1. Air conditioning load
Office buildings, shopping malls and some supermarkets and factories have central air conditioning, and the electricity consumption of air conditioning is very large during the peak electricity consumption in summer. In hot weather, the electricity consumption of air conditioners in Beijing, Shanghai and Shenzhen accounts for more than 40% of peak electricity. Therefore, using inverter equipment to drag the refrigeration pump, cold water pump and fan of the air conditioning system is a very good power-saving skill. At present, there are many companies specializing in short-term regulation of electricity in the country, during which the primary skill is frequency conversion speed regulation and power saving.
2. Crusher load
Metallurgical mines, building materials use a lot of crushers, ball mills, this kind of load after the selection of frequency conversion effect is significant.
3. Large-scale kiln calciner load
In the past, most of the large-scale industrial converters (converters) such as metallurgy, building materials, and caustic soda used to use DC and commutator motors, slip motors, cascade speed regulation or intermediate frequency unit speed regulation. Because these speed regulation methods may have slip rings or low power, in recent years, many units have chosen frequency conversion control, which has an excellent effect.
4. Compressor load
Compressors also fall under the widely used class of loads. Low-pressure compressors are widely used in various industrial sectors, and high-pressure large-capacity compressors are more used in steel (such as oxygen generators), mines, fertilizers, and ethylene. The selection of frequency conversion speed regulation brings the advantages of small starting current, power saving, and optimization of equipment service life.
5. Rolling mill load
In the metallurgical profession, in the past, large rolling mills mostly used AC-AC frequency converters, in recent years, the selection of AC-DC-AC frequency converters, rolling mill communication has been a trend, especially in light load rolling mills, the selection of general frequency converters, satisfactory low-frequency load starting, synchronous operation between stands, constant tension control, simple and reliable operation.
6. Winch load
The winch load is selected for frequency conversion speed regulation, which is stable and reliable. The blast furnace winch equipment of the iron plant is the primary equipment for transporting raw materials for ironmaking. It requires stable start-up and braking, uniform acceleration and deceleration, and high reliability. Originally, the cascade, DC or rotor string resistance speed regulation method was mostly used, which had low power and poor reliability. Replacing the above-mentioned speed regulation method with a communication inverter can achieve the desired effect.
7. Converter load
For converter loads, the DC unit is replaced by AC frequency conversion, which is simple and reliable, and the operation is stable.
8. Roller table load
Roller table loads, mostly in the iron and steel metallurgy occupation, the use of communication motor frequency control, can improve the reliability and stability of the equipment.
9. Pump load
Pump load, large volume and wide area, including water pumps, oil pumps, chemical pumps, mud pumps, sand pumps, etc., there are low-pressure medium and small capacity pumps, as well as high-pressure and large-capacity pumps.
Many water companies' water pumps, chemical pumps, reciprocating pumps, non-ferrous metal and other occupations of the chemical pump, non-ferrous metal and other occupations of the use of frequency conversion speed regulation, all of which have a very good effect.
10. Cranes and dump trucks
Cranes, dump trucks, etc. have large load torque and require stability, and positive and negative are frequent and reliable. Inverter equipment can meet these requirements by operating cranes and dump trucks.
11. Wire drawing machine load
Wire drawing machines for the production of steel wires require high-speed and continuous production. The steel wire strength is 200Kg/mm2, and the speed control system requires high precision, high stability and synchronization.
12. Transporting vehicle loads
The raw coal loading vehicle of the coal mine or the molten steel transportation vehicle of the steel mill is very good for the use of frequency conversion technology. Fast start and stop, strong overload capacity, flexible forward and reverse rotation, smooth to the coal surface, correct component (no more or less installation), basically do not need manual operation, improve the raw coal production power, save electric energy.
13. Elevator elevated tour car load
Because the elevator is a person-carrying thing, the drag system is required to be highly reliable, and it is necessary to frequently accelerate and decelerate and rotate forward and reverse, and the progress of the dynamic characteristics and reliability of the elevator has increased the sense of safety, comfort and power of the elevator. In the past, the elevator speed regulation was mostly DC, and in recent years, it has gradually switched to communication motor frequency conversion speed regulation, regardless of Japan or Germany.
14. Feeder load
Metallurgy, electric power, coal, chemical industry and other occupations, there are many feeders, whether it is a disc feeder or a vibrating feeder, the use of frequency conversion speed regulation is very significant. The disc feeder of a factory was originally a slip speed regulation, with small low-frequency torque, many faults, and frequent jamming. After the selection of frequency conversion speed regulation, because it is an asynchronous machine, it has high reliability, power saving, and more importantly, the closed-loop temperature transmitter ensures the accuracy of the transported materials, so as not to cause accidents caused by excessive overtemperature of the oxidant transport, and ensures the orderliness of production.
15. Stacker and reclaimer load
The stacker-reclaimer is the primary equipment for stacking materials in coal yards, wharves and mines, and its primary function is to pile and reclaim. The completion of active stacking and semi-active reclaiming, improve the reliability of the equipment, the equipment runs smoothly, there is no impact and shaking phenomenon, the reclaiming process reverses the speed regulation according to the law of 1/cosφ, and improves the reversing reclaiming power of the bucket wheel and the uniformity of the belt coal transportation, which is very popular with workers.
|
More on that
|
The size of the contactor is selected by the type of contactor - LS produces electricity
1. Select the corresponding category of contactor according to the control object, operation times and application category of the contactor.
