Adjustment method of the Sick WFS3-40N415 sensor

Create Date: 2024-8-30 12:03:23|Source: SICK/Sick

(1) Automatic calibration: When the workpiece enters the sensitive area of the probe, press and hold the "SET" button for 3 seconds, and the sensitivity value will be set and displayed in green.

(2) Two-point calibration: When the workpiece does not enter the sensitive area, press and hold the "SET" button for three seconds, one sensitive value is memorized, then place the workpiece in the sensitive area, press the "SET" key to hold for three seconds, another sensitive value is remembered, when the sensitive value changes from one value to another, the sensor produces a level change.

(3) General calibration: You can also increase or decrease the sensitivity setting value by pressing the "Select Button" and the left and right buttons.

(4) Position calibration: When the workpiece does not enter the sensitive area, hold the "SET" button for three seconds, then place the workpiece at a certain distance from the probe, press the "SET" button to hold for three seconds, a sensitive value is memorized, and every time the workpiece reaches this position, the sensor produces a level change.
Adjustment method of the Sick WFS3-40N415 sensor

More on that
Sick TMx22 tilt sensor – smaller, smarter Sick TMx22 tilt sensor – smaller, smarter

The miniaturization, integration, and intelligence of sensors are the main trends of industrial development, and the increasing demand for small and integrated smart chips in industrial scenarios also provides better means for equipment integration and intelligence. Sick is also deeply aware of the small size of the large ...

How to maintain the Sick sensor How to maintain the Sick sensor

1. It is necessary to prevent the sensor from contacting corrosive gases, so as not to cause corrosion and affect the measurement results. 2. If the measurement is a high-temperature medium, the SICK sensor should see whether the temperature is within the suitable temperature range of the sensor.

How to debug and use Sick fiber optic sensors How to debug and use Sick fiber optic sensors

1. Basic composition The appearance of this series of fiber optic sensors is basically composed of the following parts, from left to right: (1) SET button, this button can be used for sensitivity setting. The basic principle of this sensor is: through the induction of the refractive index of different media by the fiber optic probe, ...

Sick Sensors – Applications for thermistor sensors Sick Sensors – Applications for thermistor sensors

1. Thermistor sensor temperature measurement Thermistor sensors used to measure temperature are generally simple in structure and inexpensive. Thermistors without an outer protective layer can only be used in dry places; Hermetically sealed thermistors are not afraid of moisture erosion and can be used in harsh rings.

Sick Sensors – An introduction to the classification of proximity sensors Sick Sensors – An introduction to the classification of proximity sensors

Proximity sensors are divided according to their working principle: High-frequency oscillation type, capacitive type, induction bridge type, permanent magnet type, Hall effect type, etc. According to the principle of operation, it can be divided into three categories: High-frequency oscillation type using electromagnetic induction, magnetic force type using magnets, and ...

Sick Sensors – Installation Requirements for RTD Sensors Sick Sensors – Installation Requirements for RTD Sensors

1. In order to have sufficient heat exchange between the measuring end of the RTD and the medium to be measured, the location of the measuring point should be reasonably selected, and the installation of RTD near the valve, elbow, pipe and equipment should be avoided as much as possible. 2. The thermal resistance with a protective sleeve has heat transfer and heat dissipation loss, in order to reduce the ...

Sick Sensors – Precautions for the use of grating displacement sensors Sick Sensors – Precautions for the use of grating displacement sensors

1. Add a protective cover as much as possible, and clean up the chips and oil splashed on the ruler in time to strictly prevent any foreign matter from entering the inside of the grating ruler sensor housing. 2. When plugging and unplugging the grating displacement sensor and the plug holder of the digital display, the power should be turned off. 3. For the extension of the dust seal ...

There are several undesirable fault phenomena that are common with SICK sensors There are several undesirable fault phenomena that are common with SICK sensors

The color and number of SICK sensor wires are conveniently different. Some are six-wire sensors. However, the two sense lines are also connected to the sensor's book input signals E+ and E-, and we can ignore these two feedback lines or combine them into one. The color of each cable ...

Adjustment method of sensing distance of Sick photoelectric sensor Adjustment method of sensing distance of Sick photoelectric sensor

1. Find the screw at the end of the switch, twist it clockwise to adjust it far, and twist it counterclockwise to adjust it closer. 2. It can increase the intensity of the light source. 3. Improve the sensitivity of the switch sensor. 4. It can also be adjusted according to the instructions for use. ...

