1. The speed of the motor slows down, and the cause of the problem of sound disorder may occur in the electronic speed stabilization device and the motor itself. If there is no problem with the power supply, most of the motor itself has a problem. It can be repaired by replacing the new motor and dismantling and repairing the motor. Dismantling and repairing the motor is mainly to repair the brushes, because the brushes are easy to wear out over time.
2. The motor does not rotate (the internal motor is good) The motor does not rotate, but it runs normally when the power supply voltage is connected to the internal motor, which can be judged to be a fault of the electronic speed stabilization circuit. Because the adjustment transistor in the electronic speed stabilization circuit is damaged, an open circuit phenomenon is formed, resulting in the motor not rotating. Enlarged transistors in steady-speed circuits can sometimes cause this problem as well.
3. The speed of the motor is too fast, and the speed can not be adjusted, most of the problems are due to the short circuit of the adjustment transistor in the electronic speed stabilization circuit, which increases the voltage at both ends of the motor to close to the power supply voltage, and the speed of the motor greatly exceeds the additional speed.
4. The speed is basically normal, but it changes with the change of power supply voltage The reason for the instability of this speed is because there is a problem with the electronic speed stabilization circuit, which is most likely caused by the breakdown of the transistor. This breakdown is also different from a short circuit, in that the transistor is equivalent to a linear resistance between the collector and emitter, and when the applied voltage changes, it is directly applied to both ends of the motor through the fire voltage, so that the motor speed also changes. The same would be true if the transistor expansion factor dropped a lot.
5. The speed of the motor is sometimes normal, but sometimes it is unstable, often because of the poor contact of the trimmer potentiometer used for speed regulation. This kind of potentiometer is often used for a long time, and it will oxidize, form poor contact, sometimes interrupt the phenomenon, or cause instability due to the change of resistance value.
6. The speed oscillates, and the current is shaky, and sometimes the motor runs normally and can also regulate the speed, but after the load is added, the speed oscillates, such as detecting the motor current with an ammeter, and there is a shaky phenomenon. This may be due to a defect in the resistor that regulates the load stabilization rate, and the resistance value becomes larger, causing the positive feedback to be too large. When repairing, it can be replaced with a qualified resistor or connected in parallel with two resistors to make it more reliable.
|
More on that
|
LS GTH, GTK series thermal relay models
Thermal Overload Relay GTH-22
GTH series: GTH-22, GTH-40, GTH-85, GTH-100, GTH-150, GTH-220,
GTH-400、GTH-600、GTH-12M、GTH-12MH、GTH-12M、GTH-MH
GTH series: GTH-22, GTH-40, GTH-85 ...
|
|
The basic problem of LS electric molded case circuit breaker
Rated current of LS molded case circuit breaker:
Now in the process of using molded case circuit breakers, it is necessary to understand the rated current of molded case circuit breakers, and the rated current of molded case circuit breakers generally has more than a dozen, mainly 16A, 25 A, 30A, and the high may reach 630A.
...
|
|
LS power production contactor selection
How LS Contactor Works:
Generally, after the contactor coil is energized, the entire coil current will generate a magnetic field, which will make the core inside have electromagnetic attraction to attract the core, and let their communication contactor point action normally closed contact disconnect, or close, which ...
|
|
Precautions for inverter installation and wiring - LS power generation
The inverter is an electric power control equipment that uses frequency conversion skills and microelectronic skills to control the AC motor by changing the power supply frequency of the motor operation. It is used in a wide range of fields, including conveyors, feeders, mixers, grinders, pulverizers, paper cutters, calenders in various industries...
|
|
The essence and use of LS power PLC module
1. What is PLC?
PLC control system, Programmable Logic Controller, programmable logic controller, a digital operation of electronic devices specially designed for industrial production planning, it uses a class of programmable memory, used in its internal storage program, the execution of logic...
|
|
Analysis of the fault problem of LS power terminal block
From the point of view of application, the function of the terminal block should be achieved: it is necessary to conduct the local conduction of the touch part, and the touch is reliable. The insulating part should not be conducted, and it is necessary to insulate it firmly. There are three common forms of fatal problems in terminal blocks:
...
|
|
Introduction of plc inverter - LS power generation
Because the imported products of the inverter brand have their own PLC function, they mainly play an important role in the control effect of mechanical equipment, and play an important role in the equipment, which can regulate the operation and control of the machine and meet the requirements of users.
