Megmeet PLC – What are the advantages of PLC compared to relays?

Create Date: 2024-8-30 12:03:23|Source: MEGMEET

(1) In terms of control method: PLC adopts a program to achieve control, which is easy to change or increase the control requirements, and the contact points of PLC are unlimited;

(2) In terms of working mode: PLC adopts serial working mode to improve the anti-interference ability of the system;

(3) Control speed: the contact of the PLC is actually a trigger, and the time of instruction execution is at the microsecond level;

(4) Timing and counting: PLC uses semiconductor integrated circuit as timer, and the clock pulse is provided by crystal oscillator, with high delay accuracy and wide range. The PLC has a counting function that the relay system does not have;

(5) Reliability and maintainability: PLC adopts microelectronic technology, high reliability, and the self-test function can be detected in time.
Megmeet PLC – What are the advantages of PLC compared to relays?

More on that
Megmeet welding machine - resistance welding or laser soldering who is more suitable for electronics industry applications Megmeet welding machine - resistance welding or laser soldering who is more suitable for electronics industry applications

Today's electronics industry revolves around high-speed communication and supercomputing on the Internet, and the requirements for electronic products are getting higher and higher. A large number of micro-precision electronic products are constantly testing the response speed and level of major enterprises in the market. Electronics manufacturers perform real-time, accurate ...

Megmeet PLC - What places should be avoided when installing PLC control? Megmeet PLC - What places should be avoided when installing PLC control?

(1) The ambient temperature exceeds the range of 0-50 °C; (2) The relative humidity exceeds 85% or there is dew condensation (caused by sudden temperature changes or other factors); (3) direct sunlight; (4) There are corrosive and flammable gases, such as hydrogen chloride, ...

Megmeet inverter - common faults and treatment methods of high-voltage inverters Megmeet inverter - common faults and treatment methods of high-voltage inverters

The high-voltage inverter has a highly intelligent computing level and a perfect fault detection circuit, and can provide accurate positioning of all faults, and make clear instructions on the main control interface. In practical application, we find that common faults can be divided into abnormal control channels, IGBT overcurrent, overvoltage...

Megmeet welding machine - failure and maintenance method of DC welding machine Megmeet welding machine - failure and maintenance method of DC welding machine

1. Fault phenomenon: light voltage abnormal indicator Cause: Due to the slow start-up action, the switch contact is not synchronized. Solution: You can turn the device off and on again. 2. Fault phenomenon: the fan does not rotate, and the abnormal voltage indicator light is lit together Causes ...

Megmeet inverter - maintenance precautions and items for high-voltage inverters Megmeet inverter - maintenance precautions and items for high-voltage inverters

Precautions for maintenance of high-voltage inverters 1. Carefully monitor and record the display parameters on the man-machine interface of the inverter, and reflect the abnormality immediately 2. Carefully monitor and record the ambient temperature of the inverter room, and the ambient temperature should be between -5 °C and 40 °C. Phase-shifting transformers ...

Megmeet PLC - the characteristics of the working process of PLC Megmeet PLC - the characteristics of the working process of PLC

1. The PLC adopts the mode of centralized sampling and centralized output, which can reduce the influence of external interference. 2. The working process of PLC is the process of cyclic scanning. The duration of the cyclic scan depends on the speed of execution of the instructions and the length of the user's program. 3. Output to input ...

Common faults and solutions of Megmeet inverter Common faults and solutions of Megmeet inverter

Fault one Fault phenomenon: the leakage protection switch trips, the inverter is energized or the equipment leakage protection switch is operated during operation Solution: 1. When the inverter drives the motor, the leakage value is larger than that of the non-inverter system, and the leakage protection value of the leakage protection switch is required to be more than 150mA, ...

Maintenance inspection of Megmeet inverters Maintenance inspection of Megmeet inverters

1. The Megmeet rectifier module is damaged It is usually caused by grid voltage or internal short circuit. In the case of sweeping the internal short circuit, the rectifier bridge is replaced. When dealing with faults on site, we should focus on checking the status of the user's power grid. Such as the power grid voltage, whether there is an electric welding machine, etc.

Megmeet welding machines – the main application area of resistance welding Megmeet welding machines – the main application area of resistance welding

(1) Spot welding: The weldment is pressed between the two cylindrical electrodes, heated by electricity, so that the weldment melts at the contact to form a nugget, and then the power is cut off, and it solidifies and crystallizes under pressure to form a dense solder joint. Spot welding is suitable for welding thin plates (laps) and steel bars below 4 mm.

