RRC thermostat - how to adjust the smart thermostat

Create Date: 2024-8-30 12:03:23|Source: RKC

1. Set temperature: Press the SET button to set or view the temperature set point. Press the SET button and the digital tube characters start to flash, indicating that the instrument has entered the setting state, press the △ key to increase the set value, press the ▽ key to decrease the set value, press and hold the △ button or ▽ key The data will change rapidly, and press the SET button again The instrument returns to the normal working state and the temperature is set.

2. Return control (XMT201-C): Press the SET button for 3 seconds to enter the inner parameter setting state. The first parameter that appears and flashes is C00, that is, the return difference value, the return control parameters should be carefully adjusted, the instrument controls the heating output value to the set value, when the temperature falls to the set value and subtracts the difference value, it starts to heat again, and the output (relay) is not active in the return range, so that the relay can reduce the number of actions to prolong the life of the relay. For example, if the setting value is 80.0°C and the return difference is 0.5, the relay is released when the instrument controls the heating to 80.0°C, and the relay is engaged when the temperature drops to 80.0°C-0.5°C=79.5°C. The larger the return difference, the less the relay actions, and the larger the return difference, the control accuracy will be reduced. After adjusting the differential parameters, press the SET button for 3 seconds and the meter returns to normal working state.

3. Advance setting (XMT201-E): Press the SET button for 3 seconds to enter the inner parameter setting state. The first parameter that appears and flashes is E00, that is, the advance amount of heating stop, the advance parameter should be carefully adjusted, in order to reduce the temperature overshoot, the instrument will cut off the heating in advance when controlling the heating output. When the temperature drops below the lead amount, the heating starts again, and the output (relay) does not operate within the range of the set value and the lead amount, so that the number of relay actions can be reduced to prolong the life of the relay. For example, if the setting value is 50.0°C and the advance amount is 0.5, the relay is released when the instrument controls the heating to 49.5.0°C, and the relay is engaged again when the temperature drops to 50.0°C-0.5°C=49.5°C. The larger the advance amount, the fewer the relay actions, and the excessive advance will reduce the control accuracy. After adjusting the advance parameters, press the SET button for 3 seconds and the meter returns to normal working state.

4. Time proportional setting (XMT201-P): Press the SET button for 3 seconds to enter the inner parameter setting state. E: is the proportional band offset, and the E parameter can make the actual control point translate. Even if the center of the time scale shifts, the E value can be positive or negative depending on the heating system. P: is the proportional band, that is, the proportional control value, in order to facilitate understanding and also to make the proportional with a larger representation space, the proportional zone of this instrument is a unilateral proportional band, that is, the actual proportional zone is 2 times the P value. With the actual control point as the center, the output heating ratio is evenly distributed from 0% to 100% in the P-value range. T: For the heating output cycle cycle, that is, the relay working cycle cycle, the T value is small and the control effect is good, but the T value is too small The relay will reduce the life due to frequent work. Generally, the T value is taken for 20-60 seconds. For example, if P is set to 4.0 (the actual proportional band is 8.0), the temperature is set to 60.0 degrees, and E is set to 2.0, the actual control point is 58.0 degrees, and when the temperature reaches 54.0 degrees, the instrument will enter the proportional band control state.

5. Intelligent control parameter setting (XMT201-D): Press the SET button for 3 seconds to enter the inner parameter setting state. E: This parameter is the advance of heating stop when P = 0, when P is not equal to 0, the instrument is the intelligent PID working mode, and when P is not equal to 0, the E parameter is meaningless. P: is the proportional band, that is, the proportional control value, the instrument takes the set value as the center, and the P value is distributed on both sides of the set point, and the instrument works in PID mode within the P value range. T: For the heating output cycle cycle, that is, the relay working cycle cycle, the T value is small and the control effect is good, but the T value is too small The relay will reduce the life due to frequent work. Generally, the T value is taken for 20-60 seconds. To simplify operation, the integration time (I) and derivative time (D) of the meter are designed as hidden parameters, and their default values: I=180, D=45.