It should be scale
pLC ...
|
|
Principle of electrical equipment maintenance - LS power generation
1. Speak before you start
When it comes to faulty electrical equipment, you should not rush into action, but ask about the passage and phenomenon of the fault.
For unfamiliar equipment, you should also understand the circuit principle and structural characteristics, and follow the corresponding rules. Before dismantling, it is necessary to fully understand each ...
|
|
The given way of the inverter - LS generates electricity
Frequency given meaning and given method
The speed of the motor can be changed by changing the output frequency of the inverter. In order to adjust the output frequency of the inverter, the inverter must supply the signal of the changed frequency, which is called the frequency given signal.
|
|
The protection measures of the power generator inverter for the motor
The protection of the motor by the power converter mainly includes the following aspects: overvoltage protection, undervoltage protection, overcurrent protection, phase loss protection, inverter protection, overload protection, grounding protection, short circuit protection, overfrequency protection and stall protection.
...
|
|
Failure analysis of electromagnetic system of LS power production contactor
(1) The core noise is large: it is normal for the electromagnetic system to produce a slight humming sound during operation, if the sound is too loud or abnormal, it can be judged that the electromagnetic system has a problem, and there are three reasons:
(1) Poor contact between the armature and the core or tilting of the armature. After repeated collisions between the touch of the armature and the core, ...
|
|
Inverter harmonic suppression method - LS power generation
1. Install an appropriate reactor
The input side and the output side of the inverter are connected in series with suitable reactors to absorb harmonics and increase the impedance of the power supply or load, so as to achieve the purpose of pressing harmonics to reduce electromagnetic radiation in the transmission process. After pressing the harmonic current, the power factor is changed from the original ...
|
|
LS power production PLC installation and wiring skills
The PLC should be kept away from strong disturbance sources such as electric welding machines, high-power silicon rectifiers and large-scale power equipment, and should not be installed in the same switch cabinet as high-voltage electrical appliances.
Power line, control line and PLC power line and I/O line should be separated from the wiring, barrier transformer and PLC and I/O should be selected ...
|
|
How to choose LS contactors
The working form of LS contactor:
Generally speaking, after the contactor coil is energized, the entire coil current will generate a magnetic field, which will make the core inside have electromagnetic attraction to attract the core, and make their AC contactor ...
|
|
Servo drives and servo motors – LS produces electricity
Driver: Under the premise of carrying out frequency conversion skills, the servo drive has carried out more advanced control skills and algorithm operations than general frequency conversion in the current ring, speed ring and azimuth ring inside the drive (the frequency converter does not have this ring), and it is much stronger than the traditional servo in terms of function.
|
|
Quickly locate the fault method of switching power supply - LS power generation
Due to the short circuit of the load, the failure of the self-oscillation circuit and the loss of control of the protection circuit, the switching power supply will cause the base of the switch tube to be unable to get the switching pulse and intermittent operation, which makes it difficult to locate the shortcomings of SMPS. The difficulty of the repair operation and the improper method will expand the shortcomings, constituting the phenomenon of continuous burning of the switch pipe, etc., ...
|
|
Inverter applications and common loads – LS generates electricity
1. Air conditioning load
Office buildings, shopping malls and some supermarkets and factories have central air conditioning, and the electricity consumption of air conditioning is very large during the peak electricity consumption in summer. In hot weather, the electricity consumption of air conditioners in Beijing, Shanghai and Shenzhen accounts for more than 40% of peak electricity. Therefore, with inverter equipment, drag the air conditioning system ...
|
|
Fatal failure of LS power terminal block
From the point of view of application, the function that should be reached is: it is necessary to conduct the local area where the touch part should be conducted, and the touch is reliable. If the insulating part should not be conducted, it is necessary to insulate it firmly. There are three common fatal problems in terminal blocks:
...
|
|
Inverter circuit structure - LS generates electricity
The main circuit is the power replacement part of the power supply for the asynchronous motor, and the main circuit of the inverter can be roughly divided into two categories: the voltage type is to change the DC of the voltage source to the communication of the DC port of the inverter, and the filter is the capacitor. The current type is to change the DC of the current source to the communication ...
|
|
Specification steps for the safe operation of generator sets – power generation
Standardized procedures for safe operation of generator sets
1. Preparation before starting
(1) The operators of the computer room should abide by the safety operation procedures, wear work clothes and insulated shoes, and the crew should have a clear division of labor.