In general, the DC power supply system is composed of a communication screen, a rectifier screen, and a DC screen. After selecting a dense bus duct, it is necessary to adjust the conventional DC power supply system: one or two large-capacity DC split-screens are installed in the communication room, and a large loop output is set in the DC split-screen; A bus screen is installed in the DC power supply system of the power room, and its function is a dedicated bus output, and no output loop is set in the cabinet; The dense bus duct is selected to connect the DC split screen with the bus link; The power of the DC column head cabinet in the communication room is drawn from the DC split screen in the computer room.
After analyzing the successful application cases of busway in the communication system, the operator chooses the densely distributed insulated busway as the transmission medium of electric energy in the DC power supply system, which can transmit the electric energy to the load side more reliably and safely.
Busway is commonly used in the communication power supply system of high-rise buildings, and the busway is a bus system composed of metal plates (steel plates or aluminum-magnesium alloy plates) to protect the shell, conductive bars, insulating materials and related accessories. According to the insulation method, the bus duct can be divided into three types: air bus duct, dense insulated bus duct and high-strength bus duct.
The densely distributed insulated busway closing bus is produced by the factory in a complete set, with high quality, small operation and maintenance workload, and simple construction device. In addition, the densely distributed insulated bus duct shell is multi-point grounding, so that the shell is basically in the equipotential grounding method, which greatly simplifies the structure and eliminates the risk of personal electric shock.
|
More on that
|
Wiener bus differential protection switching operation
1. Whether the scale of bus differential maintenance is determined, and whether the maintenance goal is unchanged
Generally, differential maintenance includes bus differential maintenance, transformer differential maintenance, generator differential maintenance and line differential maintenance. The basic principle of achieving differential maintenance is common, i.e. on all sides or on each side...
|
|
Power system bus wiring features - Wiener
1) Single bus wiring. Single bus wiring has the advantages of simple and clear, less equipment, small investment, convenient operation and conducive to expansion, but the reliability and flexibility are poor. When there is a fault or maintenance of the bus bar or bus barrier switch, the full power supply of the bus must be disconnected.
...
|
|
Rectangular busbar, trough busbar, and tubular busbar analysis
The rectangular bus has good heat dissipation performance and is easy to fix and connect. But its skin effect is quite large. In order to reduce the skin effect, the cross-sectional area of a single busbar should not exceed 1250 square millimeters. When the working current exceeds the promised current of a single bus, 2 to 4 rectangular buses can be used. Rectangular conductor a ...
|
|
Introduction to the classification of busway - Wiener
According to the different uses of the bus duct, the bus groove is generally composed of the start bus slot, the straight bus slot (no partition jack and jack), the L-shaped straight (horizontal) curve bus, the Z-type straight (horizontal) offset bus, the T-shaped straight (horizontal) tee bus, the X-type straight (horizontal) cross-way bus, the variable ...
|
|
Introduction to the components of the busway - Vernal
Busway is a conductive equipment used for current transmission, and now the higher the building is built, the more the application of busway is required, and in many large foremen, the use of busway is also very economical and reasonable. Any machine is made up of different parts, then the busway is made up of ...
|
|
The Hazards of Arc Light – Wiener Busbar System
The arc of the switchgear cable spacing causes the pressure and temperature in the switchgear to increase rapidly, and if not removed in time, it will cause serious harm in the following aspects:
(1) The arc temperature is 2 times the appropriate solar temperature, and the large ...
|
|
The way in which the Wiener high-voltage busway is selected
In the selection, the following elements should be fully considered: fire protection specifications, insulation layer to flame retardant, good temperature resistance, high temperature is not easy to release harmful gases, structure type to avoid chimney effect, should give priority to the use of aggregate insulation layer bus duct, such as the use of air insulation type, it must be in the electric ...
|
|
Wiener's built-in current transformer
Thanks to the precisely developed housing size, current transformers can now be integrated into all major products in a very space-saving way, such as:
QUADRON®185Power Speed disconnector fuse set
QUADRON®185Power Fuse Isolation ...
|
|
Types of busbars, conditions for the scope of application - Wiener
1. Commonly used busbars, useful categories
Busbars are divided into hard busbars and soft busbars.
