Generally speaking, plug-in busway is mainly used for power transmission. We know that all conductors will have losses, and the losses caused by the flow of electricity through conductors are larger and some are smaller. For example, compared with the aluminum wire with the same wire diameter and the copper wire, the loss of aluminum is larger, and the loss of copper is smaller. That is, the conductivity is different. The electrical conductivity of copper is relatively high. We also know that the larger the cross-sectional area of copper, the greater the amount of electricity transmitted. Household wires are copper wires with an insulating coat on the outside. Because the family's requirements for electricity are not very large, the general copper wire can supply electricity for everyone.
If it is a large workshop, the current needs to be several thousand amperes. Then, the current that can be supplied by this copper wire is far from enough, at this time, the copper bar will come into play, because the cross-sectional area of the copper bar is larger and can carry more current. The protective shell is covered on the outside of the copper bar, which is the fundamental prototype of the plug-in bus duct. Now, let's understand the effect of plugged busway. That is, it can supply a larger current as needed, up to a maximum of 6300A.
In addition, in addition to the plug-in bus duct can supply large current, its own structure can make it particularly convenient to take power from the bus, only need to use the plug-in box to plug in the plug-in bus duct power port, you can. Plug-in busway is divided into air plug-in busway and dense plug-in busway. And there are three-phase four-wire and three-phase five-wire.
|
More on that
|
Busway installation method - Wiener
1. Busway horizontal device, the interval between the two brackets is ≯2500mm, and the interval between straight devices is ≯3600mm;
2. When the device bracket is straight, it should be drilled with the channel side plate and fastened with M6-M8 bolts.
3. In the process of installation construction, priority should be given to the power supply system, ...
|
|
The use of busbar systems – Wiener busbars
First, this kind of small electrical equipment is a novel concept, adopting the "non-hole lap technology", and the electrical equipment is directly installed on the confluence bus system to form a power distribution or control loop. The representative creations are busbar device fuses and fuse load disconnectors.
...
|
|
What are the characteristics of the bus wiring method of the power system?
(1) Single bus wiring. Single bus wiring has the advantages of simplicity and clarity, less equipment, less investment, and convenient operation and expansion, but its reliability and activity are poor. When the bus or bus separator is faulty or overhauled, all power to the bus must be disconnected.
...
|
|
Introduction to the Wiener 3-pole adapter
1、32590
EQUES®30Compact
Bus adapter 32 A
1 adjustable support rail
45 x 160 with conductor AWG 10 (6 mm²)
2、32591
EQUES®30Compact
Bus adapter 63 A
1 ...
|
|
The Hazards of Arc Light – Wiener Busbar System
The arc of the switchgear cable spacing causes the pressure and temperature in the switchgear to increase rapidly, and if not removed in time, it will cause serious harm in the following aspects:
(1) The arc temperature is 2 times the appropriate solar temperature, and the large ...
|
|
Introduction to busbars in Wiener's electrical system
The bus bar is an intermediate link in the voltage distribution device at all levels, and its role is to gather, distribute and transmit electric energy. It is mainly used for the connection of the electrical main circuit between the power plant generator outlet line and the main transformer, the plant transformer and the distribution box, also known as the busbar.
...
|
|
The common DC bus of the inverter system - Wiener
1. Three-phase AC power supply inlet
The power input of each inverter is connected in parallel on the same AC bus, and the power supply phase of the input of each inverter is consistent. In Figure 3, the circuit breaker QF is the incoming protection device for each inverter. LR is an incoming reactor, when multiple inverters are in the same ...
|
|
Introduction to the advantages of busway - Wiener
The advantage of the busway is that its structural design is simple, it is composed of metal plates, which can connect the circuits together, so as to achieve the safe and reliable transmission of electric energy. In addition, its structural design can effectively assist in reducing the occurrence of short circuits, reducing heat loss, and can effectively ensure the power ...
