Megmeet inverter - precautions for inverters at high temperatures

Create Date: 2024-8-30 12:03:23|Source: MEGMEET

1. Carefully monitor and record the display parameters on the man-machine interface of the inverter, and reflect the abnormality immediately;

2. Carefully monitor and record the ambient temperature of the frequency conversion room, and the ambient temperature should be between -5 °C and 40 °C. The temperature rise of the phase-shifting transformer should not exceed 130°C;

3. When the temperature is high in summer, the ventilation and heat dissipation of the inverter installation site should be strengthened. Ensure that the ambient air is free of excessive amounts of dust, acids, salts, corrosive and explosive gases;

4. Summer is a rainy season, and rainwater should be prevented from entering the inverter (such as rainwater entering the air outlet along the air channel);

5. The filter screen on the inverter cabinet door should usually be cleaned once a week; If the working environment is dusty, the cleaning interval should also be shortened according to the actual situation;

6. During the normal operation of the inverter, a piece of A4 paper of standard thickness should be firmly adsorbed on the filter screen of the air inlet of the cabinet door;

7. The frequency conversion room must be kept clean and tidy, and should be cleaned at any time according to the actual situation of the site;

8. The ventilation and lighting of the frequency conversion room must be good, and the ventilation and heat dissipation equipment (air conditioning, ventilation fan, etc.) can operate normally.
Megmeet inverter - precautions for inverters at high temperatures

More on that
Megmeet PLC – the three output types of PLC Megmeet PLC – the three output types of PLC

The first is relay output, the relay output response speed is slow, the output current is large, generally can reach 2A, but the electric shock life is short, the output frequency is low, the maximum is 1HZ; The second is transistor output, the transistor output response speed is fast, the output current is small, and the contact life is relatively small.

Solutions to common faults of Megmeet inverter (2) Solutions to common faults of Megmeet inverter (2)

Fault three Fault phenomenon: There is a rebound phenomenon when the rotation starts Solution: 1. Set the start frequency P08.02 and start frequency time P08.03 appropriately (such as P08.02=P08.03=0.5) 2. Appropriately reduce the stator resistance (P03.07) and no-load current value (P03.11 ...

Common faults and solutions of Megmeet PLC Common faults and solutions of Megmeet PLC

1. Do not execute the program: The input check is identified by the input LED indicator or the input monitor composed of a writer. When the input LED is not lit, it can be preliminarily determined that the external input system is faulty, and then check with the multimeter. If the output voltage is not normal, it can be determined that ...

Megmeet PLC – Analysis of common failures of PLC Megmeet PLC – Analysis of common failures of PLC

1. The CPU is abnormal When the CPU is abnormally alarmed, check all the devices connected to the internal bus of the CPU unit. The specific method is to replace the potentially problematic units sequentially, find out the problematic units, and deal with them accordingly. Second, the memory is abnormal Memory anomaly alarm ...

Megmeet inverter - maintenance precautions and items for high-voltage inverters Megmeet inverter - maintenance precautions and items for high-voltage inverters

Precautions for maintenance of high-voltage inverters 1. Carefully monitor and record the display parameters on the man-machine interface of the inverter, and reflect the abnormality immediately 2. Carefully monitor and record the ambient temperature of the inverter room, and the ambient temperature should be between -5 °C and 40 °C. Phase-shifting transformers ...

Megmeet PLC - an introduction to the classification of PLC Megmeet PLC - an introduction to the classification of PLC

There are many types of PLC products, and their specifications and performance also vary. PLCs are usually classified according to their different structural forms, differences in functions, and the number of I/O points. 2.1 Classification by structural form According to the structural form of PLC, PLC can be divided into whole ...

Megmeet inverter – failure analysis of air compressor inverter Megmeet inverter – failure analysis of air compressor inverter

1. The voltage is unstable In the process of using the inverter air compressor, sometimes the voltage is unstable. If the voltage is unstable, a load may occur, causing the compressor to not start properly. Solution: The regulator can be adjusted in time. 2. The main ...

Megmeet inverter – the difference between voltage type inverter and current type inverter Megmeet inverter – the difference between voltage type inverter and current type inverter

1. The load of the buffer inverter without functional quantity is an asynchronous motor, which is an inductive load, and in addition to transmitting active power between the intermediate DC link and the motor, there is also the exchange of reactive power. Since the power electronic switching devices cannot be stored for energy, the non-functional energy can only rely on the energy storage elements (filters).

