Yaskawa arc welding robot reported that the voltage detection line was abnormal

Create Date: 2024-8-30 12:03:23|Source: YASKAWA/Yaskawa

1. First turn off the power - and pull down the power switch.

2. Secondly, use a pen to check the voltage feedback line of the cable behind the base of the robot to see if it is connected or loose.

3. Finally, confirm the abnormality for maintenance. Other error alarm codes can also be resolved according to the abnormal message content under the welder.
Yaskawa arc welding robot reported that the voltage detection line was abnormal

More on that
The main recommended models for Yaskawa inverters The main recommended models for Yaskawa inverters

Yaskawa inverter is mainly used in the following series: Low-pressure type V1000: Amazing! A small inverter is controlled using a simple real current vector J1000: High reliability from a compact inverter! Simple operation, simple setting Varispeed ...

How to adjust the multi-stage speed of Yaskawa V1000 inverter? How to adjust the multi-stage speed of Yaskawa V1000 inverter?

Yaskawa Inverter A1000 User Guide 1. Description of the operator: (1). Keyboard description: 【ESC】Function: 1. Return to the previous screen; 2. Shift the bit that needs to be changed when setting the parameter number to the left; 3. If you press and hold it, you can ...

Yaskawa servo motor - the selection step of servo control Yaskawa servo motor - the selection step of servo control

1. Determine mechanical specifications, load, rigidity and other parameters; 2. Confirm the action parameters, stroke, accuracy, acceleration and deceleration time, cycle, moving speed, etc.; 3. Select motor inertia, load inertia, motor axis conversion inertia, and rotor inertia; 4. Select the motor back ...

Performance characteristics of Yaskawa servo motors Performance characteristics of Yaskawa servo motors

Superior performance "I hope to run the machine at a faster speed and with higher precision" ----∑-V. series servo, the performance of which is the best in the industry. It has the highest amplifier responsiveness in the industry, which greatly shortens the setting time It is only 1/12 of our conventional products ...

What is the reason for Yaskawa servo alarm AF5? What is the reason for Yaskawa servo alarm AF5?

1. When the control power supply is put in, it is caused by the failure of the servo unit circuit board, and the servo unit needs to be replaced. 2. When it occurs in servo ON, then it is caused by the failure of the servo unit circuit board or the short-term motor power line, and the servo unit or motor needs to be replaced.

How to choose a Yaskawa inverter model How to choose a Yaskawa inverter model

1. Specifications and parameters of the motor The inverter drives the motor during use, so the inverter can be selected from the perspective of the motor to select the model and specification. First of all, we must first understand the specifications and parameters of the motor. You can use Yaskawa inverter ...

Yaskawa Robotics – How does the Robot Perception System work? Yaskawa Robotics – How does the Robot Perception System work?

The robot perception system transforms various internal state information and environmental information of the robot from signals to data and information that can be understood and applied by the robot itself or between robots, in addition to the need to perceive mechanical quantities related to its own working state, such as displacement, velocity, acceleration, force and force.

Yaskawa inverter - what are the application fields of low-voltage inverter? Yaskawa inverter - what are the application fields of low-voltage inverter?

1. Fan With the continuous development of industry, the application of fans is becoming more and more extensive, especially in the chemical, stone and textile industries. However, there is a general problem of over-air volume in the design of the fan, and throttling is generally used when the air volume needs to be adjusted, that is, the damper is adjusted.

What are the fault codes of Yaskawa inverter What are the fault codes of Yaskawa inverter

The fault codes of Yaskawa inverters are as follows: OC overcurrent; PG wiring is disconnected or wiring is incorrect; GF output ground fault ground short circuit ; PUF fuse blowing fuse blowing ; OV Main circuit overvoltage Main circuit overvoltage ...

Yaskawa CH700 inverter innovatively integrates anti-sway control technology Yaskawa CH700 inverter innovatively integrates anti-sway control technology

When the crane is working, the start and stop of the cart and trolley mechanism, as well as the acceleration and deceleration process, will cause the suspended load to swing, which not only reduces the production efficiency but also brings great safety hazards to the staff and related equipment. And Yaskawa Electric has been deeply involved in ...

