Infrared sensor installation requirements:
1. Infrared sensors are usually set up in areas where intruders may enter or where high-value items are stored, such as the living room, master bedroom, corridor or corridor of a general family; However, most companies usually set up sensors in computer rooms, aisles, warehouses and storage areas. Therefore, before installing the wiring and control surface tray of the sensor, it is necessary to familiarize yourself with the layout of the system to determine the optimal installation location of the sensor.
2. The installation height of the sensor is not arbitrary, which will directly affect the sensitivity of the infrared sensor and the effect of anti-small animals, and the installation height of the wall-mounted infrared sensor is generally 2.0-2.2 meters.
3. It is not suitable to face glass doors and windows, there will be two problems with glass doors and windows: one is white light interference, although the passive infrared sensor (PIR) has a strong suppression function for white light, but after all, it is not 100% suppression, do not face glass doors and windows, you can avoid the interference of strong light; The second is to avoid complex environmental interference outside doors and windows, such as direct sunlight, crowds, mobile vehicles, etc.
4. It is not advisable to face large objects that are easy to swing, because large objects can instantly cause sudden airflow changes in the detection area, which may also cause false alarms; For example, outdoor sensors should avoid large trees and tall shrubs.
5. It is not advisable to face the hot and cold vents or cold and heat sources, the passive infrared sensor induction effect is closely related to the change of temperature, the cold and hot vents and the cold and heat sources may cause false alarms of the sensor, and sometimes the air convection through doors and windows will also cause false alarms for some low-performance sensors.
6. The infrared probe can only be installed indoors, and its false alarm rate has a great relationship with the installation location, and the correct installation position should be 2.0-2.2 meters from the ground; Keep away from air conditioners, refrigerators, stoves, and other places where air temperature changes are sensitive.
7. The infrared probe should be installed in the corner of the room as far as possible to obtain the most ideal detection range, and there should be no partitions, furniture, large bonsai or other isolation objects within the detection range.
8. There should be no partitions, furniture, large bonsai or other isolators within the detection range as far as possible; It is best not to install two wireless infrared sensors in the same space to avoid interference due to simultaneous triggering; The infrared sensor should be at an angle to the walking line in the room, and the sensor is the least sensitive to radial movement and the most sensitive to tangential (i.e., perpendicular to the radius) movement. Choosing the right installation location in the field is an extremely important part of avoiding false alarms and achieving the best detection sensitivity of the infrared sensor.
Precautions for the use of infrared sensors:
1. According to the minimum and maximum temperatures and their durations on the prevention site, select the active infrared intrusion sensor with the appropriate working temperature; If the ambient temperature is too low, a special heater can be used to ensure the normal operation of the sensor.
2. The active infrared intrusion sensor is seriously affected by fog, and equipment with automatic gain function should be selected for outdoor use (the sensitivity of such equipment will be automatically adjusted when the climate changes); In addition, the detection distance of the selected equipment has a margin of more than 20% from the actual warning distance to reduce the false alarm of the system caused by climate change.
3. When using outdoors, be sure to choose a dual-beam or a 3-beam active infrared intrusion sensor to reduce the false alarm of the system caused by birds, fallen leaves, etc.
4. The wavelengths of the infrared light-emitting diodes used in the active infrared sensor are around 0.85 μm and 0.95 μm, respectively. The former has red exposure, and its concealment is not as good as the latter.
5. Active infrared intrusion detectors should not be used outdoors in foggy areas and areas with dirty and windy sand.
6. When using active infrared intrusion sensors in open areas or on fences and roofs, equipment with lightning protection functions should be selected.
7. When there is a broken wall and the distance is close, reflective devices can be selected to reduce the number of infrared sensors.
Infrared sensors are commonly used for non-contact temperature measurement, gas composition analysis, and non-destructive testing, and are widely used in medical, military, space technology, and environmental engineering. For example, the thermal image of the surface temperature of the human body can be measured remotely by infrared sensors, which can find the location of abnormal temperature and diagnose and treat diseases in time (see thermal imaging camera); The use of infrared sensors on artificial satellites to monitor the earth's clouds can achieve large-scale weather forecasting; Infrared sensors are used to detect overheating of engines running on aircraft, etc.
|
More on that
|
The GLS621, a new member of the Sick AGV/AGC navigation sensor family
As a special sensor for the two-dimensional code positioning and navigation market, GLS621 is mainly used in warehousing AGVs or warehouse handling robots based on the principle of inertial two-dimensional code navigation.
|
|
Sick Sensors – An introduction to the photoelectric effect of photoelectric sensors
It is a physical phenomenon in which light irradiates certain substances and changes the conductive properties of the substance, which can be divided into three categories: external photoelectric effect, internal photoelectric effect and photogenerated volt effect. The external photoelectric effect refers to the physical emission of electrons from the surface of an object under the action of light.
|
|
How to maintain the Sick sensor
1. It is necessary to prevent the sensor from contacting corrosive gases, so as not to cause corrosion and affect the measurement results.
2. If the measurement is a high-temperature medium, the SICK sensor should see whether the temperature is within the suitable temperature range of the sensor.
|
|
Adjustment method of sensing distance of Sick photoelectric sensor
1. Find the screw at the end of the switch, twist it clockwise to adjust it far, and twist it counterclockwise to adjust it closer.
