Differences between Siemens transmitters and Rosemount transmitters: Siemens' transmitters are piezoresistive pressure transmitters, while Rosemount's transmitters are capacitive pressure transmitters.
A transmitter is a converter that converts the output signal of a sensor into a signal source that can be recognized by the controller (or converts the non-electric power input from the sensor into an electrical signal and expands it for measurement and control from a distance). Together, the sensor and the transmitter form the monitoring signal source for automatic operation. Different physical quantities require different sensors and corresponding transmitters. There are many varieties of transmitters, and the transmitters used in industrial control instruments mainly include temperature transmitters, pressure transmitters, flow transmitters, current transmitters, voltage transmitters and so on.
Maintenance Functions:
1. Input overload maintenance;
2. Maintenance of output over-current constraint; Differences between Siemens transmitters and Rosemount transmitters: Siemens' transmitters are piezoresistive pressure transmitters, while Rosemount's transmitters are capacitive pressure transmitters.
A transmitter is a converter that converts the output signal of a sensor into a signal source that can be recognized by the controller (or converts the non-electric power input from the sensor into an electrical signal and expands it for measurement and control from a distance). Together, the sensor and the transmitter form the monitoring signal source for automatic operation. Different physical quantities require different sensors and corresponding transmitters. There are many varieties of transmitters, and the transmitters used in industrial control instruments mainly include temperature transmitters, pressure transmitters, flow transmitters, current transmitters, voltage transmitters and so on.
Maintenance Functions:
1. Input overload maintenance;
2. Maintenance of output over-current constraint;
3. Long-term short-circuit maintenance of output current;
4. Two-wire port transient induction lightning and inrush current TVS suppression maintenance;
5. Overvoltage limit maintenance of power supply≤ 35V;
6. Reverse connection maintenance of power supply.
|
More on that
|
Factors to consider when installing a Rosemount 644 temperature transmitter
Rosemount 644 temperature transmitter must be considered when installing the factors, only we solve these unfavorable factors, in the installation of the Rosemount temperature transmitter will not encounter some unnecessary things
routine
Electrical temperatures such as RTDs and thermocouples ...
|
|
How to care for your Rosemount pressure transmitter after use
Eight ways to use Rosemount pressure transmitters:
1. When measuring steam or other high-temperature media, it is necessary to connect a condenser such as a buffer tube (coil), and the working temperature of the Rosemount transmitter should not exceed the limit.
2. When wiring, pass the cable through the waterproof joint or wrap it around.
|
|
External factors influencing the failure of the Rosemount 3051 transmitter
1. The impulse tube is faulty
There are two simplest problems with the pressure duct of the Rosemount 3051 transmitter, which is blockage and leakage of the pressure duct. Once this problem is presented, the most obvious manifestation is that the leakage surface index of the impulse pipe will be abnormal.
|
|
How Rosemount pressure transmitters work
1. The working principle of Rosemount pressure transmitter
When the Rosemount pressure transmitter operates, the process pressure is transferred to the filling fluid by the isolation diaphragm and filling fluid on the high and low pressure sides, which in turn transfers the pressure to the sensing diaphragm in the center of the sensor. The sensing diaphragm is a tensioned ...
|
|
Features of Rosemount pressure transmitters:
The main features of Rosemount pressure transmitters are as follows:
1. It has the function of converting high and low pressure side:
The conversion function of the high and low voltage side of this sensor is mainly through the adjustment of the internal parameters of the handheld communicator, and the useful data on the high and low voltage side is realized.
|
|
Precautions for use of Rosemount differential pressure transmitters
Rosemount differential pressure transmitter in daily use we should pay attention to something, take Rosemount transmitter 3051DP differential pressure transmitter as an example, Rosemount differential pressure transmitter has a coplanar differential pressure transmitter and a flat mounted differential pressure transmitter in use The principle is the same, but the installation ...
|
|
How to maintain the Rosemount 3051 pressure transmitter
United States rosemount 3051 pressure transmitter maintenance is mainly divided into two points:
1. In the whole process of accurate measurement, some common faults often occur in the Rosemount pressure transmitter, and the immediate judgment and analysis and resolution of common faults are especially important for the production and manufacturing that has been carried out.
|
|
What are the main advantages of Rosemount temperature transmitters?
