What are the main advantages of Rosemount temperature transmitters?

1. Only by adapting to harsh environments can it be strong

Rosemount temperature transmitters generally work in a wide range of environments, from extremely cold to very hot areas, many of them work in the open air, to be able to resist flying sand, dust, but also to resist moisture, high resistance to salt corrosion, acid corrosion, anti-polluting gas interference, to adapt to the extreme cold, high temperature, strong vibration, impact and other conditions of normal work, but also to strong noise resistance, high signal-to-noise ratio.

2. The price is moderate, suitable for mass production

Rosemount temperature transmitters are consistent and suitable for automated mass production, and have high requirements for processing equipment to eliminate inconsistencies and errors caused by manual operations.

3. High stability and reliability

There are a lot of Rosemount temperature transmitters due to the use of environmental conditions need to use metal for packaging, so generally the selection of welding sealing, this kind of Rosemount temperature transmitter has sensitive components and integrated circuits inside, inert gas or vacuum isolation from the outside world, there are pressure resistance, air tightness requirements, as well as welding strength requirements and air leakage rate requirements, the welding quality requirements are also relatively high, and the welding process requires that the deformation is relatively small, can not form damage to internal components and microcircuits.

More on that
The Rosemount Twisted Square thermowell avoids wake shedding The Rosemount Twisted Square thermowell avoids wake shedding

When a problem arises in the design of Rosemount thermowells, it is necessary to analyze the cause of its failure, and then go further and propose solutions. In some less complicated cases, it may be necessary to make a small change, such as adding one millimeter without changing the predetermined measurement orientation ...

Rosemount transmitters feature two-way communication Rosemount transmitters feature two-way communication

The intelligent Rosemount transmitter is composed of a sensor and a microprocessor (microcomputer), which makes full use of the computing and storage capabilities of the microprocessor to process the data of the sensor, including the conditioning of the measurement signal (such as filtering, amplification, A/D conversion, etc.), data display, etc.

What to do if the Rosemount pressure transmitter measurement is inaccurate What to do if the Rosemount pressure transmitter measurement is inaccurate

Common Rosemount pressure transmitter measurement incorrect situations: 1. The input impedance of the Rosemount transmitter load should be in line with RL≤ (transmitter supply voltage -12V)/(0.02A)Ω if necessary, if it does not match, corresponding measures can be adopted according to its differences: such as increasing the power supply ...

Rosemount X-Well Wins Best Product Award in Sensor Category Rosemount X-Well Wins Best Product Award in Sensor Category

Shanghai, China (November 3, 2016) – Emerson's Rosemount X-Well Technology temperature measurement components won the Best of the Best Product Award in the Sensors category at the highly anticipated CONTROL ENGINEERING China 2016 annual competition. ...

Precautions for use of Rosemount differential pressure transmitters Precautions for use of Rosemount differential pressure transmitters

Rosemount differential pressure transmitter in daily use we should pay attention to something, take Rosemount transmitter 3051DP differential pressure transmitter as an example, Rosemount differential pressure transmitter has a coplanar differential pressure transmitter and a flat mounted differential pressure transmitter in use The principle is the same, but the installation ...

Problems to be noted when calibrating Rosemount transmitters Problems to be noted when calibrating Rosemount transmitters

1. After adjusting the zero point, use the standard pressure source to apply pressure slowly, and increase the pressure to the maximum scale, and the output value is about 20mA. 2. The verification regulations require that the two high and low pressure chambers of H and L are connected to the outside world, and observe that the zero position is not in the direction of 4mA.

Rosemount Models 2088, 2090F, and 2090P Pressure Transmitters Quick Installation Guide Rosemount Models 2088, 2090F, and 2090P Pressure Transmitters Quick Installation Guide

1.Rosemount 2088   Install it directly to the impulse pipe without the need for an additional mounting bracket, or use the optional mounting bracket to mount it directly to a wall, panel, or 2" pipe. 2. Rosemount 2090P Use of existing welded short casings ...

How the Rosemount transmitter is wired How the Rosemount transmitter is wired

During the use of the Rosemount transmitter, wire the Rosemount transmitter according to the following steps: 1. Take out the Rosemount 3051 and remove the electronic enclosure marked "FIELD TERMINALS". 2. Will be positive ...