Yaskawa servo drive fault code and handling method Yaskawa servo drive fault code and handling method

1. If the fault code on the Yaskawa servo drive is UV1, it means that the low voltage of the main circuit is lower than the low voltage standard of 200V, at this time, we need to check whether there is a problem with the wiring of the power supply; 2. If the ...

How to wire Yaskawa servo motor B1B2? How to wire Yaskawa servo motor B1B2?

1. First of all, connect the terminal block of Yaskawa servo B1B2, in which the B1 terminal receives the power supply and the B2 terminal receives the signal; 2. Then, connect the terminal block of Yaskawa servo B1B2, wherein B1 terminal receives power supply, and B2 terminal receives signal; 3. After the wiring is completed, ...

Yaskawa Robot - the basic function of the robot control system Yaskawa Robot - the basic function of the robot control system

(1) Memory function: store operation sequence, motion path, motion mode, motion speed and information related to production process; (2) Teaching function: offline programming, online teaching, indirect teaching. There are two types of online teaching: teaching box and guided teaching; (3) With ...

Advantages of Yaskawa inverter A1000 Advantages of Yaskawa inverter A1000

Excellent motor drive function Advanced motor drive skills All motors can be controlled – whether they are driving induction motors or synchronous motors (IPM motors/SPM motors) – with high utility current vectoring. Inverters for induction and synchronous motors ...

Yaskawa servo drive alarm 810 reset method Yaskawa servo drive alarm 810 reset method

1. Check the reason for alarm 810: Alarm 810 is caused by the temperature inside the controller is too high, which may be caused by the heat inside the controller is too high or the power supply voltage is unstable. 2. Check the heat dissipation of the controller: check whether the radiator of the controller is blocked, ...

Yaskawa servo motor - ten common faults and troubleshooting methods of servo motors Yaskawa servo motor - ten common faults and troubleshooting methods of servo motors

1. Motor encoder alarm 1. The cause of the failure (1) Wrong wiring; (2) electromagnetic interference; (3) Encoder hardware damage caused by mechanical vibration; (4) Pollution caused by the on-site environment; 2. Troubleshooting (1) Check the wiring and eliminate the error ...

Yaskawa Electric - how to match the reducer according to the servo motor in practical application Yaskawa Electric - how to match the reducer according to the servo motor in practical application

1: Flange specification The cross-sectional size of the reducer is generally about the same as the cross-sectional size of the motor, and other parameters refer to the description of the selected brand, and the technical sample is generally marked with the selection steps and calculation examples. The specific model is indicated differently by brand. Usually in the output flange size or cross-sectional size ...

Yaskawa robot origin lost Yaskawa robot origin lost

There are two scenarios in which the origin of the Yaskawa robot is lost: A. Loss of the origin of individual shafts; B. Lose all axis origins. All axes are created at the same time: When the combination of the robot and the control cabinet is changed, all axes are registered at the origin position at the same time. Each axis is created separately: change the motor or ...

Yaskawa H1000 inverter overload oL2 fault Yaskawa H1000 inverter overload oL2 fault

There are two types of inverter overload faults: 1. If there is a problem with the load, it is a problem with the motor, such as the lack of oil in the bearing, the damage to the bearing, the burning of the winding, etc., and there is a situation that the power of the motor is small, and it is more difficult to drag the load. 2. It is the inverter ...

Midea's holding of Kuka eventually led to Midea's Yaskawa going the other way Midea's holding of Kuka eventually led to Midea's Yaskawa going the other way

Not long ago, it was found from the national enterprise information management system that the joint venture industrial manipulator enterprise founded by Midea and Yaskawa Electric announced the record cancellation/announcement information on April 12, and had already established a liquidation team to accept debt applications. The joint venture is a joint venture in Guangdong ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top