What are the main advantages of Rosemount temperature transmitters?
1. Only by adapting to harsh environments can it be strong
Rosemount temperature transmitters generally work in a wide range of environments, from extremely cold to extremely hot areas, many of which work in the open air.
|
|
A summary of methods for on-site inspection of Rosemount transmitter failures
When something goes wrong with the Rosemount transmitter, you can first use the common methods of on-site inspection to check it, such as: query method: recall the ignition, smoke, odor, power supply change, lightning strike, wetting, misoperation, and mismaintenance before the fault occurs; Intuitive method: investigate external damage to the circuit, leakage of the impulse pipe, ...
|
|
Rosemount differential pressure transmitter selection considerations
The following points should be considered in the selection of differential pressure transmitters:
1. Measure the scale, the accuracy of the demand and the measurement function;
2. Measure the environment of the outer surface, such as the industrial environment of petrochemical industry, the existence of flammable, toxic and explosive risk atmosphere, and the high ambient temperature;
3 tested ...
|
|
The Rosemount 3051 transmitter cannot be powered on
The Rosemount 3051 transmitter will not be powered on or may damage the transmitter after it is placed in the tripping device. When our technicians have understood these problems, they have analyzed and made corresponding countermeasures from three aspects, as follows:
Rosemont ...
|
|
What to do if the Rosemount pressure transmitter measurement is inaccurate
Common Rosemount pressure transmitter measurement incorrect situations:
1. The input impedance of the Rosemount transmitter load should be in line with RL≤ (transmitter supply voltage -12V)/(0.02A)Ω if necessary, if it does not match, corresponding measures can be adopted according to its differences: such as increasing the power supply ...
|
|
How to choose a Rosemount transmitter for standard accuracy
Not every Rosemount product is the same, for example, the 3051 pressure transmitter and the 3051S high-precision pressure transmitter are not in the same range. But there is also a big relationship between the two. For example, the 3051CD transmitter is now used in ...
|
|
Fault Judgment in Rosemount Differential Pressure Transmitter Applications
Fault judgment and analysis in the application
In the process of measuring the transmitter, there are often some problems, and the timely analysis and treatment of faults are crucial for the ongoing production According to the experience of daily maintenance, some of the analysis methods and analysis methods are summarized and summarized.
|
|
How to troubleshoot the Rosemount 3051 differential pressure transmitter if it encounters problems
1. Line failure
When the computer in the Rosemount transmitter monitoring system shows abnormal values, it is necessary to immediately check the line status of the junction box of the differential pressure transmitter to see if there is a short circuit, etc., and the way to check is to measure the resistance.
...
|
|
Key Features of the Rosemount 248 Temperature Transmitter:
Top mount and rail mount applications provide 2-year stability.
The integrated LCD meter provides easy indication of the process and diagnostic indications.
Available as a ready-to-install solution, including a wide range of sensors, thermowells, and housings.
Polished stainless steel housing can be applied to ...
|
|
How the Rosemount 3051 pressure transmitter works
The 3051 pressure transmitter is used to measure the level, density, and pressure of liquids, gases, or vapors, and then convert the pressure signal into a 4-20mADC signal output. There are mainly capacitive pressure transmitters and diffusion silicon pressure transmitters, ceramic pressure transmitters, strain gauge pressure transmitters, etc.
...
|
|
Rosemount transmitter pressure gauges are widely used
Rosemount transmitters are used in industrial process control and technical measurement processes, because the elastic and sensitive elements of mechanical pressure gauges have high mechanical strength and easy production, so that mechanical pressure gauges are more and more widely used.
Rosemont ...
|
|
An indispensable accessory for Rosemount transmitters
Before selecting a Rosemount transmitter, it is necessary to consider whether it is a threaded device or a flanged device, and the flanged device is divided into a single flange device and a double flange device. In order to let you better choose the flange, we have summarized some knowledge about the flange type:
Threading ...
|
|
How to choose the Rosemount 3051DP differential pressure transmitter
1.3051D transmitter is a coplanar pressure transmitter, which can measure the pressure or the side differential pressure, and there are two options P is the differential pressure measurement and G is the gauge pressure.
2. To understand the range used in the field, select the corresponding code according to the range, a total of 5 options: the lowest - 6.216KPA and the maximum 13789.54KPA.
...
|
|