2. It can increase the intensity of the light source.
3. Improve the sensitivity of the switch sensor.
4. It can also be adjusted according to the instructions for use.
...
|
|
Introduction to the characteristics of Sick sensors
Static characteristics of Sick sensors
The static characteristics of the Sick sensor refer to the correlation between the output and the input of the Sick sensor for the static input signal. Since the input and output are not time-dependent, the relationship between them, i.e. the static ...
|
|
Classification and introduction of SICK sensors - pressure sensors
Pressure Sensor Classification:
There are great differences in the skills, design, function and adaptability of pressure sensors, as well as the conditions and price of pressure sensors. According to preliminary estimates, there are more than 60 types of pressure sensors in the world and at least 300 companies produce pressure sensors.
Pressure...
|
|
What are the relevant applications for Sick sensors – ultrasonic sensors?
Main applications:
Ultrasonic sensing technology is used in different aspects of production practice, and medical application is one of its most important applications. The application of ultrasound in medicine is mainly to diagnose diseases, and it has become a clinical...
|
|
Sick 3D machine vision enables intelligent guidance for tire laser lettering
With the continuous promotion of the dual carbon policy, a sustainable production and operation model is particularly important for manufacturing enterprises. The tire and rubber industry is also seeking a greener way of development.
With the iterative improvement of the production process, the tire and rubber enterprises will also ...
|
|
Sick Sensors – Advantages of load cells
Resistance, inductance and capacitance are the three major types of passive components in electronic technology, and a capacitive sensor is a sensor that converts the measured change into a capacitance change, which is essentially a capacitor with variable parameters.
Capacitive sensors offer the following advantages:
(1) ...
|
|
Sick Sensors – Common classifications and connections for RTD sensors
1. Platinum thermal resistance
The platinum metal is used as the temperature sensing element, and then together with the inner lead and the protective tube, the platinum thermal resistance temperature sensor is formed. It is also often connected to external measurement circuits, controls, and mechanisms to form a temperature sensor.
This sensor has two main ...
|
|
What are the features of Sick Sensors – Proximity Sensors?
(1) Since the inspection can be carried out in a non-contact manner, it does not wear or damage the object to be inspected.
(2) Since the contactless output method is adopted, the life extension (except for the magnetic type) is made of semiconductors, and the life of the docking point is not affected.
(3) It is not the same as the light detection method.
|
|
Introduction to the advantages and disadvantages of Sick sensors
1. Advantages
(1) Germany SICK flow sensor can be used to measure industrial conductive liquids or slurries.
(2) No pressure loss.
(3) The measuring range is large, and the diameter of the electromagnetic flow transmitter is from 2.5mm to 2.6m.
(4) Germany Sick SICK traffic transmission ...
|
|
Sick Sensor – The difference between an infrared sensor and a laser sensor
Infrared sensors: Sensors that take advantage of the physical properties of infrared rays to make measurements. Infrared light is also known as infrared light. The infrared sensor does not have direct contact with the measured object during measurement, and the anti-interference performance is poor, so the lens needs to filter the infrared light before measurement, and it needs to be calibrated regularly.
...
|
|
Sick Sensors - How to test the quality of load cells?
The load cell is a relatively easy to damage component in the weighing cell, and it is easy to cause damage to the sensor due to impact, overload, aging, high temperature, corrosion, etc.
(1) Physical observation: observe whether the appearance of the load cell is deformed, cracked, etc.
(2) Measure the resistance ...
|
|
An introduction to the three common types of photoelectric sensors
1. Photoelectric switch sensor
The occlusion between the transmitter and receiver is used to detect states such as motion, object presence, or object position. When the measured object passes through the occlusion beam, the intensity of the light signal received by the receiving head changes, which in turn triggers the switching signal. Photoelectric switch ...
|
|
Sick boutique makes a comeback: capacitive proximity sensors
Are you still having a headache about detecting the presence or absence of objects?
Are you still bothered by checking the liquid level?
Are you still troubled by the limited installation of application scenarios?
Today, SICK is back with the secret weapon of substance detection: capacitive proximity sensors.
This capacitive sensing ...
|
|
Sick Sensors – How to use the Contrast Sensor
1. There are 4 wires for the wiring sensor, among them, the red or brown wire is connected to the positive power supply, and the black wire is connected to the negative power supply; The green or blue wire is the dark output line, and the white or yellow wire is the bright output line, the user can choose one of them according to his needs, and the other is not used, but it should be insulated. Lines are not allowed ...
|
|
Sick Sensors – the working principle and application of color sensors
What are the applications of color sensors?
1. Discrete photodiode with color filter
The traditional color sensing method uses a structure in which three to four photodiodes are combined on a single chip, and red, green, and blue filters are placed on the surface of the photodiodes. An independent ...
|
|
Detailed explanation of fault judgment and maintenance of SICK sensors
Analysis of the factors that may cause the zero point change of the SICK sensor: overload will lead to a sudden change in the zero point, and the output resistance will obviously exceed the specified value impact, as above; Moisture return or turbidity, so it is mainly manifested as a continuous change of 0 point, high and low, etc., at this time, the ground resistance will be further reduced - in ...
|
|
Sick released a new product, the safety camera safeVisionary2
With the practical application and demand of security protection, the existing 2D protection equipment has gradually been unable to meet the customer's requirements for safety, and the demand for 3D safety equipment is getting higher and higher.
Today we are launching a new product from SICK---safeVisionary2.
|
|