6. Correction of error: The displayed value can be corrected when confirming that the value displayed by the instrument is not the correct measured value. Press the SET button for 3 seconds to enter the inner menu of the instrument, the first parameter that appears and flashes is E00, that is, the advance amount, and then press the SET button again to appear and flash the parameter that is the error correction parameter, and this parameter can be modified with the △ or ▽ key. The error correction ranges from -9.9°C to +9.9°C, and after the correction is completed, press the SET button again to exit. The correction value of the meter is 0.0 when it leaves the factory, and it is necessary to prevent the correct meter from being corrected to the wrong point when it is used.
RRC thermostat - how to adjust the smart thermostat

More on that
RK Level Gauge - Four common types of faults and solutions for float level gauges RK Level Gauge - Four common types of faults and solutions for float level gauges

1. The indicated value is large (or out of range). According to the investigation of our staff, this kind of problem often appears in the atmospheric pressure workshop. When we find that the counterweight of the float in the float level gauge is at a low point, the liquid level must be very high at this time, and the glass plate is inconsistent with the indication of the instrument.

RLC Thermostat – Precautions for Thermostat Operation RLC Thermostat – Precautions for Thermostat Operation

1) Measure the function Its temperature measurement scale is mainly between -20 °C and 80 °C, and the humidity measurement scale is mainly between 20% RH and 99% RH. In addition, it has a temperature resolution of 1°C and a humidity of 1%RH. 2) Parameters and data display functions Temperature and humidity control ...

RKC converters – what are the functions of converters? RKC converters – what are the functions of converters?

1. Power conversion: convert the voltage (rated 100V) and current (rated 5A or 1A) of the transformer into voltage (several volts) to meet the requirements of weak current components. 2. Isolation: current, secondary side security, and work grounding are used to ensure the safety of people and equipment, while weak current ...

What should I pay attention to when wiring the RKG thermostat? What should I pay attention to when wiring the RKG thermostat?

1. For thermocouple input, the corresponding compensation wire should be used. 2. For RTD input, 3 wires with low resistance and no difference should be used 3. The input signal line should be far away from the power line of the instrument. Power supply and load lines to avoid noise interference 4. The instrument power cord is usually ...

RHK thermostat - the use of electronic thermostat and its classification introduction RHK thermostat - the use of electronic thermostat and its classification introduction

First, the use of electronic temperature controller The electronic temperature controller (resistive type) is measured by the method of resistance temperature sensing, and generally uses platinum wire, copper wire, tungsten wire and semiconductor (thermistor, etc.) as the temperature measurement resistor, and these resistors have their own advantages and points. Home Air Conditioner ...

RKC thermostat - how to set the parameters of the thermostat? RKC thermostat - how to set the parameters of the thermostat?

1. Lower limit deviation alarm setting: press the SET key to select and display "SLP", the green display screen displays the value of the parameter, and select the shift, increment, and decrement keys to set or modify the parameter. This parameter indicates the difference between the alarm point and the master setpoint. 2. The upper limit deviation alarm is set ...

Introduction to the types of alarms for RKC thermostats Introduction to the types of alarms for RKC thermostats

* Alarm table {ALM1} (standard built-in) A: Upper limit deviation alarm G: Standby upper and lower limit deviation alarm attached B: Lower limit deviation alarm H: Upper limit input value alarm C: Upper and lower limit deviation alarm J: Lower limit input value alarm D: Alarm in the range K: Attached standby ...

RKC level gauge - the fault and treatment method of float level gauge RKC level gauge - the fault and treatment method of float level gauge

Fault 1, the indication is abnormal The float level gauge is not indicated properly and is a very common fault of the float level gauge. Usually there are the following manifestations: Phenomenon 1: The float level gauge in the atmospheric pressure workshop has the largest indication. Troubleshooting: The float was found to be ...

rkc thermostat – five advantages of thermostat over PLC rkc thermostat – five advantages of thermostat over PLC

Programmable logic controllers (PLCs) and temperature controllers (thermostats) offer similar benefits in ensuring effective process control, achieving consistent quality, and minimizing user error in manufacturing. Since the 17th century, process control equipment has been used in a variety of forms.

RHK thermostat - 5 common problems and solutions for stand-alone thermostats RHK thermostat - 5 common problems and solutions for stand-alone thermostats

Fault 1: The thermostat does not turn on (does not light up) Analyze the causes 1. Wrong wiring 2. The voltage of the input terminal is not enough or the input terminal is damaged by empty opening and leakage 3. Whether the cable between the panel and the power board is broken or plugged incorrectly 4. Load short circuit or open circuit, probe ...

