1. Float level gauge is an instrument that relies on the principle of buoyancy to measure the liquid level. Usually by means of a float in conjunction with a scale, the observer can visually read the height of the liquid level.
Advantages: fast and intuitive reading; Low price; Easy to install.
Disadvantages: low accuracy; The installation is limited by the shape and structure of the container; It is not suitable for use in corrosive and dangerous media; Remote transmission and adjustment are not possible.
The 2.Ci flap level gauge relies on a magnetic float installed inside the container to drive the magnetic flap outside the container to flip to achieve signal conversion and liquid level display.
Advantages: fast and intuitive reading; The price is lower; It can realize remote transmission and adjustment.
Disadvantages: low accuracy; Complex installation; range limitations; The installation volume is relatively large.
3. The capacitive liquid level sensor uses the change of capacitance between the two plates of the capacitor to measure the level of the liquid level.
Advantages: small size, easy to achieve remote transmission and adjustment; Suitable for corrosive and high-pressure media.
Disadvantages: The dielectric constant of the medium and the upper part of the liquid level must be kept constant in order to be accurately measured; The measuring range is limited by the length of the metal rod; There are high requirements for container materials; The medium to be measured is electrically conductive.
4. The radar level gauge converts the liquid/object surface position by detecting the information reflected by the liquid surface of the microwave (electromagnetic wave with a very short wavelength) emitted by itself.
Advantages: It can measure the liquid level in the pressure vessel, and can ignore the influence of high temperature, high pressure, fouling and condensate; High accuracy; No direct contact with the medium; Strong corrosion resistance; Can be used in a vacuum environment; Easy to install.
Cons: Expensive; Affected by container geometry and material properties; It is susceptible to electromagnetic interference.
5. The ultrasonic level gauge converts the liquid/object surface position by detecting the signal after the ultrasonic wave emitted by itself is reflected by the liquid surface.
Advantages: no direct contact with the medium; Strong corrosion resistance; High accuracy; Easy to install.
Cons: The price is relatively expensive; Ultrasonic waves are greatly affected by the gas composition of the transmission medium; It is greatly affected by the geometric structure characteristics of the container; Not suitable for media with bubbles or suspended solids; It is susceptible to electromagnetic interference.
|
More on that
|
RKC converter - an introduction to the classification of converters
Analog-to-digital converters
The analog-to-digital converter comprises a first transmission circuit, which receives an input voltage and an output clock signal, which is phase-shifted, depending on the input voltage, and a second transmission circuit receives a reference voltage and an input clock signal, and outputs a reference clock signal, which ...
|
|
Parameter setting operation of RLC temperature control table CH402
Model: CH402FS01-8*HN (for PECVD temperature control)
1) Single press SET: SV can be set (set temperature manually)
2) Press and hold the SET button for 2 seconds, ALI=1000 (absolute alarm temperature setting) and then press the SET button, ATU=1 (self-defining, self-interpreting a set of PID parameters) to exit ...
|
|
RKC thermostat REX-C400 model settings and parameter instructions
Japan RIKA RKC REX-C400 temperature controller product introduction
REX-C400 Digital Thermostat RKC PID Temperature Controller Thermostat (SSR Output) + Type K Thermocouple + *Large 40A SSR Relay
1. Dual display set temperature and process temperature
2. General Digital Programmable Temperature ...
|
|
RLC Thermostat - Overview and characteristics of mechanical thermostats
Mechanical thermostats are suitable for indoor temperature control in industrial, commercial and residential buildings. The mechanical thermostat uses an inflatable diaphragm box to sense the temperature and compare it with the user's set temperature to automatically control the air conditioning equipment to achieve the purpose of indoor constant temperature. For commercial, industrial and civil construction, available ...
|
|
RRC thermostat - how to adjust the smart thermostat
1. Set temperature: Press the SET button to set or view the temperature set point. Press the SET button digital tube characters to start flashing, indicating that the instrument has entered the setting state, press the △ key to increase the set value, press the ▽ key to decrease the set value, long press the △ key or ▽ key The data will change rapidly, press the SET key again ...
|
|
RK Level Gauge - Typical Fault Problems and Solutions of Pontoon Level Gauges
1. There is no liquid level display or lower liquid level display
When the sewage is discharged, only a small amount of condensate flows out, and it is judged that the pontoon is blocked.
Treatment: Dismantle the outer pontoon and find that the pontoon is almost filled with dirt and impurities. Clean, calibrate, and return to normal.
2. The liquid level display is ...
|
|
RKC Thermostat – What are the common faults of thermostats?
1. There is no manifestation when the power is on. For this kind of problem, first confirm whether the power supply is there and whether the power supply matches the power supply required by the thermostat, and then check whether the wiring is strong. The problem is still there, then it is the problem of the thermostat itself.
