RLC Thermostat – Instructions for installation and use of pop-up thermostats

Create Date: 2024-8-30 12:03:23|Source: RKC

1. Grounding method: It is connected to the grounding metal parts of the equipment through the metal cover of the thermostat.

2. The thermostat should work in the general indoor environment where the relative humidity of the air is not more than 90%, and there are no corrosive gases, flammable gases and conductive dust.

3. When the thermostat adopts contact temperature sensing, the cover should be close to the heating part of the controlled device, and the thermal grease or other thermal conductive medium with similar performance should be coated on the temperature sensing surface of the cover.

4. When the thermostat is in contact with liquid or steam, it is recommended to use stainless steel capped products, and there should be reliable leak-proof measures to prevent the liquid from seeping into the insulating parts of the thermostat.

5. Do not collapse or deform the top of the cover, so as not to change the operating temperature or affect other performance.

6. Do not let the liquid penetrate into the inside of the thermostat! The housing must be protected from excessive force to prevent cracks; The housing should be kept clean to prevent contamination by conductive substances to avoid short-circuit breakdown due to reduced insulation properties.

7. The terminal block cannot be bent during use, otherwise the reliability of the electrical connection will be affected.

8. The power supply shall not exceed the declared voltage and current, and the load power and type shall meet the declared requirements, and the ambient temperature shall not exceed the declared maximum allowable temperature.

Precautions (KSD301 manual reset): After the temperature drops by 20 °C, the reset handle can be pressed, and the force is 4-6 Newtons, not too large. In order to ensure that the thermostat can work normally, the vertical distance from the end face of the reset handle to the temperature sensing surface of the cover is not less than 20.4mm.
RLC Thermostat – Instructions for installation and use of pop-up thermostats

More on that
RHK thermostat - the thermostat shows the reasons for the deviation between the temperature and the actual temperature and the solution RHK thermostat - the thermostat shows the reasons for the deviation between the temperature and the actual temperature and the solution

The thermostat shows a nonlinear relationship between the temperature and the actual temperature deviation: (1) The input type of the thermostat is selected incorrectly; (2) There is no calibration or calibration error in the analog input; (3) There is interference in the thermostat; (4) There is interference with thermocouples; (5) The use of quality is not ...

RKC thermostat How to quickly understand the wiring diagram of the thermostat RKC thermostat How to quickly understand the wiring diagram of the thermostat

There are many models of temperature controllers, and the output methods are slightly different, but the wiring principle is the same. The working principle of the thermostat: the main circuit of the power supply is directly connected to the heating device through the main contact of the AC contactor.

Initialization parameter setting of the rkc thermostat Initialization parameter setting of the rkc thermostat

1. Press the ISET) button for 2 seconds to enter the parameter setting mode, press ISET until "LCK" is displayed, press the [] key to move the cursor to the thousands, and press the [] button to change the number of thousands from "0" to "1" to display "1000" to unlock. 2. Press the ISET button for 3 seconds to return to SV/PV display mode 3. Press [SET]+ ...

The main technical specifications of the RKG thermostat The main technical specifications of the RKG thermostat

Input: all kinds of thermocouple (TC), RTD standard current and voltage signals (see input type table); Basic error: 0.5% of the input full-scale ±±1 word; Resolution: 1°C, 0.1°C; Sampling period: 3 times/sec Alarm function: ...

What should I pay attention to when operating the RKC thermostat? What should I pay attention to when operating the RKC thermostat?

The instrument can be cleaned only after the power is off; To remove stains from the monitor, use a soft cloth or cotton paper; The display is easy to be scratched, and it is forbidden to use hard objects to operate the panel buttons, otherwise the keys will be damaged or scratched. ...

RKC converter – the design essentials of the power converter RKC converter – the design essentials of the power converter

In the design of power converter, firstly, the circuit topology is determined according to the load requirements, and the composition and backup mode of the power converter are determined, and the main parameters of the power converter are input voltage range, output voltage accuracy, load stability, voltage stability, output ripple, efficiency and dynamic.

RHK thermostats – an introduction to the classification of displays RHK thermostats – an introduction to the classification of displays

(1) Categorize by display color 1. Monochrome display There are two types of displays: multi-grayscale monochrome display and VGA multi-frequency monochrome display. These displays are small, lightweight, clear and inexpensive, making them suitable for highly mobile workplaces. 2. Color ...

RHK thermostat - the use of electronic thermostat and its classification introduction RHK thermostat - the use of electronic thermostat and its classification introduction

First, the use of electronic temperature controller The electronic temperature controller (resistive type) is measured by the method of resistance temperature sensing, and generally uses platinum wire, copper wire, tungsten wire and semiconductor (thermistor, etc.) as the temperature measurement resistor, and these resistors have their own advantages and points. Home Air Conditioner ...