|
|
Ship unloader distribution cabinet convergence mode - Wiener
In the hardware layout planning of the ship unloader distribution cabinet, in order to omit the wiring slot pawn, save time and effort in wiring, prevent wiring errors, and make the distribution cabinet beautiful and useful, the circuit breaker inlet end in the distribution cabinet will use the confluence method. Here are a few commonly used ways to combine the flow with Siemens circuit breakers.
|
|
Considerations for purchasing a busbar system – Wiener
The bus system plays a very important role in the practice of construction, and for products such as the bus system, the relevant items can not be ignored, so that we can better use the practical value of this type of product. Generally speaking, when we are purchasing a bus system ...
|
|
Scenarios for the use of various types of busbars - Vernal
1. The bus bar is divided into hard bus bar and soft bus bar.
2. According to different shapes, hard busbars can be divided into: rectangular busbars, tubular busbars, trough busbars, diamond busbars, etc.
3. Rectangular busbar is a commonly used busbar. According to its material ...
|
|
The advantage of busway over cable in construction - Wienal
Modern power supply lines play a very important role like the aorta of the human body, and if something goes wrong, it can have serious consequences. Before the 80s of the 20th century, many stable cables were used in modern construction. With the rapid development of the city, the power load of the building ...
|
|
Aluminum alloy busway circuit continuity - Wiener
The continuity of the aluminum alloy bus duct maintenance circuit is related to the PE line, and the crossover PE wire conductor bus of the maintenance conductor and the two-unit bus bar should reach 50% of the phase line, the equivalent cross-sectional area. The continuity resistance of the housing and PE line maintenance circuit is ≤ 0.005 ohm female, and the unit with jumper wire is not less than the maintenance conductor.
|
|
Example of the application of the Wiener busbar system
The motor control cabinet uses the Wiener bus system, and the copper bus is used as both a hooking element and a conductive element; The incoming molded case circuit breaker is connected to the copper bar through a special bus adapter, and all the motor maintenance switches and contactors are hooked on the bus adapter in an orderly manner.
|
|
Comparison of several insulated tubular busbars
The use of insulated tube bus in China has a history of nearly 20 years, and it has made a historic contribution to reducing the layout space of the distribution bus and improving the reliability of the bus operation. There are many manufacturers who supply this product, and their production processes are uneven, and the differences in processes are mainly reflected in the ...
|
|
Performance characteristics of low-voltage busbar system - Wienal
Introduction to the performance of low-voltage bus system:
1. The bus bar is not perforated, and is connected with the cable and copper bar through the connection clip or terminal
2. Switches, contactors and other electrical components can be directly hung on the bus through adapters
3. Save ...
|
|
What are the modules of the Wiener bus system?
The modulus of the bus system is 40mm, 60ram, 100/185mm; The bus cross-section is rectangular, double "T" (i.e., "H" shape) and three "T" (i.e., 'state') shapes; The bus system can be three-wire, four-wire or five-wire, or even seven-wire, of course, it should be determined according to the needs ...
|
|
Difference Between Busbar and Cable in Power System – Wiener
Busbar refers to a product made of copper (copper bar) and aluminum materials with high conductivity to transmit electric energy and have the ability to gather and distribute electricity. The main conductor used by the power station or substation to transmit electrical energy. Through it, the electrical energy output from generators, transformers or rectifiers is delivered to individual users.
|
|
Wiener bearing repair technology
1. Comprehensive correction of bearings
The comprehensive correction of the bearing includes the comprehensive and strict correction process of the damaged bearing after cleaning, dismantling, inspection, roller table grinding or replacement of inner and outer rings, new rolling element manufacturing/original rolling element grinding, rolling element replacement, assembly, clearance adjustment and inspection and packaging.
|
|
Rectangular busbar, trough busbar, and tubular busbar analysis
The rectangular bus has good heat dissipation performance and is easy to fix and connect. But its skin effect is quite large. In order to reduce the skin effect, the cross-sectional area of a single busbar should not exceed 1250 square millimeters. When the working current exceeds the promised current of a single bus, 2 to 4 rectangular buses can be used. Rectangular conductor a ...
|
|