IPM) device, and the saturation voltage ...
|
|
Megmeet inverter mv600 alarm code ENOC2
1. If there is a sharp acceleration or deceleration, please extend the acceleration and deceleration time.
2. Avoid rapid increase in load.
3. Check whether there is a short circuit in the UVW of the motor terminal.
4. The module is damaged, and the drive circuit is damaged, resulting in an overcurrent alarm.
...
|
|