2. Select according to the rated voltage of the line at the application location.
3. Select the rated current of the main contact of the contactor according to the load capacity.
4. About the voltage level of the lead coil ...
|
|
How to choose LS contactors
The working form of LS contactor:
Generally speaking, after the contactor coil is energized, the entire coil current will generate a magnetic field, which will make the core inside have electromagnetic attraction to attract the core, and make their AC contactor ...
|
|
The inverter selects the appropriate peripheral equipment - LS power generation
After we have selected a suitable Variable-frequency Drive (VFD), we also need to consider whether we need to equip other peripheral equipment according to the actual situation of the site. The peripheral equipment selected by VFD mainly includes circuit breakers, reactors, contactors, braking resistors, etc.
...
|
|
Inverter fault handling - LS power generation
1. The working temperature of the inverter is high
1. Check whether the ambient temperature of the inverter is too high;
2. Check whether the cooling fan inside the device is working normally;
3. Check whether the ventilation pores and mask grilles are blocked;
4. Check if the load is too heavy.
...
|
|
A brief description of the K120S series plc
K120S series PLC product is a unit PLC product introduced to the market by LS in 2004, which has laid a solid foundation in the low-end small machinery supporting industry with its high-performance price ratio. Relying on some special functions of the product, it has also won some industry praise.
...
|
|
Summer maintenance and maintenance of inverter method - LS power generation
1. Check the running status of the inverter, whether the voltage and current value during operation are within the normal range.
2. Carefully monitor and record the ambient temperature of the frequency conversion chamber, which is generally between -5 °C and 40 °C. The temperature rise of the phase-shifting transformer should not exceed 130°C.
3. Prevent ...
|
|
Precautions for the selection of peripheral equipment for LS power inverter
The peripheral equipment of the inverter mainly includes cables, contactors, air switches, reactors, filters, braking resistors, etc. Whether the selection of the peripheral equipment of the inverter is correct and suitable also directly affects the normal operation of the inverter and the service life of the inverter.
|
|
LS inverter series and its features
LS inverter, the full name of LS communication frequency conversion governor, after supplying a variety of equipment, converts direct current into communication electricity, and changes the voltage and frequency of ordinary power supply input to control the speed of the motor, to meet different industrial needs, and then complete the energy saving and environmental protection of the automation system. ...
|
|
Introduction to inverter self-learning motor - LS power generation
1. What is a self-learning motor of inverter?
Enter the motor nameplate (voltage, current, Hz rating) in the inverter parameters, and then the inverter actively measures other parameters of the motor.
Second, why should the inverter learn by itself?
|
|
Application of servo motor - LS power generation
Quick to use:
There are three cables necessary for the operation of the motor: power cable; Motor power line, motor encoder line.
Control line interface X5:
Servo enable necessary pin C24V power supply (7,41) Servo enable SR ...
|
|
Introduction to wiring problems - LS power generation
1. Wiring of fire emergency lighting
Generally, the flame retardant wire is used to wear the metal pipe and the thickness of the protective layer is ≥ 30mm.
|
|
Inverter exception handling method - LS power generation
1. The working temperature of the inverter is high
1. Check whether the ambient temperature of the inverter is too high;
2. Check whether the cooling fan inside the device is working properly;
3. Check whether the ventilation pores and mask grilles are blocked;
4. Check if the load is too heavy.
...
|
|
Dealing with intermittent shutdown fault measures - power generation
Because the touch of the network adapter is not good, perhaps due to disturbance and other problems, the DP network that has been used for a long time may show a "transient disconnection" situation, that is, it will be disconnected by an occasional moment, and it will soon recover normally. If OB86 is not downloaded, the CPU will stop during a transient outage. Now all over the option to download a ...
|
|
The cause and inspection method of inverter overload tripping - LS power generation
1. The main reason for the overload of the inverter
(1) Malfunction, the current detection part inside the inverter has a problem, and the detected current signal is too large, resulting in tripping.
(2) The mechanical load is overloaded, and the main feature of the overload is that the motor heats up, and it can be ...
|
|
Characteristics of single-phase current converter - LS power generation
Single-phase current transmitter is a kind of power test substation developed for the power measurement of single-phase AC in motor test on the basis of motor test and test technology research, in accordance with IEC and relevant national specifications for motor test. The selection of advanced filtering technology, reasonable software algorithms, processing ...
|
|
Introduction to the output frequency of the inverter - LS power generation
1. Maximum frequency fmax, reference frequency fN and reference voltage UN
2. The upper frequency fH and the lower frequency fL
The output frequency of the inverter is limited to the upper and lower limit frequencies to prevent errors in the event of misoperation.
3. Frequency of activation
When the signal ON is activated, the ON ...
|
|
DC motor troubleshooting - LS power generation
1. The speed of the motor slows down, and the cause of the problem of sound disorder may occur in the electronic speed stabilization device and the motor itself. If there is no problem with the power supply, most of the motor itself has a problem. It can be repaired by replacing the new motor and dismantling and repairing the motor. Dismantling and repairing the motor ...
|
|
Common practical knowledge in the inverter industry - power inverter
The inverter is the power frequency power supply (50Hz or 60Hz) converted into various frequencies of AC power supply to achieve the variable speed operation of the motor equipment, by changing the motor power frequency to achieve speed adjustment, is an ideal high-efficiency, high-speed regulation means. Frequency converters are used in industrial production and residential ...
|
|
Manufacturing Automation Terminology – LS Electricity Generation
I/O Points:
When discussing control systems, I/O points are a term that is often heard. It refers to the input/output point, I stands for INPUT, which refers to the input, and O stands for OUTPUT, which refers to the output. The inputs/outputs are for the control system, and the input refers to the ...
|
|
Parameter setting of LS power inverter
Control method: i.e. speed control, rotation control, PID control or other methods. After adopting the control method, it is generally necessary to carry out static or dynamic identification according to the control accuracy and requirements. Low operating frequency: that is, the small speed of the motor running, when the motor is running at low speed, its heat dissipation function ...
|
|