According to its different shapes, hard buses can be divided into: rectangular busbars, tubular busbars, trough busbars, diamond busbars and so on.
Rectangular busbars are the most commonly used busbars and are also busbars. According to its material ...
|
|
Calculation method of bus system and distribution cabinet bus - Wiener
The bus system divides the bus into hard bus and soft bus. The 60mm bus system refers to the three-wire or four-wire bus with a distance of 60mm.
1. In the 60mm bus system, the different cross-sectional areas of rectangular copper bars or special-shaped copper busbars such as 2T and 3T can be used to achieve the best classification of current intensity grades.
|
|
Phase of the busway in the low-voltage incoming line – Wiener
According to the requirements of the relevant specifications, the placement of the three-phase busbar can be roughly divided into two kinds according to the model of the low-voltage distribution cabinet and the different manufacturers: horizontal placement and placement of the down wire, according to the order of placement.
|
|
What are the modules of the Wiener bus system?
The modulus of the bus system is 40mm, 60ram, 100/185mm; The bus cross-section is rectangular, double "T" (i.e., "H" shape) and three "T" (i.e., 'state') shapes; The bus system can be three-wire, four-wire or five-wire, or even seven-wire, of course, it should be determined according to the needs ...
|
|
Difference Between Grounding Electrode and Grounding Busbar – Vernal
The grounding electrode is a discharge channel that connects current or voltage to the earth, and in order to reduce the grounding resistance, the electrodes that form the grounding grid are generally used in groups.
The grounding bus refers to the connecting wire that connects the current or voltage to the grounding grid, or the conductor that connects the grounding electrode into one.
...
|
|
Types of corrosion of Wiener tubular busbars
Tubular bus is a new type of equipment that is widely used in our current days, and it itself has the characteristics of high current, outstanding insulation and wide range of application, so we don't seem to be too worried about its function and role when using it. But there is one thing that needs to be ...
|
|
Wiener plug-in busway features
The plug-in busway has a high overload capacity
The overload capacity of the bus duct is strong, depending on the high working temperature of the insulation material it uses, and the working temperature of 105C is selected for the insulation material used in the bus duct, and the radiation cross-linked flame retardant winding tape with a working temperature of more than 140 °C has been developed ( ...
|
|
Vernal fuse replacement method
1. Prepare for replacement. For example, construction personnel should wear labor protection equipment, such as insulating gloves.
2. Confirm the fault type. Check the distribution box with a test pen first, confirm that there is no leakage, and then open the distribution box door. Then use the voltage tester to detect the three-phase power supply, if the three-phase ...
|
|
The role of plug-in busway – Wiener
Generally speaking, plug-in busway is mainly used for power transmission. We know that all conductors will have losses, and the losses caused by the flow of electricity through conductors are larger and some are smaller. For example, compared with the aluminum wire with the same wire diameter and the copper wire, the loss of aluminum is larger, and the loss of copper is smaller. That is, the conductivity ...
|
|
Bus voltage non-system equipment failure and solution
In order to ensure the safe and economical operation of the power system and its power generation, supply and electrical equipment, power grid users require the voltage to operate in three ways: forward voltage regulation, reverse voltage regulation and constant voltage regulation. However, when the power grid is in practice, due to the change of active and reactive power output, the increase or decrease of electricity load, and the system wiring party...
|
|
Introduction to Laminated Busbar System – Wiener
In the power system, the bus connects the various current-carrying branch circuits in the power distribution device together, and plays the role of collecting, distributing and transmitting electric energy; According to the appearance and structure, the bus bar is roughly divided into three categories: hard busbar, soft busbar and closed busbar.
...
|
|
Uses and technologies of cable junction boxes – Wienal
XBT series mine flameproof communication cable distribution box has the characteristics of small size, reasonable cable import and export, and wide coverage. Each distribution box has 4-10 inlet and outlet bells, which is suitable for HUYV type mine signal cable in coal containing sexual gas (methane) mixture (non-mining face).
|
|