RKC thermostat REX-C400 model settings and parameter instructions RKC thermostat REX-C400 model settings and parameter instructions

Japan RIKA RKC REX-C400 temperature controller product introduction REX-C400 Digital Thermostat RKC PID Temperature Controller Thermostat (SSR Output) + Type K Thermocouple + *Large 40A SSR Relay 1. Dual display set temperature and process temperature 2. General Digital Programmable Temperature ...

RKC Thermostat – What are the common faults of thermostats? RKC Thermostat – What are the common faults of thermostats?

1. There is no manifestation when the power is on. For this kind of problem, first confirm whether the power supply is there and whether the power supply matches the power supply required by the thermostat, and then check whether the wiring is strong. The problem is still there, then it is the problem of the thermostat itself. 2. There is a manifestation, and the manipulation makes mistakes. The first thing to look at this kind of problem is to look at the control ...

RKC Level Gauge – Four mounting methods for buoy level gauges RKC Level Gauge – Four mounting methods for buoy level gauges

1. The buoy level gauge is welded and installed under the guide wire At the bottom of the container, determine the position according to the requirements of the movement direction of the level gauge buoy, and weld or rivet the support under the fixed guide wire. 2. Buoy level gauge ruler installation 1. The connecting part of the ruler should be flat.

How to set the parameters of RKC thermostat CD901? How to set the parameters of RKC thermostat CD901?

1. Lower limit deviation alarm setting: press the SET key to select and display "SLP", the green display screen displays the value of the parameter, and select the shift, increment, and decrement keys to set or modify the parameter. This parameter indicates the difference between the alarm point and the master setpoint. 2. The upper limit deviation alarm is set ...

RKC thermostat – the correct way to adjust the thermostat RKC thermostat – the correct way to adjust the thermostat

1. Set temperature: Press the SET button to set or view the temperature set point. Press the SET key digital tube character start flashing, indicating that the appearance has entered the setting state, press the △ key to increase the set value, press the ▽ key to decrease the set value, press and hold the △ key or ▽ key The data will change rapidly, press the SET key again The appearance will return ...

RK thermostat - the use and adjustment of temperature control instruments RK thermostat - the use and adjustment of temperature control instruments

1. Set temperature: Press the SET button to set or check the temperature set point. Press the SET button at the beginning of the digital tube character flashing, indicating that the appearance has entered the setting state, press the △ key to add the set value, press the v key to decrease the setting value, press and hold the △ key or √ key The data will change rapidly, press the SET key again ...

A few things to note about the installation of the RKC thermostat A few things to note about the installation of the RKC thermostat

1) For RTD input, 3 wires with low resistance and no difference should be used. 2) The input signal line should be far away from the power line of the instrument, the power supply line and the load line to avoid noise and annoyance. 3) The power cord of the instrument is generally annoyed by the power supply. 4) Instrument complement ...

RHK thermostat - 5 common problems and solutions for stand-alone thermostats RHK thermostat - 5 common problems and solutions for stand-alone thermostats

Fault 1: The thermostat does not turn on (does not light up) Analyze the causes 1. Wrong wiring 2. The voltage of the input terminal is not enough or the input terminal is damaged by empty opening and leakage 3. Whether the cable between the panel and the power board is broken or plugged incorrectly 4. Load short circuit or open circuit, probe ...

RLC thermostats – the classification of thermostats and their detailed introduction RLC thermostats – the classification of thermostats and their detailed introduction

1. Sudden jump thermostat The type of various sudden thermostats is collectively called KSD, such as KSD301, KSD302, etc., the thermostat is a new type of bimetal thermostat, mainly as a variety of electric heating products with overheat protection, generally connected with the thermal fuse in series, sudden temperature ...

RRKC thermostats – the commissioning steps of mechanical thermostats RRKC thermostats – the commissioning steps of mechanical thermostats

1. Confirm the angle sample first. See where the angle of the sample is today. 2. Pick up the thermostat, first confirm whether the switch of the thermostat is tight, stuck, whether the white dot falls off, whether there is sound when the thermostat contacts are in contact, and if there is no sound, there should be two possibilities! ...

How to set the parameters of the RKC fb900 thermostat How to set the parameters of the RKC fb900 thermostat

Model definition FB90②③*④4⑤⑥⑦⑧⑨-0( CODE 8N-4*4NN5/A1-F801/Y control "(1)(2)" indicates Output 1 and Output 2 classes M: Relay output V: Voltage pulse output 5: 0-10V 8: 4-20mAN: No output “ ...

RRKC Thermostats – Considerations for Instrumentation Maintenance and Maintenance RRKC Thermostats – Considerations for Instrumentation Maintenance and Maintenance

There are many types of instrumentation and have a wide range of applications in many fields. Because of this, there are many problems with the failure of instruments in the process of use, so it is necessary to pay more attention to the repair and maintenance of instruments and meters, which can effectively improve the performance of instruments and meters, and can extend the performance of instruments and meters.

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top