Vernal fuse replacement method

Create Date: 2024-8-30 12:03:23|Source: Woehner/Wiehner

1. Prepare for replacement. For example, construction personnel should wear labor protection equipment, such as insulating gloves.

2. Confirm the fault type. Check the distribution box with a test pen first, confirm that there is no leakage, and then open the distribution box door. Then use the voltage tester to detect the three-phase power supply, if the three phases are electrified, the wiring screws of the fuse seat need to be detected, if there is electricity at one end and no electricity at the other end, it means that the fuse has been burned.

                            Vernal fuse replacement method

3. Start replacing the fuse. First, power off the distribution box, and rotate the spiral fuse cover to remove it in the counterclockwise direction, check the fuse core, and the fuse wire has been burned out. Then check whether the copper card in the fuse holder and the gland has any signs of burning, if so, dispose of the black charcoal inside, and replace the new fuse.

4. Detect the fuse. After the fuse is replaced, use the electric tester pen to test the power supply at both ends of the fuse holder, if there is electricity at both ends, it means that it has been replaced.

5. Use quizzes. Close the door of the distribution box, release the brake, press the start button to start the pump, if the motor rolls up, it means that the fuse is successfully replaced.

More on that
Technical features of Wiener closed busbar Technical features of Wiener closed busbar

The out-of-phase shut-off bus adopts a fully connected structure, with optimized design, reasonable design, stable and reliable operation. Choose either natural cooling or forced air cooling. The out-of-phase closing bus is to support the conductors of each phase bus with insulators and close them in their respective shells, and the shells themselves are electrically connected, ...

The difference between the busbar system and the traditional wiring The difference between the busbar system and the traditional wiring

The advantages of the busbar system are: 1. The Wiener bus system adopts the bus bar non-perforation connection technology, and the electrical components are firmly connected to the busbar; 2. It saves the device space, saves the redundant wiring, saves the device time and labor; 3. The busbar ...

Wiener bus adapter features: Wiener bus adapter features:

Functional aspects The bus bar is made of copper or aluminum, which has high current density, small resistance and small skin effect, and does not need to be used for capacity reduction. The small voltage drop also means that the energy loss is small, which ultimately saves the user's capital. As far as the cable is concerned, because the cable core is a multi-strand thin copper wire, its root surface ...

Power system bus wiring method - Vernal Power system bus wiring method - Vernal

(1) Single busbar. Single busbar, single bus segment, single bus plus bypass, and single bus segment plus bypass. (2) Double busbar. Double-busbar, double-busbar segmentation, dual-busbar plus bypass, and dual-busbar segmentation plus bypass. (3)3/2 wiring ...

Some of the Wiener series models Some of the Wiener series models

  05802 Insulator with female thread, bolt, M8, height 35mm 08824 Platen connector for PE- and N-busbar 01 932   08825 Snap-on fastener, for PE- and N-busbars 01126-01129 and 019 ...

185Power - The solution for the 185mm busbar system 185Power - The solution for the 185mm busbar system

Since the launch of the 185Power system in 2014, Wiener has continued to develop new connection technologies and fuse-type disconnector technologies for the 185Power system on the basis of the 185mm bus technology. In addition to the application of 1600A below ...

Difference Between Busbar and Busway – Vernal Difference Between Busbar and Busway – Vernal

The connection of voltage distribution devices at all levels in the substation, as well as the connection of electrical equipment such as transformers and corresponding distribution devices, mostly use bare wires or stranded wires of rectangular or circular cross-section, which are collectively referred to as busbars. The role of the bus bar is to collect, distribute and transmit electrical energy. Because the busbar ...

Busbar system segmentation understanding - Wiener Busbar system segmentation understanding - Wiener

The so-called "section" of the bus bar is that the data that constitutes the bus are directly connected, and there is no circuit breaker or blocking switch in the center. A circuit breaker or barrier switch in the center is called a "segment". Different voltage levels cannot be connected in the same section. No...

Use and characteristics of AC busbar systems – Wiener Use and characteristics of AC busbar systems – Wiener

The communication and connection skills of the independent power supply system create better prospects for the power supply of the future. Hundreds of systems around the world have installed SMA's Sunny Island battery inverters to supply power to customers for a long time. The stackability of Sunny Island, i.e. multiple Sunny Islands ...

