Wiener plug-in busway features

Create Date: 2024-8-30 12:03:23|Source: Woehner/Wiehner

The plug-in busway has a high overload capacity

The overload capacity of the bus duct is strong, depending on the high working temperature of the insulation material it uses, and the data with the working temperature of 105C is selected for the insulation material of the bus duct, and the radiation cross-linked flame retardant winding tape (PER) and the radiation cross-linked polycarbon heat shrinkable tube with a working temperature of more than 140 °C have been developed.

Pluggable busway protection is convenient

The busway simply does not need to be protected, the daily protection is usually to measure the temperature rise of the shell and grommet, the temperature rise of the joint of the wire box, etc., if the grommet bolt is selected 4.8 grade, it needs to be tightened regularly, and if the 8.8 grade high-strength bolt is selected, it is not necessary to be strong regularly.

                               Wiener plug-in busway features

Plug-in busway has good heat dissipation

The busway uses air to dissipate heat and dissipate it through a tightly touched steel housing

The plug-in busway prevents overload and misfire

The busway shell is made of steel and will not be incinerated, even if the insulation material of the copper bar is incinerate, the flames will not escape to the outside of the busway.

Pluggable busway tapping is convenient

The so-called plug-in bus duct is that it uses the plug-in method to tap the power supply of the main line to the branch line, so it is convenient to tap.

More on that
Standard parameters of busway specification - Wiener Standard parameters of busway specification - Wiener

1. The standard scale of the bus duct This specification regulates the terminology, skill requirements and test methods of the insulated bus trunk system (bus duct) and its plug-in feed box (hereinafter referred to as the feed box). This specification specification applies to additional voltage AC to 660V...

What is the Wiener bus system What is the Wiener bus system

The Wiener bus system is a standardized system for bus spacing, which is used in low-voltage power supply and distribution switchgear, so that the bus can both conduct electricity and support electrical components. The system is divided into 40, 60, 100 and 185mm systems. ...

What are the specific accessories of the busway - Wiener What are the specific accessories of the busway - Wiener

1. Connecting copper plates, insulating plates, and insulating piercing screws generally refer to tension spring brackets, bus connectors, connecting copper bars, and plug-in boxes. The bracket is used for buffer busbars to squeeze each other during connection, and the adapter is used for connection. The connecting copper bar is the local use of the box and the bus connection of the cabinet connection. ...

Technical requirements for busway system – Wiener busbar Technical requirements for busway system – Wiener busbar

1. The conductor of the bus bar is a high conductivity TMY electrical hard copper bar rolled by T2 electrolytic copper, and the purity of copper must be ≥ 99.95%, and copper-aluminum alloy or other mixed alloy non-pure copper conductor materials shall not be used, and the copper plate is tin plated on the full length. 2. The raw material of the neutral wire and the phase wire in the bus system is the same.

Introduction to several power supply systems – Wienal Introduction to several power supply systems – Wienal

At present, China has five power supply systems: IT, TT, TN-c, TN-c-s and TN-S. They have their own advantages and disadvantages, and we should choose sensitively according to the actual situation in life. Five power supply systems 1.IT power supply system In a ...

Busbar system reverse operation – Wiener Busbar system reverse operation – Wiener

(1) For the charging of the spare bus, when there is a bus tie circuit breaker, the bus tie circuit breaker should be used to charge the spare bus. At this time, the maintenance device of the bus tie circuit breaker should be fully invested, and the relevant maintenance value and time limit should be changed to a small size, so that when there is a problem with the bus, the bus tie circuit breaker can be quickly tripped, cut off...

Features of the use of closed busway - Wiener Features of the use of closed busway - Wiener

Compared with other air-type busway, Wiener closed busway has many similarities in appearance, and its difference lies mainly in the shell, the structure of the closed busway is more distinctive, which also makes its use have certain advantages. As long as it is in contrast ...

Analysis of the product characteristics of Wiener busway Analysis of the product characteristics of Wiener busway

Since the busway is made of copper bars or aluminum as conductors, it has a large current capacity and good electrical and mechanical properties. In addition, it is made of a metal trough as the shell, so it is non-flammable, safe and reliable, and has a long service life. Compared with traditional power distribution or ...

