Direct transformation method
The direct conversion method is to synthesize the "output voltage" through the continuous chopper of the input voltage, which can be divided into coordinate transformation method, harmonic injection method, equivalent conductivity method and scalar method, although all these methods have certain advantages, but also have certain problems, limiting their application scope. For example, the input phase current waveform of the scalar method is better, but the output harmonic is larger.
Current tracking method
This method compares the three-phase output current signal with the measured output current signal, and determines the switching action according to the comparison results and the current switching power supply state, which has the characteristics of easy to understand, simple implementation, fast response, good robustness, etc., but also has the common shortcomings of hysteresis current: the switching frequency is not stable enough, the harmonics are randomly distributed, and the input current waveform is not ideal, and there are large harmonics.
Indirect transformation method
Space vector modulation technology, also known as indirect transformation method, AC-DC-AC equivalent transformation method, is a method based on space vector transformation, which virtualizes the AC-AC transformation into AC-DC and AC transformation, so that the popular high-frequency rectification and high-frequency PWM waveform synthesis technology can be adopted, and the performance of the converter can be greatly improved. Of course, the rectification and inverter are completed in one step, and the lower harmonics are well suppressed, but the control scheme is more complex and lacks effective dynamic theoretical analysis support. It is a more researched and mature control strategy in matrix converters, and it is more promising. This modulation strategy can control both the output waveform and the input current waveform, and can change the input power factor, which is the most promising modulation strategy.
|
More on that
|
RHK thermostat – a rapid detection method for common air conditioner thermostats
1. Bellows or diaphragm air conditioner thermostat
1. Fault phenomenon: poor contact or burning, resulting in the circuit can not be connected; The frequent action of the contact arc and sticking causes the circuit to be unbreakable; The thermostat in the temperature sensing chamber leaks, causing the contact to fail to operate and lose control.
...
|
|
RLC thermostat - common faults of temperature controllers and solutions
Fault 1: The device does not display after powering on
Solution(s):
First of all, check whether the terminals of the device have been connected to the neutral live wire, and make sure that the neutral live power supply can work normally. Then start to check whether the cable between the LCD motherboard and the device drive power supply is ...
|
|
RLC thermostat - common faults and solutions of intelligent temperature controllers
1. Heating for a period of time, the temperature does not change. Displays the ambient temperature of the site at all times (e.g. room temperature 25°C)
In case of such failures, first check whether the SV value setting value is set, whether the instrument OUT indicator is lit, and whether the No. 3 and 4 terminals of the "multimeter" measuring instrument have 12VDC output.
|
|
RKC Level Gauges - Advantages and Disadvantages of Several Common Level Gauges Introduction
1. Float level gauge is an instrument that relies on the principle of buoyancy to measure the liquid level. Usually by means of a float in conjunction with a scale, the observer can visually read the height of the liquid level.
Advantages: fast and intuitive reading; Low price; Easy to install.
Shortcoming:...
|
|
How the thermostat works – RKC
Thermostat, according to the temperature change of the working environment, physical deformation occurs inside the switch, so as to produce some special effects, a series of automatic control elements that produce on-on or off-action actions, or different principles of electronic components at different temperatures and working states to give ...
|
|
RKC thermostat - how to prevent freezing and heat preservation of instruments in winter?
In winter, the surface of the power plant's measuring instruments is frozen and condensed, which can lead to poisoning, fire and even explosion. Therefore, the cold and freeze protection of the appearance of the instrument is particularly important.
First, the selection method
(1) Choose the appearance with insulation device. According to the category of appearance ...
|
|
Introduction to the types of alarms for RKC thermostats
* Alarm table {ALM1} (standard built-in)
A: Upper limit deviation alarm G: Standby upper and lower limit deviation alarm attached
B: Lower limit deviation alarm H: Upper limit input value alarm
C: Upper and lower limit deviation alarm J: Lower limit input value alarm
D: Alarm in the range K: Attached standby ...
|
|
RK thermostat - the use and adjustment of temperature control instruments
1. Set temperature: Press the SET button to set or check the temperature set point. Press the SET button at the beginning of the digital tube character flashing, indicating that the appearance has entered the setting state, press the △ key to add the set value, press the v key to decrease the setting value, press and hold the △ key or √ key The data will change rapidly, press the SET key again ...
