Megmeet PLC - What is the difference between PLC and servo control system

Create Date: 2024-8-30 12:03:23|Source: MEGMEET

1. The meaning of the representation is different:

PLC is the abbreviation of planar optical waveguide (technology), the so-called planar optical waveguide, means that the optical waveguide is located in a plane.

Servo control system is used to accurately follow or reproduce a certain process of feedback control system, in many cases, servo system refers to the controlled quantity (output of the system) is mechanical displacement or displacement velocity, acceleration of the feedback control system.

2. Different functions:

PLC is a technology, it does not refer to a certain type of product, nor is it a splitter, the most common PLC splitter is made of silicon dioxide (SiO2). The materials involved in PLC technology include: glass/silica, lithium niobate (LiNbO3), III-V semiconductor compounds (such as InP, GaAs, etc.), silicon on insulators, silicon nitride oxide (SiON), polymer (Polymer), etc.

The servo control system is to make the output mechanical displacement (or rotation angle) accurately track the input displacement (or rotation angle). The structural composition of the servo system is not in principle different from other forms of feedback control systems.
Megmeet PLC - What is the difference between PLC and servo control system

More on that
Megmeet inverter - the basic method and steps of inverter commissioning Megmeet inverter - the basic method and steps of inverter commissioning

1. No-load energizing test of inverter 1. Ground the grounding terminal of the inverter. 2. Connect the power input terminal of the inverter to the power supply through the leakage maintenance switch. 3. Check whether the factory display of the inverter window is normal, if it is incorrect, it should be reset, otherwise it should be ...

Megmeet PLC - common causes and treatment methods of PLC failures Megmeet PLC - common causes and treatment methods of PLC failures

Peripheral circuit component failure This type of failure often occurs in the failure of the PLC after a certain period of work. In the PLC control loop, if there is a component damage fault, the PLC control system will immediately and automatically stop working. The input circuit is PLC to accept switching quantities, analog quantities, etc.

Megmeet inverters – what do you need to pay attention to when choosing the power of the inverter? Megmeet inverters – what do you need to pay attention to when choosing the power of the inverter?

The system efficiency is equal to the product of the efficiency of the inverter and the efficiency of the motor, and the system efficiency is higher only when both are working at higher efficiency. From the perspective of efficiency, the following points should be paid attention to when selecting the power of the inverter: 1) Inverter power value and motor power ...

Megmeet inverter - common faults and treatment methods of high-voltage inverters Megmeet inverter - common faults and treatment methods of high-voltage inverters

1. Control through this abnormal failure The abnormal fault of the control channel is usually caused by the optical fiber communication between the sub-PWM board and the power unit board, which is generally caused by the following situations: 1. Poor contact of the optical fiber connection part or falling off of the optical fiber head; 2. Optical fiber signal transmitter/receiver ...

Megmeet PLC - the difference between PLC and frequency converter Megmeet PLC - the difference between PLC and frequency converter

1. The role is different A PLC (Programmable Logic Controller) is an electronic system designed for digital operations in an industrial environment. The inverter is the application of frequency conversion technology and microelectronics technology to control the AC motor by changing the frequency of the motor working power supply.

Megmeet inverter mv600 alarm code ENOC2 Megmeet inverter mv600 alarm code ENOC2

1. If there is a sharp acceleration or deceleration, please extend the acceleration and deceleration time. 2. Avoid rapid increase in load. 3. Check whether there is a short circuit in the UVW of the motor terminal. 4. The module is damaged, and the drive circuit is damaged, resulting in an overcurrent alarm. ...

The unified setting of the Megmeet welding machine and the parameter setting of the system The unified setting of the Megmeet welding machine and the parameter setting of the system

1. Unified setting of Megmeet welding machine The so-called unification of welding means that the welding machine automatically matches the welding voltage according to the currently set welding current and the unification voltage correction value. The unification setting of Megmeet welder should first turn on the function on the welder side, ...

Megmeet Inverter - Precautions for the Use of Inverter (1-10) Megmeet Inverter - Precautions for the Use of Inverter (1-10)

1. The inverter must be selected correctly. 2. Read the product manual carefully, and wiring, installation and use in accordance with the requirements of the manual. 3. The inverter device should be reliably grounded, and the radio frequency interference should be suppressed to prevent the inverter from causing electric shock due to leakage. 4、 ...

Failure and maintenance of welding machines Failure and maintenance of welding machines

1. Damage to the welding power supply. Due to the high current and high voltage during welding, when the welding current exceeds 20% of the rated value, overcurrent protection will appear, so that the circuit will automatically cut off the power supply. In addition, if the welding time is too long, it can also cause overcurrent. Therefore, we should try our best to ...