What is the role of the busbar in the distribution box What is the role of the busbar in the distribution box

Busbar refers to a product made of copper and aluminum materials with high conductivity to transmit electrical energy and have the ability to gather and distribute electricity. The main conductor used by the power station or substation to transport electrical energy. In the power system, the busbar in the distribution box connects the various current-carrying branch circuits in the distribution unit, ...

Wiener Electric's busbar system escorts the operation of textile machinery equipment Wiener Electric's busbar system escorts the operation of textile machinery equipment

According to Wiener electrical engineer, the bus system is a process-assisted component, the main effect is to hook the switch on the adapter, and the adapter is then hooked on the copper bar, so that the full protection of the copper bar can be completed, and the safety factor is improved; The upper port of the switch can be connected without ...

The advantage of closed busbar over open busbar is Wiener The advantage of closed busbar over open busbar is Wiener

1) Closing the bus duct can reduce the grounding fault, prevent the short circuit between the phases, and fundamentally eliminate the grounding fault caused by external moisture, dust and foreign objects, and improve the continuity of generator operation. 2) Eliminate the surrounding ...

Introduction to the components of the busway - Vernal Introduction to the components of the busway - Vernal

Busway is a conductive equipment used for current transmission, and now the higher the building is built, the more the application of busway is required, and in many large foremen, the use of busway is also very economical and reasonable. Any machine is made up of different parts, then the busway is made up of ...

Wiener busway plug-in box wiring method Wiener busway plug-in box wiring method

The bus duct bracket has to be firmly installed, and the bus duct should be correctly placed according to the segment sequence number, phase sequence, number, direction and device mark, and when the sections are connected, the adjacent section of the bus duct should be aligned, and the conductor and shell of the bus duct should not accept mechanical stress after the connection. ...

Vernal fuse core Siemens fuse alternative Vernal fuse core Siemens fuse alternative

Due to the long delivery time of the Wiener melt core, whether the Wiener fuse can be replaced by Siemens' fuse, the answer is yes, so it is recommended to use Siemens' Rong Xin, which corresponds to the following 3NA38012C NH-Fuse NH-,00(0 ...

The way in which the Wiener high-voltage busway is selected The way in which the Wiener high-voltage busway is selected

In the selection, the following elements should be fully considered: fire protection specifications, insulation layer to flame retardant, good temperature resistance, high temperature is not easy to release harmful gases, structure type to avoid chimney effect, should give priority to the use of aggregate insulation layer bus duct, such as the use of air insulation type, it must be in the electric ...

Wiener fixed and busbar mounting Wiener fixed and busbar mounting

Precautions for the device VDE 0660 Specification Section 107 / EN 60947-3 Specification / IEC 60947-3 Specification 3 poles are broken at the same time, double breakpoints. Operator-independent, safe opening/closing, in position ...

Rectangular busbar, trough busbar, and tubular busbar analysis Rectangular busbar, trough busbar, and tubular busbar analysis

The rectangular bus has good heat dissipation performance and is easy to fix and connect. But its skin effect is quite large. In order to reduce the skin effect, the cross-sectional area of a single busbar should not exceed 1250 square millimeters. When the working current exceeds the promised current of a single bus, 2 to 4 rectangular buses can be used. Rectangular conductor a ...

The essence of Wiener busbar technology The essence of Wiener busbar technology

1. Closed busbar hooking technology Circuit breakers and contactors can be hooked on the bus through the bus adapter, and fuse switches and other products are directly attached to the bus, so the bus bar plays a two-layer effect of conductive and fixed rotation.

Low-voltage cabinets need temperature and humidity controllers for the reason - Vernal Low-voltage cabinets need temperature and humidity controllers for the reason - Vernal

Why is the temperature and humidity controller of the low-voltage cabinet? The application field of low-voltage cabinet is very wide, high-voltage switchgear should be one of the key electrical equipment and equipment for electromagnetic energy production scheduling and transportation, there will be some simple reasons to form high-voltage switchgear hot in specific work, low-voltage cabinet I remind you that at this time ...

Vernal fuse replacement method Vernal fuse replacement method

1. Prepare for replacement. For example, construction personnel should wear labor protection equipment, such as insulating gloves. 2. Confirm the fault type. Check the distribution box with a test pen first, confirm that there is no leakage, and then open the distribution box door. Then use the voltage tester to detect the three-phase power supply, if the three-phase ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top