Sick Sensors - Top 10 Commonly Used Sensors in the Internet of Things
01 Temperature sensor
Temperature sensors measure the heat energy in a heat source, allowing it to detect temperature changes and convert those changes into data.
Machinery used in manufacturing often requires a specific level of ambient and equipment temperature. Similarly, within agriculture, soil temperature is ...
|
|
What are the features of Sick Sensors – Proximity Sensors?
(1) Since the inspection can be carried out in a non-contact manner, it does not wear or damage the object to be inspected.
(2) Since the contactless output method is adopted, the life extension (except for the magnetic type) is made of semiconductors, and the life of the docking point is not affected.
(3) It is not the same as the light detection method.
|
|
A simple explanation and how to use the SICK color scale sensor
The SICK color mark sensor detects a wide range of labels, even if there are subtle differences in the background color, and the processing speed is fast. Automatically adapts to wavelength and is able to detect small differences in grayscale values, regardless of the mixed color of the label and background.
SICK color code ...
|
|
How to adjust the SICK UM18-51112 sensor
Preparation tools: calibrator to change the distance of the ultrasonic sensor, special regulator and special power supply.
Disconnect the power supply: Disconnect the ultrasonic sensor from the controller and prepare it for commissioning.
Commissioning time: The commissioning time can be adjusted to any time to meet the needs of personalization.
|
|
Sick Sensors – How to Choose the Right Color Sensor
1. What is the purpose of the application?
2. What is the type of existing power supply? AC or DC? What is the rated voltage?
3. What equipment should be controlled by the detection system? Conveyor or inspection system?
4. What is the output load?
5. What is the working speed of the required system?
|
|
Sick Sensors - Introduction to the advantages of RTD sensors
(1) High measurement accuracy; The reason why RTD sensors have high measurement accuracy is mainly because the resistance temperature characteristics of some materials are stable and reproducible. Secondly, compared to thermocouples, it does not have the problem of reference end error;
(2) It has a large measurement range, especially in low temperatures;
...
|
|
Sick Sensors – An Introduction to Seven Common Sensors
1. Physical sensor:
A physical sensor is a sensor that detects a physical quantity. It is a device that uses certain physical effects to convert the measured physical quantity into a signal in the form of energy that can be easily processed. There is a definite relationship between the output signal and the input signal. The main physical ...
|
|
Sick Sensors – Precautions for the use of grating displacement sensors
1. Add a protective cover as much as possible, and clean up the chips and oil splashed on the ruler in time to strictly prevent any foreign matter from entering the inside of the grating ruler sensor housing.
2. When plugging and unplugging the grating displacement sensor and the plug holder of the digital display, the power should be turned off.
3. For the extension of the dust seal ...
|
|
Debugging method of Sick fiber optic sensor 180T
1. First, connect the external hardware and install the external COM port of the scanner to the serial port of the industrial computer.
2. The power supply of the SICK scanner control box is 24V positive and negative induction eyes, and the feedback signals of 10, 11 and 12 corresponding to the electric eyes, 24V+, 24V-.
...
|
|
Sick Sensors – the principle and practical application of color mark sensors
Principle:
Contrast sensors are often used to detect spots on specific color marks or objects, and they are used to detect color marks by comparing them to non-color mark areas, rather than directly measuring color. The color mark sensor is actually a reverse device, where the light source is mounted perpendicular to the target object, and the receiver is connected to the ...
|
|
How to set the parameters of the SICK UM30 fiber optic sensor?
1. Connect the device: connect the power supply and electrical signal to the sensor, connect the output interface to the PLC, connect RS232 to the computer, generally use RS232, but also change to other control methods, such as CAN, RS485 and so on.
2. Software installation: Open the laptop, install ...
|
|
A brief introduction to the LFP series, a liquid level sensor from SICK
Its robustness extends its service life
High flexibility, shortened probes and interchangeable connectors
Cost-effective with a wide range of output signals: The same system can be used for spot and continuous level measurement
Commissioning is simple, calibration and maintenance is required
Cancel the measurement ...
|
|
Sick | Cameras from RIBE Technik are used to monitor the assembly facility
Quality assurance through programmable imaging: RIBE Technik from Schwabach has developed an innovative bumper assembly system that includes an inspection system.
Machine vision from SICK enables the identification of individual components and the monitoring of each operating process as a special system concept ...
|
|
Sick releases the Visionary-T Mini AP 3D vision camera
The Visionary-T Mini is a 3D snapshot camera based on TOF (Time-of-Flight) that outputs internally calibrated 2D grayscale images and 3D point cloud data at the same time, helping users reliably identify and locate objects in indoor and semi-outdoor environments.
...
|
|
SICK introduces the magnetic rotation sensor MAS
In the digitalization stage, the first step of the development path of Industry 4.0, Sick is committed to the design and development of intelligent sensors, aiming to lay a solid hardware foundation for digital transformation.
Now, Sick has added a new member to the family of smart sensors – the magnetic corner sensor MAS.
...
|
|
Sick sensors – features of photoelectric sensors
1. Long detection distance
If the detection distance of 10 m or more is retained in the through-beam type, it is possible to achieve detection that is not possible with other detection methods (magnetic, ultrasonic, etc.).
2. There are few restrictions on the detected objects
Due to the detection of shading and reflection caused by the detection of objects ...
|
|
Common fault causes and treatment methods of Sick sensors
1. No weighing reading
This kind of fault is generally more common, the weighing value of a certain scale is zero, regardless of whether there is something on the scale, its weighing value is always zero.
There are several reasons for the above failure: a. the sensor is damaged, b. the line is open, c. the signal is ...
|
|
Sick Sensors – Installation Requirements for RTD Sensors
1. In order to have sufficient heat exchange between the measuring end of the RTD and the medium to be measured, the location of the measuring point should be reasonably selected, and the installation of RTD near the valve, elbow, pipe and equipment should be avoided as much as possible.
2. The thermal resistance with a protective sleeve has heat transfer and heat dissipation loss, in order to reduce the ...
|
|
Sick sensors – the seven basic types of temperature sensors
1. Thermocouples
Thermocouples are voltage devices that indicate temperature measurement when voltage changes. As the temperature increases, the output voltage of the thermocouple increases – not necessarily linear.
Thermocouples are typically located inside a metal or ceramic shield to protect them from exposure to a variety of environments. ...
|
|
Sick Sensors - Analysis of common fault codes for fiber optic sensors
1. Alarm code E401
E401 is one of the common fault codes of fiber optic sensors, which indicates that the fiber optic sensor has detected that the fiber is cracked or bent. This problem can usually be dealt with by replacing the fiber or adjusting the fiber installation orientation.
2. Alarm code E402
...
|