RKC Level Gauges – Precautions for Level Gauges

Create Date: 2024-8-30 12:03:23|Source: RKC

The correct selection of the level gauge can ensure the better use of the level gauge. What kind of level gauge should be selected according to the physical and chemical properties of the fluid medium to be measured? What is the diameter of the level gauge, the flow range, the lining material, the electrode material, and the output current? All of them can adapt to the nature of the measured fluid and the requirements of flow measurement.

1. Precision function inspection

Accuracy grade and function according to the measurement requirements and use occasions to select the instrument accuracy level, so as to achieve economic and cost-effective. For example, when it is used for trade settlement, product handover and energy metering, a higher accuracy level should be selected, such as 1.0, 0.5, or higher; For the occasion of process control, different accuracy levels are selected according to the control requirements; For those who only need to detect the process flow and do not need to do precise control and measurement, you can choose a slightly lower accuracy level, such as 1.5, 2.5, or even 4.0, and then you can choose a low-cost plug-in level gauge.

2. Measurable medium

Measuring medium flow rate, instrument range and caliber When measuring general media, the full flow rate of the level gauge can be selected in the range of 0.5-12m/s of the flow rate of the measuring medium, and the range is relatively wide. The selection of instrument specifications (caliber) is not necessarily the same as the process pipeline, should depend on whether the measured flow range is determined in the flow rate range, that is, when the pipeline flow rate is low, can not meet the requirements of the flow meter or when the measurement accuracy can not be guaranteed under this flow rate, the instrument caliber needs to be reduced, so as to improve the internal flow rate, and obtain satisfactory measurement results.
RKC Level Gauges – Precautions for Level Gauges

More on that
RKC Level Gauge - the principle of the selection of float level gauges RKC Level Gauge - the principle of the selection of float level gauges

The float level gauge is widely used, mainly used in petroleum processing, food processing, chemical industry, water treatment, manufacturing, electric power, papermaking, metallurgy, ships and boilers and other industrial automation processes to measure and control the level. 1. Pay attention to the specific working conditions. As introduced ...

RLC thermostat - common faults and solutions of intelligent temperature controllers RLC thermostat - common faults and solutions of intelligent temperature controllers

1. Heating for a period of time, the temperature does not change. Displays the ambient temperature of the site at all times (e.g. room temperature 25°C) In case of such failures, first check whether the SV value setting value is set, whether the instrument OUT indicator is lit, and whether the No. 3 and 4 terminals of the "multimeter" measuring instrument have 12VDC output.

RLC Level Gauge - Classification and construction of pontoon level gauges RLC Level Gauge - Classification and construction of pontoon level gauges

1. Classification of pontoon level gauges The pontoon level gauge is also divided into two types: inner pontoon and outer pontoon, the so-called internal and external division refers to the place where the pontoon is installed, in the container of the liquid to be measured is the inner pontoon, and the outer pontoon is called the outer pontoon outside the liquid container to be measured.

RHK thermostat – a rapid detection method for common air conditioner thermostats RHK thermostat – a rapid detection method for common air conditioner thermostats

1. Bellows or diaphragm air conditioner thermostat Fault Symptom: Poor contact or burning, resulting in the circuit cannot be connected; The frequent action of the contact arc and sticking causes the circuit to be unbreakable; The leakage of the thermostat in the temperature sensing chamber causes the contact to fail to operate and lose control ...

RRKC thermostats – how are temperature controllers wired and commissioned? RRKC thermostats – how are temperature controllers wired and commissioned?

1. Take out the room temperature controller, and then connect the power supply terminal of the temperature controller to the power supply according to the terminal diagram of the temperature control chart 2. Then take out the temperature sensor that comes with the temperature controller and detect it 3. According to the temperature controller terminal, the temperature sensor is connected to the controller's transmission.

Introduction and wiring method of Japan physical and chemical RKC thermostat Introduction and wiring method of Japan physical and chemical RKC thermostat

  The core control algorithm of the temperature regulator is PID control, P (Proportional) ratio + I (Integral) point + D (Differential) differential control. In addition to the traditional PID control algorithm, RKC also has ON-OFF control, custom parameter control, adaptive parameter control and other algorithms, ...

Precautions for the use of RKC thermostats Precautions for the use of RKC thermostats

fold When the RKC thermostat comes out, it is a single-loop regulator, that is, it only has a heating function, which is called the basic meter, which is generally sent to the agent, and the agent will expand the multi-channel adjustment and alarm output control function, which is called "changing the meter" in the industry, so as to ensure that there is very little hardware cost.

RRKC Thermostat – The working principle and main features of the pop-up thermostat RRKC Thermostat – The working principle and main features of the pop-up thermostat

How it works The sudden jump thermostat is a kind of bimetal disc after constant temperature as a heat-sensitive reaction component, when the temperature of the main part of the product increases or decreases, the heat generated is transferred to the bimetal disc, and when the operating temperature is set, it acts quickly, and the contact is broken through the action of the mechanism.