Analysis of the fault code of Megmeet welder Analysis of the fault code of Megmeet welder

1. E1: indicates sensor failure. In this case, it is necessary to check whether the sensors of Megmeet are damaged or whether the wiring is loose. 2. E2: Indicates overweight load. At this point, it is necessary to check whether the load of Megmeet exceeds the set maximum load. 3. E3: Indicates battery ...

Megmeet inverter - inverter braking mode and advantages and disadvantages introduction Megmeet inverter - inverter braking mode and advantages and disadvantages introduction

What are the braking methods of the inverter? Generally speaking, braking refers to the technical measures taken during the operation of the motor due to fault protection or man-made active shutdown, and the commonly used inverter braking methods include energy consumption braking, feedback braking, DC braking and DC feedback braking. ...

Megmeet drives – what are the benefits of using drives? Megmeet drives – what are the benefits of using drives?

1. Energy saving of frequency conversion speed regulation 1) Due to the use of frequency conversion speed regulation, the energy-saving effect of fans and pump loads is the most obvious, and the power-saving rate can reach 20%-60%, this is because the power consumption of the fan pump is proportional to the cubic of the speed.

Megmeet welding machine - resistance welding or laser soldering who is more suitable for electronics industry applications Megmeet welding machine - resistance welding or laser soldering who is more suitable for electronics industry applications

Today's electronics industry revolves around high-speed communication and supercomputing on the Internet, and the requirements for electronic products are getting higher and higher. A large number of micro-precision electronic products are constantly testing the response speed and level of major enterprises in the market. Electronics manufacturers perform real-time, accurate ...

Megmeet inverter - over-temperature protection for common fault analysis and treatment of inverter Megmeet inverter - over-temperature protection for common fault analysis and treatment of inverter

1. Over-temperature protection of inverter and its necessity The temperature protection function of the inverter is an indispensable condition to ensure the stable operation of the inverter; In the main circuit power device of the inverter, the rectifier bridge and the inverter bridge are semiconductor power devices.

Megmeet PLC - the core components of PLC introduction Megmeet PLC - the core components of PLC introduction

(1) Central Processing Unit (CPU) The central processing unit (CPU) is the control center of the PLC. It accepts and stores user programs and data typed from the programmer, checks the status of the power supply, memory, I/O and alert timer in accordance with the functions assigned by the PLC system program, ...

Megmeet PLC – 10 PLCs integrated failure analysis Megmeet PLC – 10 PLCs integrated failure analysis

1. Grounding problems The grounding requirements of the PLC system are relatively strict, and it is best to have an independent dedicated grounding system, and it should also be noted that other equipment related to PLC should also be reliably grounded. When multiple circuit grounding points are connected together, unexpected currents can be generated, resulting in logic errors or ...

Megmeet inverter - heat dissipation design considerations for high-power high-voltage inverters Megmeet inverter - heat dissipation design considerations for high-power high-voltage inverters

(1) Select components and materials with good heat resistance and thermal stability to increase their allowable working temperature; (2) Reduce the heat generated inside the equipment (device). To this end, micropower devices, such as low-loss IGBTs, should be used more often, and the number of heat-generating components should be minimized in the circuit design.

Megmeet PLC - the basic composition of PLC Megmeet PLC - the basic composition of PLC

a. Power supply The power supply of the PLC plays a very important role in the whole system. It can't work properly without a good and reliable power supply system, so PLC manufacturers also attach great importance to the design and manufacture of power supplies. General AC voltage fluctuations are +10% (+15%) ...

Megmeet inverters – seven areas of application for high-voltage inverters Megmeet inverters – seven areas of application for high-voltage inverters

1. Metallurgical industry - the application of high-voltage inverter in the metallurgical profession mainly includes plate and wire rod rolling mills, coilers, fans, slurry pumps, etc., with the primary intention of motor energy saving. 2. Electric power industry - China's power generation capacity ranks second in the world, second only to United States. The power profession is also changing.

Megmeet inverter – the basic principle and application of high-voltage inverter Megmeet inverter – the basic principle and application of high-voltage inverter

The basic principle of a high-voltage inverter There are two categories of frequency conversion process of frequency converter: AC-AC form and AC-DC-AC form. Now it is mostly in the form of AC-DC-AC, and the following is a brief introduction to the working principle of this form. Three-phase high-voltage electricity enters the high...

Features of Megmeet CO2/MAG all-digital heavy-duty welder Features of Megmeet CO2/MAG all-digital heavy-duty welder

1. The arc is stable in the field of full current, the spatter is small, and the same welding machine is not only suitable for small current base welding, but also suitable for high current and high deposition rate work 2. Arc concentration and strong penetration. With the same penetration depth, the heat input is reduced by more than 20% compared with other gas shielded welding machines, and the thermal deformation ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top