Temperature rise requirements and safety of Wiener busway Temperature rise requirements and safety of Wiener busway

With the rapid development of our economy and technology, the trend of urbanization is becoming more and more popular, and people's electricity consumption is also increasing. In this case, the busway has developed significantly, and the use of instead of cable has become the development trend of the times. Therefore, what are the requirements for the temperature rise of the busway and ...

Introduction to the Wiener data center bus system Introduction to the Wiener data center bus system

Although the service life cost of the bus system is usually lower than that of the traditional wiring method, the bus system still bears a considerable cost compared with other structural elements of the water supply and drainage or HVAC system. In addition, customized busbar equipment allows the busbar system to be routed around obstacles ...

Introduction to several power supply systems – Wienal Introduction to several power supply systems – Wienal

At present, China has five power supply systems: IT, TT, TN-c, TN-c-s and TN-S. They have their own advantages and disadvantages, and we should choose sensitively according to the actual situation in life. Five power supply systems 1.IT power supply system In a ...

Rectangular busbar, trough busbar, and tubular busbar analysis Rectangular busbar, trough busbar, and tubular busbar analysis

The rectangular bus has good heat dissipation performance and is easy to fix and connect. But its skin effect is quite large. In order to reduce the skin effect, the cross-sectional area of a single busbar should not exceed 1250 square millimeters. When the working current exceeds the promised current of a single bus, 2 to 4 rectangular buses can be used. Rectangular conductor a ...

How to optimize the busbar system of the computer room - Wiener How to optimize the busbar system of the computer room - Wiener

In today's information society, the computer room is a very common equipment, so the most important thing in a computer room is the bus system, which is the center and skeleton of the power distribution of the entire computer room. Then a reasonable bus system will greatly improve the efficiency of the equipment room. So how do you optimize ...

Low-voltage dense busway uses and applications Low-voltage dense busway uses and applications

Densely insulated bus duct (hereinafter referred to as bus duct) can be communication three-phase three-wire, three-phase four-wire, three-phase five-wire system, frequency 50-60Hz, voltage to 400V, rated operating current of 250-5000A, mainly as a new type of power supply and distribution equipment in industrial and mining, enterprises and high-rise buildings. Mother with insertion day ...

The advantages of low-voltage closed busbar system without punching connections The advantages of low-voltage closed busbar system without punching connections

1. Save space. The components are attached to the busbar, which can save 1/3 of the size of the box transformer. 2. Operation**. The busbars are placed behind the components, and the upper and lower plates can be sealed to prevent touch protection. 3. Improve the stability and reliability of operation, improve the dynamic and thermal stability, and the bus bar is not perforated.

Applications in the power of busbar systems – Vernal Applications in the power of busbar systems – Vernal

The bus refers to the connection of voltage transformers and other voltage distribution devices at all levels in the substation, as well as the connection of electrical equipment such as transformers and corresponding distribution devices, and most of the bare wires or stranded wires with rectangular or circular cross-sections are selected. Follow the lines ...

How to solve the fault of the busway How to solve the fault of the busway

If there is a problem in the bus duct of the double bus wiring, it is necessary to pay attention to the operation mode of bus maintenance in the process of dealing with the problem, and if necessary, the bus maintenance should be stopped for a short time. After the bus voltage disappears, the dispatcher should immediately swing the switch (including the bus tie switch) that may call, and notify the operation team to ...

Busbar system reverse operation – Wiener Busbar system reverse operation – Wiener

1. For the charging of the spare bus, when there is a bus tie circuit breaker, the bus tie circuit breaker should be used to charge the spare bus. At this moment, the maintenance device of the bus tie circuit breaker should be fully invested, and the relevant maintenance value and time limit should be changed to a smaller one, so as to facilitate the bus tie circuit breaker when there is a problem, the bus tie circuit breaker can quickly trip, cut ...

Aluminum alloy busway circuit continuity - Wiener Aluminum alloy busway circuit continuity - Wiener

The continuity of the aluminum alloy bus duct maintenance circuit is related to the PE line, and the crossover PE wire conductor bus of the maintenance conductor and the two-unit bus bar should reach 50% of the phase line, the equivalent cross-sectional area. The continuity resistance of the housing and PE line maintenance circuit is ≤ 0.005 ohm female, and the unit with jumper wire is not less than the maintenance conductor.

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top