Thanks to the precisely developed housing size, current transformers can now be integrated into all major products in a very space-saving way, such as:
QUADRON®185Power Speed disconnector fuse set
QUADRON®185Power fuse disconnector
CRITO®185Power Adapter Element
EQUES®185Power adapter
and current transformer modules
The current transformer does not need anything to install it, and the current transformer has a frame terminal suitable for the cable, so that the appropriate type of cable can be installed in a standardized manner. The housing structure of the current transformer is symmetrically planned, so it can be used for the measurement of the incoming and outgoing terminals.
Benefits at a glance
Integrated into QUADRON®185Power Speed disconnector fuse sets, QUADRON®185Power disconnectors, CRITO®185Power adapters, EQUES®185Power adapters and current transformer modules
The cable can be easily attached to the bottom
The device is simple and requires nothing
Can be sealed
Current transformers for all common current classes, from 80 A to 1600 A
Thanks to the symmetrical housing structure, the current transformer can be used for measurement at the feed end or at the outlet end.
Accuracy class 1 and accuracy classes 0.5 and 0.5S for billing use
Frame terminals, 2.5 mm² - 4 mm²
|
More on that
|
Introduction to the components of the busway - Vernal
Busway is a conductive equipment used for current transmission, and now the higher the building is built, the more the application of busway is required, and in many large foremen, the use of busway is also very economical and reasonable. Any machine is made up of different parts, then the busway is made up of ...
|
|
How to choose the right fuse - Wiener
1. Select the type of fuse according to the line requirements and installation conditions. Circuits with small capacity are semi-enclosed or enclosed without fillers; The selection of large short-circuit current has a packing closed type; Semiconductor component maintenance selection of quick fuses.
...
|
|
Wiener fixed and busbar mounting
Precautions for the device
VDE 0660 Specification Section 107 / EN 60947-3 Specification / IEC 60947-3 Specification
3 poles are broken at the same time, double breakpoints.
Operator-independent, safe opening/closing, in position ...
|
|
There are several main ways to wiring the Wiener bus
Bus line refers to a product made of copper (copper bar) and aluminum material with high conductivity to transmit electrical energy and have the ability to collect and distribute electricity. The main conductor used by the power station or substation to transmit electrical energy. Through it, the output of the generator, transformer or rectifier ...
|
|
Busway installation method - Wiener
1. Busway horizontal device, the interval between the two brackets is ≯2500mm, and the interval between straight devices is ≯3600mm;
2. When the device bracket is straight, it should be drilled with the channel side plate and fastened with M6-M8 bolts.
3. In the process of installation construction, priority should be given to the power supply system, ...
|
|
Busbar system reverse operation – Wiener
1. For the charging of the spare bus, when there is a bus tie circuit breaker, the bus tie circuit breaker should be used to charge the spare bus. At this moment, the maintenance device of the bus tie circuit breaker should be fully invested, and the relevant maintenance value and time limit should be changed to a smaller one, so as to facilitate the bus tie circuit breaker when there is a problem, the bus tie circuit breaker can quickly trip, cut ...
|
|
Aluminum alloy busway circuit continuity - Wiener
The continuity of the aluminum alloy bus duct maintenance circuit is related to the PE line, and the crossover PE wire conductor bus of the maintenance conductor and the two-unit bus bar should reach 50% of the phase line, the equivalent cross-sectional area. The continuity resistance of the housing and PE line maintenance circuit is ≤ 0.005 ohm female, and the unit with jumper wire is not less than the maintenance conductor.
|
|
A detailed description of the Wiener comb busbar and connection terminals
The Wiener comb busbars and connection terminals are available with QUADRON®CrossLinkBreaker in size 000/00
Recommended installation: Wire entry at the lower end of the NH-fuse disconnector through the comb busbar.