Megmeet PLC maintenance and processing methods Megmeet PLC maintenance and processing methods

1. CPU abnormality: When the CPU is abnormally alarmed, check the device connected to the internal line of the CPU unit. The specific method is to replace the units that may cause failures in turn, find out the faulty units, and deal with them accordingly. 2. Memory abnormality: When the memory is abnormal alarm, if it is a program ...

Megmeet inverter - common faults and treatment methods of high-voltage inverters Megmeet inverter - common faults and treatment methods of high-voltage inverters

The high-voltage inverter has a highly intelligent computing level and a perfect fault detection circuit, and can provide accurate positioning of all faults, and make clear instructions on the main control interface. In practical application, we find that common faults can be divided into abnormal control channels, IGBT overcurrent, overvoltage...

Common faults of Megmeet drives and how to deal with them Common faults of Megmeet drives and how to deal with them

1. When the oscilloscope looks at the current monitoring output of the driver, it finds that it is all noisy and cannot be read Cause: The current monitoring output is not blocked from the AC power supply (transformer). Solution: You can use a DC voltmeter to detect and investigate. 2. Servo motor high speed ...

Megmeet PLC - the connection method between the PLC and the server Megmeet PLC - the connection method between the PLC and the server

The first is that the PLC sends a start/stop signal to the server through the I/O point, and the server controls the operation of the servo motor. The PLC controls the operation/stop of the servo through the digital output, so as to achieve the purpose of controlling the servo motor. The second is through the pulse output of the PLC, which ...

The principle and characteristics of Megmeet tungsten argon arc welding and resistance welding The principle and characteristics of Megmeet tungsten argon arc welding and resistance welding

3) Tungsten argon arc welding (TIG) Non-melting electrode gas arc welding, TIG welding, English is Tungsten Inert Gas (abbreviated TIG), also known as Gas Tungsten Arc Welding (abbreviated GTAW) The principle is: TIG welding is in argon and other inert gases.

Common faults and solutions of Megmeet inverter Common faults and solutions of Megmeet inverter

Fault one Fault phenomenon: the leakage protection switch trips, the inverter is energized or the equipment leakage protection switch is operated during operation Solution: 1. When the inverter drives the motor, the leakage value is larger than that of the non-inverter system, and the leakage protection value of the leakage protection switch is required to be more than 150mA, ...

Megmeet inverter – the inverter's protection of itself, the motor and the system Megmeet inverter – the inverter's protection of itself, the motor and the system

1. The inverter protects itself Instantaneous overcurrent, overvoltage, undervoltage, overload, short circuit to ground, abnormal control circuit, then for the protection of the inverter itself, the limit value of overcurrent, overvoltage, undervoltage, etc., when the inverter is running, if it exceeds ...

Megmeet PLC - how the PLC communicates with the host computer Megmeet PLC - how the PLC communicates with the host computer

The PLC communicates with the host computer, and BlandC is used to write the communication program between the host and the PLC, and the COM1 port must be initialized, the baud rate is 9600bps, and the parity check bit adopts even check, and the seven-digit valid data is used. When the computer receives the response character ACK from the PLC, it ...

Megmeet inverter - a common measure for anti-interference of high-voltage inverters Megmeet inverter - a common measure for anti-interference of high-voltage inverters

(1) The E end of the high-voltage inverter should be connected to the shell of the control cabinet and the motor, and should be connected to the ground, and the grounding resistance should be less than 100Ω, which can absorb surge interference. (2) The input or output of the high-voltage inverter is equipped with an inductive magnetic ring filter. Flat and 3-4 turns, helps to inhibit ...

Welding methods for Megmeet hand arc welding and MIG/MAG welding Welding methods for Megmeet hand arc welding and MIG/MAG welding

1) Hand arc welding (STICK) Shielded Arc Welding (abbreviated SMAW) in English, The principle is: the welding method of generating an electric arc between the coating electrode and the base metal, and using the arc heat to melt the electrode and the base metal. The outer layer of the electrode is covered with solder, and it melts when heated.

Megmeet inverter – failure analysis of air compressor inverter Megmeet inverter – failure analysis of air compressor inverter

1. The voltage is unstable In the process of using the inverter air compressor, sometimes the voltage is unstable. If the voltage is unstable, a load may occur, causing the compressor to not start properly. Solution: The regulator can be adjusted in time. 2. The main ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top