Rosemount transmitter signal line grounding method Rosemount transmitter signal line grounding method

If the Rosemount transmitter does not have alarms and safety adjustment options installed, the transmitter will typically operate according to the default alarm settings, i.e., the alarm condition is set to "high" and the safety is set to "off". Then proceed as follows: 1. ...

Features of the Rosemount 8732E Electromagnetic Flowmeter: Features of the Rosemount 8732E Electromagnetic Flowmeter:

1. The measurement is not affected by the change of fluid density, viscosity, temperature, pressure and conductivity. 2. There are no obstruction moving parts in the measuring pipe, no pressure loss, and the requirements for the straight pipe section are low. There is a common adaptability to slurry measurement. 3. Reasonable selection of sensor lining and electrode materials, ...

How to troubleshoot the Rosemount 3051 differential pressure transmitter if it encounters problems How to troubleshoot the Rosemount 3051 differential pressure transmitter if it encounters problems

1. Line failure When the computer in the Rosemount transmitter monitoring system shows abnormal values, it is necessary to immediately check the line status of the junction box of the differential pressure transmitter to see if there is a short circuit, etc., and the way to check is to measure the resistance. ...

A method for verifying a current loop signal for a Rosemount pressure transmitter A method for verifying a current loop signal for a Rosemount pressure transmitter

The Rosemount pressure transmitter uses a 4-20mA signal, which is the conversion value of the output generated by the pressure transmitter. The output of the transmitter is detected according to the HART protocol, however, it is converted to a proportional current so that it can be visualized as a reading. Normally, at zero level output, the transmitter displays 4mA ...

The Rosemount 3051 transmitter cannot be powered on The Rosemount 3051 transmitter cannot be powered on

The Rosemount 3051 transmitter will not be powered on or may damage the transmitter after it is placed in the tripping device. When our technicians have understood these problems, they have analyzed and made corresponding countermeasures from three aspects, as follows: Rosemont ...

Installation of Rosemount transmitter attachments Installation of Rosemount transmitter attachments

The Rosemount transmitter is an important accessory in the use of time and time and time components, which will also affect the accuracy of the transmitter measurement results. Therefore, in order to prevent the occurrence of measurement errors, we need to pay attention to the following points in the equipment process of additional equipment.   1. Rosemont ...

The Rosemount 3051 transmitter has its own advantages The Rosemount 3051 transmitter has its own advantages

1. The five-year stable soil is 0.125%, which can greatly reduce the cost of verification and protection. 2. Faster dynamic response, which can reduce the variability of the process. 3. The co-plane planning can realize a comprehensive measurement scheme. 4. Compact and lightweight coplanar planning with the best function ...

Features and performance of Rosemount pressure sensors Features and performance of Rosemount pressure sensors

Features and performance of Rosemount pressure sensors 1. Diffusion silicon pressure sensor The working principle of the diffusion silicon pressure sensor is that the pressure of the measured medium acts directly on the diaphragm of the sensor (stainless steel or ceramic), so that the diaphragm produces a micro-displacement proportional to the pressure of the medium, ...

What causes inaccurate measurements in Rosemount pressure transmitters What causes inaccurate measurements in Rosemount pressure transmitters

Rosemount Pressure Transmitter Inaccurate Measurement Causes:   1. Whether the power supply of the Rosemount pressure transmitter is normal, if it is less than 12VDC, you should check whether there is a large load in the circuit, and the input impedance of the transmitter load should be in line with RL≤ (transmitter supply voltage -12V)/(0.02A...

Rosemount transmitters are affected by the angle of inclination of the installation Rosemount transmitters are affected by the angle of inclination of the installation

The actual working performance of the Rosemount transmitter will be affected by the angle of inclination, ambient temperature, static pressure and fluid temperature of the device.

The Rosemount 3051 transmitter is prone to some failures The Rosemount 3051 transmitter is prone to some failures

1. The pressure of the 3051 transmitter does not go up to the output of the transmitter, the output of the pressurized transmitter does not change, and the output of the pressure transmitter changes suddenly, and the zero position of the pressure relief transmitter cannot be returned. In this case, you should see if the pressure interface is leaking or blocked, and after looking at the wiring method and power supply, ...

How to solve the problem of Rosemount differential pressure transmitter migration failure How to solve the problem of Rosemount differential pressure transmitter migration failure

The migration of differential pressure transmitters is a form of application, which refers to the process of artificially moving the measuring point of a differential pressure transmitter from the zero point to the required value. The migration of differential pressure transmitters includes two major contents: positive migration and negative migration.

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top