In the installation position and ...
|
|
Wiener busway plug-in box wiring method
The bus duct bracket has to be firmly installed, and the bus duct should be correctly placed according to the segment sequence number, phase sequence, number, direction and device mark, and when the sections are connected, the adjacent section of the bus duct should be aligned, and the conductor and shell of the bus duct should not accept mechanical stress after the connection.
...
|
|
What are the modules of the Wiener bus system?
The modulus of the bus system is 40mm, 60ram, 100/185mm; The bus cross-section is rectangular, double "T" (i.e., "H" shape) and three "T" (i.e., 'state') shapes; The bus system can be three-wire, four-wire or five-wire, or even seven-wire, of course, it should be determined according to the needs ...
|
|
Wiener busway specification standard parameters
1. The standard scale of the bus duct
This specification regulates the terminology, skill requirements and test methods of the insulated bus trunk system (bus duct) and its plug-in feed box (hereinafter referred to as the feed box).
This specification specification applies to additional voltage AC to 660V...
|
|
What are the hazards of 220V DC in the bus system - Wiener
The grounding of the DC system should include two situations: the one-point grounding of the DC system and the two-point grounding of the DC system.
In the DC system, the positive and negative poles of DC are insulated from the ground, and there is no grounding current when generating a ground current when one pole is grounded.
|
|
Introduction to the classification of busway - Wiener
According to the different uses of the bus duct, the bus groove is generally composed of the start bus slot, the straight bus slot (no partition jack and jack), the L-shaped straight (horizontal) curve bus, the Z-type straight (horizontal) offset bus, the T-shaped straight (horizontal) tee bus, the X-type straight (horizontal) cross-way bus, the variable ...
|
|
Features of busway power supply system - Wiener
1. Trunk power distribution system, simple wiring and reliable operation.
2. It is convenient to tap, and you can tap without cutting off the main power supply. Large power supply capacity up to 6300A current-carrying capacity.
3. High dielectric strength, strong overload, superior fire performance. Good heat dissipation performance, low impedance ...
|
|
Power system bus wiring method - Vernal
(1) Single busbar. Single busbar, single bus segment, single bus plus bypass, and single bus segment plus bypass.
(2) Double busbar. Double-busbar, double-busbar segmentation, dual-busbar plus bypass, and dual-busbar segmentation plus bypass.
(3)3/2 wiring ...
|
|
Introduction to busbars, busway, and busbridges - Wiener
generatrix
In the field of electricity, the busbar can also be called the busbar, busbar, etc., which mostly refers to the busbar or power supply trunk in the high and low voltage cabinet, which is used to connect multiple electrical lines. The system will install various interface cards through the bus, and transmit various data to the devices connected to the interface cards.
|
|
Comparison of several insulated tubular busbars
The use of insulated tube bus in China has a history of nearly 20 years, and it has made a historic contribution to reducing the layout space of the distribution bus and improving the reliability of the bus operation. There are many manufacturers who supply this product, and their production processes are uneven, and the differences in processes are mainly reflected in the ...
|
|
Low-voltage dense busway uses and applications
Densely insulated bus duct (hereinafter referred to as bus duct) can be communication three-phase three-wire, three-phase four-wire, three-phase five-wire system, frequency 50-60Hz, voltage to 400V, rated operating current of 250-5000A, mainly as a new type of power supply and distribution equipment in industrial and mining, enterprises and high-rise buildings. Mother with insertion day ...
|
|
The difference between busway and busbar - Vernal
The busway and busbar are actually closed one after the other, and the other is not closed.
Closing the busbar is referred to as the busway, which means that the busway is the vest that closes the busbar, and the closing busway and the busbar refer to the same thing.
...
|
|
Advantages of installing cable trays with busway – Wiener
When it comes to cable tray installation, wiring is not very convenient. This phenomenon can be avoided by using busway. The 5 advantages of using busway in the cable tray device are as follows:
1. Convenient connection of bus duct: the so-called plug-in bus duct, fireproof bridge is the way it uses plugged in.
|
|