RTC thermostat - how to set the parameters of the thermostat RTC thermostat - how to set the parameters of the thermostat

1. Lower limit deviation alarm setting: Press the SET key to select and display "SLP", the green display screen displays the value of the parameter, and select the shift, increment, and decrement keys to set or modify the parameter. This parameter indicates the difference between the alarm point and the master setpoint. 2. The upper limit deviation alarm is set ...

RKC Level Gauge – The correct maintenance method for float level gauges RKC Level Gauge – The correct maintenance method for float level gauges

(1) After 6 months to 1 year of operation, the sensor should be visually inspected and routinely calibrated. (2) Regularly check whether the sensor is bent and deformed by external force to avoid ball jamming. (3) Regularly check whether the magnetic induction switch element of the sensor is aging and failing, ...

How the thermostat works – RKC How the thermostat works – RKC

Thermostat, according to the temperature change of the working environment, physical deformation occurs inside the switch, so as to produce some special effects, a series of automatic control elements that produce on-on or off-action actions, or different principles of electronic components at different temperatures and working states to give ...

RKC Level Gauge – Some installation requirements for pontoon level gauges RKC Level Gauge – Some installation requirements for pontoon level gauges

1. The installation of the level gauge must be vertical to ensure that the inner pontoon can move up and down freely in the pipe body. 2. Install a shut-off valve between the container and the liquid level gauge to clean and overhaul the liquid level timing to cut off the material. 3. No magnets are allowed to approach around the main body of the pontoon level gauge, otherwise ...

Causes and treatment methods of inverter overvoltage Causes and treatment methods of inverter overvoltage

 1. According to the theory of cutting off the overvoltage, when the transformer is cut off, the current in the transformer inductance cannot be abruptly changed, and the stored magnetic field energy forms a vibration between the excitation inductance of the transformer and the ground capacitor, and the overvoltage occurs. 2. Transformer ...

RKC thermostat - common faults and solutions of temperature control instruments RKC thermostat - common faults and solutions of temperature control instruments

1. Heating for a period of time, the temperature does not change. The ambient temperature of the site (e.g. room temperature 25°C) is displayed at all times. In case of such failures, first check whether the SV value setting value is set, whether the 0UT indicator light of the meter is lit, and whether the No. 3 and No. 4 terminals of the meter with the "multimeter" are 12VD ...

RLC Thermostat - Introduction to the function of mechanical temperature control RLC Thermostat - Introduction to the function of mechanical temperature control

1. The temperature setting is set by the knob, which is convenient and intuitive 2. It can be directly installed on the standard junction box on the wall. 3. Beautiful appearance and reliable performance. 4. The switch adopts toggle type, which feels comfortable and has a long life. 5. It can control two-wire or three-wire electric (ball...

Common faults and failure analysis of RTC thermostats Common faults and failure analysis of RTC thermostats

1. The power indication is normal, but the temperature controller has no screen display. Most of this fault is caused by the heating of the voltage regulator element (7805 or 7812) on the thermostat during long-term use, which leads to the breakpoint of the solder joint, and sometimes it is caused by the phenomenon of virtual soldering at the factory, and the main re-soldering can be done. 2. Temperature controller ...

RKC Level Gauge – How to install a buoy level gauge RKC Level Gauge – How to install a buoy level gauge

1. Welding and installation of the lower support of the guide wire: determine the position at the bottom of the container according to the requirements of the movement direction of the float of the level gauge, and weld or rivet the lower support of the fixed guide wire. If the equipment does not have welding conditions, the heavy anchor fixing method can be used to fix the guide wire under the support. For example, the liquid level wave in the container ...

RK thermostat - the problem that should be paid attention to in the installation of floor heating thermostat RK thermostat - the problem that should be paid attention to in the installation of floor heating thermostat

1. Wall installation, the height is about 1.2 meters, generally on the same horizontal line as the electric lighting switch of the home. 2. Installed on a wall where the surrounding air flows freely, and is not affected by other heat sources (e.g. sunlight), air flow from doors and windows, or external wall temperature, etc. 3. Advance ...

RKC Thermostats – How to Choose a Thermocouple? RKC Thermostats – How to Choose a Thermocouple?

The selection of thermocouples should be based on comprehensive considerations such as the operating temperature range, the required accuracy, the operating atmosphere, the performance of the measured object, the response time and the economic benefits. 1. Selection of measurement accuracy and temperature measurement range 1) The operating temperature is 1300-1800°C, and the accuracy is required to be more accurate than ...

RKC Level Gauge – The correct way to use the float level gauge RKC Level Gauge – The correct way to use the float level gauge

(1) Before use, first check whether the level gauge is within the verification cycle, otherwise, it should be calibrated, and replaced in time if it is unqualified. (2) The sensor should be installed horizontally, and the length of the lower entry should meet the technical requirements. (3) The connection between the sensor and the explosion-proof junction box should be tightened and tightened.

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top