2. There is a manifestation, and the manipulation makes mistakes. The first thing to look at this kind of problem is to look at the control ...
|
|
RLC thermostat - common faults and treatment methods of dry-type transformer thermostats
1. There is no display of dry-type transformer thermostat
Cause of failure: (1) The power supply of the thermostat is not connected; (2) The fuse is blown out.
Solution: (1) Turn on the power supply; (2) Replace the fuse.
2. The dry-type transformer thermostat shows that one or three phases are flashing and displays "-OP-"
...
|
|
RKC Level Gauges – Precautions for Level Gauges
The correct selection of the level gauge can ensure the better use of the level gauge. What kind of level gauge should be selected according to the physical and chemical properties of the fluid medium to be measured? What is the diameter of the level gauge, the flow range, the lining material, the electrode material, and the output current? can adapt to the ...
|
|
RKC Level Gauge – Key points for using a float level gauge
1. The level gauge is adjusted normally, and it is found that the float is "absorbed" for a period of time in a certain position after it is put into use. This is mainly caused by the level gauge passing through the steel platform device and being spaced too close to the steel plate. Therefore, it is necessary to pay special attention to the level gauge to connect the pipe wall with the steel platform device.
|
|
The main technical indicators of RKC thermostat
The main technical indicators of RKC thermostat
· Input: various thermocouple (TC), RTD standard current and voltage signals (see input type table);
· basic error: 0.5% of the input full-scale ±±1 word;
· Resolution: 1°C, 0.1°C;
...
|
|
RKC level gauge - buoy level gauge structure composition
The level gauge is composed of five parts: float, traction cable, guide pulley, hammer pointer, display ruler or magnetic flap.
1. Float: The float is welded with two stainless steel (or carbon steel) fasting cones and one stainless steel (or carbon steel) fasting cylinder.
|
|
RKC Level Gauge – The structure of a float level gauge
(1) For the indicator, also known as the display panel, the indicator plays the role of local display, convenient for long-distance observation of the actual situation of the liquid level, the indicator is generally bundled with the pontoon, easy to install.
(2) It is a magnetic float, which is located in the pontoon and is in direct contact with the liquid to be measured, ...
|
|
RKC thermostat - what are the anti-interference measures of the instrument?
1. Electromagnetic induction (refers to the coupling of magnetism). There is a strong alternating magnetic field in the surrounding space of high-power transformers, AC motors, high-current power grids, etc., and the closed loop formed by the lines of the control system (detection, transmission, conversion, regulation, calculation, execution, auxiliary, display, etc.) is located in the ...
|
|
RLC Level Gauge - Classification and construction of pontoon level gauges
1. Classification of pontoon level gauges
The pontoon level gauge is also divided into two types: inner pontoon and outer pontoon, the so-called internal and external division refers to the place where the pontoon is installed, in the container of the liquid to be measured is the inner pontoon, and the outer pontoon is called the outer pontoon outside the liquid container to be measured.
|
|
How to set the parameters of the RKC rs400 thermostat?
1. Set temperature: Press the SET button to set or check the temperature set point. Press the SET key digital tube character start flashing, indicating that the appearance has entered the setting state, press the △ key to increase the set value, press the ▽ key to decrease the set value, press and hold the △ key or ▽ key data will change rapidly, press the SET key again ...
|
|
RKG thermostat - an introduction to the characteristics of digital displays
1) It is a display of the common cathode. It uses the principle of the positive electrode as the segmented input, with the ground wire as the common output, and the segmented input is valid as a high-level input.
2) It is a display with a common anode. It uses an anode as an aggregate input, and in contrast to the common cathode, the segment is effective at a low level output ...
|
|
How to set the parameters of the RKC fb900 thermostat
Model definition
FB90②③*④4⑤⑥⑦⑧⑨-0(
CODE 8N-4*4NN5/A1-F801/Y
control
"(1)(2)" indicates Output 1 and Output 2 classes
M: Relay output V: Voltage pulse output 5: 0-10V
8: 4-20mAN: No output
“ ...
|
|
RLC thermostat – what you should pay attention to when maintaining your temperature controller
1. Do not wipe with acidic, alkaline and other corrosive liquids and water-containing rags when cleaning, so as not to damage the temperature controller and affect its normal use.
2. Do not decorate and cover the temperature controller. The thermostat has a built-in temperature sensor to sense the outside temperature. Therefore, Wen ...
|
|
RKC thermostat - what should be paid attention to when maintaining the thermostat?
1. Do not wipe with acidic, alkaline and other corrosive liquids and water-containing rags when cleaning, so as not to damage the temperature controller and affect its normal use.
2. Do not decorate and cover the temperature controller. The thermostat has a built-in temperature sensor to sense the outside temperature. Therefore, Wen ...
|
|