Common faults and solutions of Megmeet inverter
Fault one
Fault phenomenon: the leakage protection switch trips, the inverter is energized or the equipment leakage protection switch is operated during operation
Solution: 1. When the inverter drives the motor, the leakage value is larger than that of the non-inverter system, and the leakage protection value of the leakage protection switch is required to be more than 150mA, ...
|
|
New Arrivals! Hollysys' two blockbuster products were unveiled at the Zhongguancun Forum Technology Trading Conference
On September 24, the 2021 Zhongguancun Forum, co-sponsored by the Ministry of Science and Technology of China, the Chinese Academy of Sciences, the China Association for Science and Technology, and the Beijing Municipal People's Government, officially opened in Beijing. As one of the main agendas of the forum, the Zhongguancun International Technology Exchange Conference closely follows the "smart· healthy· carbon neutrality...
|
|
Introduction to Megmeet welding machine
The EhaveCM350AR is a fully digital inverter melting multi-functional industrial heavy-duty Megmeet welding machine launched by Megmeet for global metalworking manufacturing. It brings customers higher quality and higher efficiency welding experience and value with excellent arc characteristics, reliability and high efficiency, and helps customers ...
|
|
Megmeet drives – routine and regular maintenance of drives
1. Maintenance items and scope:
Daily maintenance and maintenance of inverter
Due to the influence of environmental temperature, humidity, dust and vibration, it will lead to the aging of the internal components of the inverter, resulting in the potential failure of the inverter or reducing the service life of the inverter. Therefore, there is a must ...
|
|
Megmeet PLC – the maintenance steps of the PLC control cabinet
1. Data backup
When carrying out maintenance, we must cut off the power, data backup between power outages is an important link, for the data that needs to be archived for a long time, you can back up the historical trend data to the mobile hard disk, and then turn off the Windows-based operating system (Note...
|
|
Megmeet drives – safety precautions for the installation of drives
When the inverter is installed and wired;
Note: When more than two inverters are installed in the same cabinet, please pay attention to the installation position and spacing to ensure the heat dissipation effect.
Dangerous:
1. It should be operated by professional electrical engineering personnel, otherwise there is a risk of electric shock.
2. Please make sure before wiring...
|
|
Megmeet PLC – the three basic process contents of PLC work
1. Input processing
Input processing is also called input sampling. In this phase, the through-end state of all input terminals is read sequentially, and the read information is stored in the corresponding image register in memory. Here the input image register is flushed. Then the program execution phase begins. In the execution of the procedure ...
|
|
The cause and treatment method of the fault code Eroc1 of Megmeet inverter
1. Overcurrent fault of inverter
Fault Code: OCF.
(1) Fault name: inverter overcurrent fault
(2) The cause of the failure: the motor nameplate data input is incorrect: the load dragged by the motor is too heavy: the machinery is stuck; Motor stalled.
(3) ...
|
|
Megmeet PLC - What are the steps to complete PLC commissioning?
1. Check the circuit according to the drawing (without power transmission)
The drawings of the general PLC system include two parts: the drawings in the cabinet and the drawings outside the cabinet; The drawing in the cabinet refers to the wiring diagram inside the cabinet; The out-of-cabinet drawings are the wiring diagrams of all electrical cabinets.
This part needs to be checked for;
...
|
|
Megmeet drives – how should high-voltage drives be maintained after they are shut down?
1. Check the surrounding situation - carefully check the ventilation and lighting of the inverter and the surrounding environment. It is necessary to ensure that the ventilation equipment is functioning properly and that the lighting equipment is in working order.
2. Check the internal cable - open the inverter cabinet door and check whether the internal cable is damaged, the cable ...
|
|
Megmeet inverter - common faults and treatment methods of high-voltage inverters
The high-voltage inverter has a highly intelligent computing level and a perfect fault detection circuit, and can provide accurate positioning of all faults, and make clear instructions on the main control interface. In practical application, we find that common faults can be divided into abnormal control channels, IGBT overcurrent, overvoltage...
|
|
Megmeet inverter - what are the control methods of the inverter?
Sinusoidal Pulse Width Modulation (SPWM) control mode
It is characterized by simple structure of control circuit, low cost, good hardness of mechanical characteristics, and can meet the smooth speed regulation requirements of general transmission, and has been widely used in various fields of industry. However, this type of control is at low frequencies, ...
|
|
Megmeet drives – the replacement steps for high-voltage drive power units
1) Shut down, so that the inverter out of the operating state;
2) Cut off the high-voltage power supply and push out the high-voltage cabinet trolley (when there is a bypass cabinet. The inverter can be isolated by the disconnecting switch of the bypass cabinet), the local or remote high-voltage disconnect switch can be locked, and the high-voltage cabinet grounding switch can be grounded;
3) Hit ...
|
|
Megmeet PLC - What are the main components of PLC control cabinet?
1. Air switch
Air switch is also called air circuit breaker, referred to as air open, is an indispensable component of the control cabinet, usually from the outside into the cabinet of power supply, must go through the air open, in order to reach the inside, the function of air open in addition to the power supply, more as short circuit protection and overload protection...
|
|
Megmeet inverter - precautions for inverters at high temperatures
1. Carefully monitor and record the display parameters on the man-machine interface of the inverter, and reflect the abnormality immediately;
2. Carefully monitor and record the ambient temperature of the frequency conversion room, and the ambient temperature should be between -5 °C and 40 °C. The temperature rise of the phase-shifting transformer should not exceed 130°C;
3. Summer ...
|
|
Megmeet inverter – the energy-saving principle of low-voltage inverter
Inverter energy saving
The energy saving of the inverter is mainly manifested in the application of fans and pumps. In order to ensure the reliability of production, all kinds of production machinery are designed with power drive, and there is a certain amount of surplus. When the motor cannot operate at full load, in addition to meeting the power drive requirements, ...
|
|
Common faults and solutions of Megmeet inverter
1. Leakage protection switch
Phenomenon: The leakage protection switch of the equipment is activated when the inverter is powered on or running
Measures:
When the inverter drives the motor, the leakage value is larger than that of the non-inverter system, and the leakage protection value of the leakage protection switch is required to be 150mA and above, and the action delay is ...
|
|
Solutions to common faults of Megmeet inverter (2)
Fault three
Fault phenomenon: There is a rebound phenomenon when the rotation starts
Solution: 1. Set the start frequency P08.02 and start frequency time P08.03 appropriately (such as P08.02=P08.03=0.5)
2. Appropriately reduce the stator resistance (P03.07) and no-load current value (P03.11 ...
|
|
The application of Megmitte industrial control products in high-speed precision CNC machine tools
With the rapid development of the machinery manufacturing industry, the traditional general machine tool can no longer meet the changing parts processing needs of the shopping mall. CNC machine tools have undeniably become the mainstream processing equipment of today's machinery manufacturing. In response to the special application needs of the machine tool industry, Megmeet has launched the MV series of high-function ...
|
|
Megmeet PLC - the difference between PLC and frequency converter
1. The role is different
A PLC (Programmable Logic Controller) is an electronic system designed for digital operations in an industrial environment.
The inverter is the application of frequency conversion technology and microelectronics technology to control the AC motor by changing the frequency of the motor working power supply.
|