Megmeet inverters – Routine maintenance of high-voltage inverters requires precautions Megmeet inverters – Routine maintenance of high-voltage inverters requires precautions

1. The operating ambient temperature of the inverter (mainly refers to the air temperature of the air inlet of the power unit cabinet) requires a minimum ambient temperature of -5 °C and a maximum ambient temperature of 40 °C. In order to improve the reliability and extend the service life of the drive, check the following items: Air conditioning and refrigeration ...

Megmeet inverter – three ways to connect the PLC to the inverter Megmeet inverter – three ways to connect the PLC to the inverter

(1) Use the analog output module of PLC to control the analog output module of the inverter The analog output module of the PLC outputs 0-5V voltage signal or 4-20mA current signal, which is used as the analog input signal of the inverter to control the output frequency of the inverter. This control method is simple to wiring, but it needs to be selected and changed.

Megmeet PLC – How does PLC communicate with computers? Megmeet PLC – How does PLC communicate with computers?

1. In this computer, right-click, manage, check to find the device manager, plug in the USB-PPI cable (one end is connected to the computer, the other end is connected to the PLC), the computer device manager will pop up the port USB-SERLAL CH304 (com3), the number in parentheses may change, indicating that you have found the cable. This...

Megmeet inverters – what are the development directions of inverter-related technologies? Megmeet inverters – what are the development directions of inverter-related technologies?

1. Intelligent network The intelligent inverter does not need to set a lot of parameters when it is used, and it has the function of fault self-diagnosis, which has high stability, high reliability and practicability. The Internet can be used to realize the linkage of multiple inverters, and even the inverter complex in the factory.

Various welding methods for Megmeet welding machines Various welding methods for Megmeet welding machines

1) Hand arc welding (STICK) Shielded Arc Welding (abbreviated SMAW) in English, The principle is: the arc occurs between the coating electrode and the base metal, and the welding method of arc thermal ablation electrode and base metal is used. The outer layer of the electrode is covered with solder, which is dissipated in case of heat.

Megmeet PLC – the three basic process contents of PLC work Megmeet PLC – the three basic process contents of PLC work

1. Input processing Input processing is also called input sampling. In this phase, the through-end state of all input terminals is read sequentially, and the read information is stored in the corresponding image register in memory. Here the input image register is flushed. Then the program execution phase begins. In the execution of the procedure ...

Welding methods for Megmeet hand arc welding and MIG/MAG welding Welding methods for Megmeet hand arc welding and MIG/MAG welding

1) Hand arc welding (STICK) Shielded Arc Welding (abbreviated SMAW) in English, The principle is: the welding method of generating an electric arc between the coating electrode and the base metal, and using the arc heat to melt the electrode and the base metal. The outer layer of the electrode is covered with solder, and it melts when heated.

Megmeet PLC maintenance inspection Megmeet PLC maintenance inspection

PLC maintenance and inspection steps: 1. Check and make sure the mains power is on (120 VAC) 2. Check the available 24V power supply 3. Identify problem areas. It is recommended that peak currents cover this error code, a control method consisting of multiple components distributed over an area or process.

Megmeet PLC – 10 PLCs integrated failure analysis Megmeet PLC – 10 PLCs integrated failure analysis

1. Grounding problems The grounding requirements of the PLC system are relatively strict, and it is best to have an independent dedicated grounding system, and it should also be noted that other equipment related to PLC should also be reliably grounded. When multiple circuit grounding points are connected together, unexpected currents can be generated, resulting in logic errors or ...

Megmeet inverter - heat dissipation design considerations for high-power high-voltage inverters Megmeet inverter - heat dissipation design considerations for high-power high-voltage inverters

(1) Select components and materials with good heat resistance and thermal stability to increase their allowable working temperature; (2) Reduce the heat generated inside the equipment (device). To this end, micropower devices, such as low-loss IGBTs, should be used more often, and the number of heat-generating components should be minimized in the circuit design.

Megmeet inverter - the selection principle and precautions of the inverter Megmeet inverter - the selection principle and precautions of the inverter

1. Select the inverter according to the load characteristics A: Fans and pumps are the most common loads: the requirements for the inverter are the simplest, as long as the inverter capacity is equal to the capacity of the motor (air compressors, deep water pumps, sediment pumps, and fast-changing music fountains need to increase their capacity). ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top