|
|
RLC Thermostat - Fault and Troubleshooting of Vapor Pressure Temperature Controller
Faulting and troubleshooting of vapor pressure temperature controllers
(1) Common faults and common faults of the vapor pressure type temperature controller include contact burning or adhesion, failure of the mechanical transmission mechanism and leakage of temperature sensor in the temperature sensing tube. Its detection method is: put the thermostat knob in a parking position, and use ...
|
|
RKC Level Gauge – Key points for using a float level gauge
1. The level gauge is adjusted normally, and it is found that the float is "absorbed" for a period of time in a certain position after it is put into use. This is mainly caused by the level gauge passing through the steel platform device and being spaced too close to the steel plate. Therefore, it is necessary to pay special attention to the level gauge to connect the pipe wall with the steel platform device.
|
|
RKG thermostat – how the temperature controller sets the parameters
1. Lower limit deviation alarm setting: press the SET key to select and display "SLP", the green display screen displays the value of the parameter, and select the shift, increment, and decrement keys to set or modify the parameter. This parameter indicates the difference between the alarm point and the master setpoint.
2. The upper limit deviation alarm is set ...
|
|
RKC thermostat Digital display controller parameter setting method
A digital display controller is a simple controller with indication, control, remote transmission and alarm functions. As a secondary instrument commonly used in sensors, it is very important to operate and use it correctly. Applications such as level control, temperature control, pressure control and parameter value display of measured variables. ...
|
|
Initialization parameter setting of the rkc thermostat
1. Press the ISET) button for 2 seconds to enter the parameter setting mode, press ISET until "LCK" is displayed, press the [] key to move the cursor to the thousands, and press the [] button to change the number of thousands from "0" to "1" to display "1000" to unlock.
2. Press the ISET button for 3 seconds to return to SV/PV display mode
3. Press [SET]+ ...
|
|
How to set the parameters of RKC thermostat CD901?
1. Lower limit deviation alarm setting: press the SET key to select and display "SLP", the green display screen displays the value of the parameter, and select the shift, increment, and decrement keys to set or modify the parameter. This parameter indicates the difference between the alarm point and the master setpoint.
2. The upper limit deviation alarm is set ...
|
|
RKC Thermostat – How can a thermostat be broken?
First, the temperature does not appear
1. Fault with the temperature sensor
If the temperature probe of the temperature sensor breaks or the wire is broken, the sensor does not have a digital display when the temperature sensor is connected, but only shows the "----" and sounds an alarm.
|
|
RKG thermostat - an introduction to the relevant knowledge of temperature controllers
The temperature controller is an electrical switchgear that controls the temperature of an air-conditioned room. The temperature range in the air-conditioned room controlled by the temperature controller is generally 18°C--28°C. The temperature controller commonly used in window air conditioners uses the principle of pressure to push the contacts on and off. Its structure consists of bellows ...
|
|
RRKC Thermostat – The solution to the failure of the jump thermostat switch
1. The cleanliness and finish of the contact surface have a great impact on the working state of the contact. When the appearance of the contact is rough or there is residue on the contact, it is easy to cause arcing and reduce the life of the contact. Therefore, the parts cleaning process should be improved to eliminate the residues; Add the process of residue selection, ...
|
|
Parameter setting operation of RLC temperature control table CH402
Model: CH402FS01-8*HN (for PECVD temperature control)
1) Single press SET: SV can be set (set temperature manually)
2) Press and hold the SET button for 2 seconds, ALI=1000 (absolute alarm temperature setting) and then press the SET button, ATU=1 (self-defining, self-interpreting a set of PID parameters) to exit ...
|
|
RKC thermostat How to quickly understand the wiring diagram of the thermostat
There are many models of temperature controllers, and the output methods are slightly different, but the wiring principle is the same.
The working principle of the thermostat: the main circuit of the power supply is directly connected to the heating device through the main contact of the AC contactor.
|
|
RKC Thermostat The structure, action principle and use of some commonly used relays
A relay is an electrical appliance that works automatically. When the amount of electricity such as voltage, current, and frequency or non-electricity such as temperature, pressure, and rotational speed is input to the relay, and when the specified value is reached, the contacts of the relay connect or cut off the circuit that controls or protects it. Relays are widely used in motor control and power ...
|
|