Sick Sensors – An introduction to the photoelectric effect of photoelectric sensors Sick Sensors – An introduction to the photoelectric effect of photoelectric sensors

It is a physical phenomenon in which light irradiates certain substances and changes the conductive properties of the substance, which can be divided into three categories: external photoelectric effect, internal photoelectric effect and photogenerated volt effect. The external photoelectric effect refers to the physical emission of electrons from the surface of an object under the action of light.

SICK brought new products to the Industry Fair SICK brought new products to the Industry Fair

The 17th China International Industry Fair (IAS2015) was held in the National Convention and Exhibition Center (Shanghai) from November 3 to 7, 2015.

Sick Sensors – Troubleshooting Methods for Photoelectric Sensors Sick Sensors – Troubleshooting Methods for Photoelectric Sensors

1. The pressure goes up, the output of the transmitter does not go up to this situation, you should first check whether the pressure interface is leaking or blocked, if you admit that it is not, check the wiring method and check the power supply, if the power supply is normal, then simply pressurize to see if the output changes, maybe observe whether the zero position of the sensor has an output, if there is no ...

Sick Sensors – How to use the Contrast Sensor Sick Sensors – How to use the Contrast Sensor

1. There are 4 wires for the wiring sensor, among them, the red or brown wire is connected to the positive power supply, and the black wire is connected to the negative power supply; The green or blue wire is the dark output line, and the white or yellow wire is the bright output line, the user can choose one of them according to his needs, and the other is not used, but it should be insulated. Lines are not allowed ...

Sick Sensors – Infrared Sensor Installation Requirements and Precautions Sick Sensors – Infrared Sensor Installation Requirements and Precautions

Infrared sensor installation requirements: 1. Infrared sensors are usually set up in areas where intruders may enter or where high-value items are stored, such as the living room, master bedroom, corridor or corridor of a general family; In general, companies usually set up sensors in computer rooms, corridors, warehouses, etc.

An introduction to the three common types of photoelectric sensors An introduction to the three common types of photoelectric sensors

1. Photoelectric switch sensor The occlusion between the transmitter and receiver is used to detect states such as motion, object presence, or object position. When the measured object passes through the occlusion beam, the intensity of the light signal received by the receiving head changes, which in turn triggers the switching signal. Photoelectric switch ...

Sick sensors – the three major functions of photoelectric sensors Sick sensors – the three major functions of photoelectric sensors

First, the transmission effect Through the photoelectric sensor, it can be very good to complete the transfer between the media, which is a very popular way of action in many industrial fields and enterprises, because some energy can not be transmitted manually and can only be reached by machines.

Parameter settings for the Sigg distance sensor Parameter settings for the Sigg distance sensor

1. Set to "Surface" to measure the distance from the first surface within the sensor's detection range. This setting is available for all sensor heads. 2. Set to Glass Thickness to measure the distance from the front to the back of a transparent object, such as glass. This means that it has been measured with the sensing ...

Sick Sensors - Introduction to the static and dynamic characteristics of displacement sensors Sick Sensors - Introduction to the static and dynamic characteristics of displacement sensors

Dynamic features: The so-called dynamic characteristics of the sensor refer to the characteristics of the output of the sensor when the input changes. In practice, the dynamic characteristics of a sensor are often expressed in terms of its response to some standard input signal. This is because the sensor's response to a standard input signal ...

Sick sensors – the working methods and characteristics of fork photoelectric sensors and their differences Sick sensors – the working methods and characteristics of fork photoelectric sensors and their differences

How fork photoelectric sensors work: Placing an optical transmitter and a receiver facing each other on either side of a slot is a fork photoelectric. The luminaire emits infrared or visible light, and the light receiver receives the light in an unobstructed condition. But when the detected object passes through the trough ...

What are the advantages of Sick sensors – laser distance sensors? What are the advantages of Sick sensors – laser distance sensors?

1. Laser ranging sensor 2. Measuring distance range 0.5-300 meters, 3000 meters (to use reflector) 3. The accuracy error of the whole process is 20 mm 4. The continuous service life of the laser is more than 50,000 hours (5 years) 5. Standard RS232, RS422 ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top