RLC Level Gauge - Classification and construction of pontoon level gauges RLC Level Gauge - Classification and construction of pontoon level gauges

1. Classification of pontoon level gauges The pontoon level gauge is also divided into two types: inner pontoon and outer pontoon, the so-called internal and external division refers to the place where the pontoon is installed, in the container of the liquid to be measured is the inner pontoon, and the outer pontoon is called the outer pontoon outside the liquid container to be measured.

RRKC Thermostat – The working principle and main features of the pop-up thermostat RRKC Thermostat – The working principle and main features of the pop-up thermostat

How it works The sudden jump thermostat is a kind of bimetal disc after constant temperature as a heat-sensitive reaction component, when the temperature of the main part of the product increases or decreases, the heat generated is transferred to the bimetal disc, and when the operating temperature is set, it acts quickly, and the contact is broken through the action of the mechanism.

RLC thermostat - common faults of temperature controllers and solutions RLC thermostat - common faults of temperature controllers and solutions

Fault 1: The device does not display after powering on Solution(s): First of all, check whether the terminals of the device have been connected to the neutral live wire, and make sure that the neutral live power supply can work normally. Then start to check whether the cable between the LCD motherboard and the device drive power supply is ...

Analysis of common fault causes of RKC temperature controller Analysis of common fault causes of RKC temperature controller

1. The power indication is normal, but the temperature controller has no screen display. Most of this fault is caused by the heating of the voltage regulator element (7805 or 7812) on the thermostat during long-term use, which causes the solder joint to show a breakpoint, and sometimes it is caused by the phenomenon of virtual soldering at the factory. 2. Temperature controller ...

RKC Thermostat – What are the common faults of thermostats? RKC Thermostat – What are the common faults of thermostats?

1. There is no manifestation when the power is on. For this kind of problem, first confirm whether the power supply is there and whether the power supply matches the power supply required by the thermostat, and then check whether the wiring is strong. The problem is still there, then it is the problem of the thermostat itself. 2. There is a manifestation, and the manipulation makes mistakes. The first thing to look at this kind of problem is to look at the control ...

How to set the parameters of the RCRS400 thermostat How to set the parameters of the RCRS400 thermostat

1. Set temperature: Press the SET button to set or view the temperature set point. Press the SET key digital tube characters to start flashing, indicating that the instrument has entered the setting state, press the △ key to increase the set value, press the ▽ key to decrease the set value, press and hold the △ key or ▽ key The data will change rapidly, press the SET key again ...

RLC Thermostat - Overview and characteristics of mechanical thermostats RLC Thermostat - Overview and characteristics of mechanical thermostats

Mechanical thermostats are suitable for indoor temperature control in industrial, commercial and residential buildings. The mechanical thermostat uses an inflatable diaphragm box to sense the temperature and compare it with the user's set temperature to automatically control the air conditioning equipment to achieve the purpose of indoor constant temperature. For commercial, industrial and civil construction, available ...

The debugging method of the temperature controller The debugging method of the temperature controller

Generally, there are three buttons to provide the need for setting, one is the Set button, press it once to enter the setting state. The other two offer upward and downward temperature adjustments, which can be adjusted to any temperature point. After adjusting to the desired temperature point, press the Set button again to confirm. 1. Turn on the smart thermostat ...

RKC Temperature Control Meter - How to set the temperature control meter RKC Temperature Control Meter - How to set the temperature control meter

1. Turn on the power supply of the smart thermostat, and the temperature displayed on the screen is the temperature at that time. Because the sensor is not in contact with other devices, but is directly exposed to the air clock, this is the current temperature: 31 degrees Celsius, which is not too hot. 2. At the bottom right of the display screen is the "starting temperature" setting ...

RLC Thermostat - Fault and Troubleshooting of Vapor Pressure Temperature Controller RLC Thermostat - Fault and Troubleshooting of Vapor Pressure Temperature Controller

Faulting and troubleshooting of vapor pressure temperature controllers (1) Common faults and common faults of the vapor pressure type temperature controller include contact burning or adhesion, failure of the mechanical transmission mechanism and leakage of temperature sensor in the temperature sensing tube. Its detection method is: put the thermostat knob in a parking position, and use ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top