Features of Rosemount pressure transmitters:

Create Date: 2024-8-30 12:03:23|Source: Rosemount/Rosemount

The main features of Rosemount pressure transmitters are as follows:
Features of Rosemount pressure transmitters:
  1. It has the function of converting high and low pressure side:

The conversion function of the high and low voltage side of this sensor is mainly through the adjustment of the internal parameters of the handheld communicator, and the useful data conversion of the high and low voltage side can be realized, even if it is reconfigured after conversion, it can also ensure that the overall condition is normal, and it can also save manpower and material resources.

2. Wide range scale and large range ratio:

The inductive characteristics of the intelligent Rosemount pressure transmitter include the characteristics of the large scale of the range and the large range ratio, in which the range ratio is mainly the ratio of its maximum measurement scale and the minimum measurement scale, the intelligent pressure transmitter is related to the conventional imitation transmitter, its most outstanding advantage is that it can effectively reduce the inventory, and can also be adjusted freely according to the relevant process needs, without changing the table, and do not need to worry about the overrun of the range.

3. Easy to protect and manage:

The intelligent Rosemount pressure transmitter uses a handheld communicator and intelligent transmitter communication, and can choose to wire the terminal position and terminal of the field transmitter, which can ensure the safety of the appearance maintenance staff, invent a safer working environment, and ensure that the control room can reasonably adjust the transmitter implementation range, which is convenient for equipment protection and management.

More on that
The difference between a Rosemount transmitter and a Siemens transmitter The difference between a Rosemount transmitter and a Siemens transmitter

The difference between Siemens' transmitter and Rosemount's transmitter: Siemens' transmitter is a piezoresistive pressure transmitter, and Rosemount's transmitter is a capacitive pressure transmitter. The transmitter converts the output signal of the sensor into a signal that can be recognized by the controller.

The meaning of the Rosemount transmitter fault code indication The meaning of the Rosemount transmitter fault code indication

Press Limit: The process variable read out by the transmitter is not within the transmitter range, which means that the range of the set volume exceeds the range of the transmitter cassette, and the solution is to replace the transmitter cassette.   Temp Limit: ...

How to troubleshoot the Rosemount 3051 differential pressure transmitter if it encounters problems How to troubleshoot the Rosemount 3051 differential pressure transmitter if it encounters problems

1. Line failure When the computer in the Rosemount transmitter monitoring system shows abnormal values, it is necessary to immediately check the line status of the junction box of the differential pressure transmitter to see if there is a short circuit, etc., and the way to check is to measure the resistance. ...

Precautions for use of Rosemount differential pressure transmitters Precautions for use of Rosemount differential pressure transmitters

Rosemount differential pressure transmitter in daily use we should pay attention to something, take Rosemount transmitter 3051DP differential pressure transmitter as an example, Rosemount differential pressure transmitter has a coplanar differential pressure transmitter and a flat mounted differential pressure transmitter in use The principle is the same, but the installation ...

How to choose a Rosemount transmitter for standard accuracy How to choose a Rosemount transmitter for standard accuracy

Not every Rosemount product is the same, for example, the 3051 pressure transmitter and the 3051S high-precision pressure transmitter are not in the same range. But there is also a big relationship between the two. For example, the 3051CD transmitter is now used in ...

How the Rosemount 3051 pressure transmitter works How the Rosemount 3051 pressure transmitter works

The 3051 pressure transmitter is used to measure the level, density, and pressure of liquids, gases, or vapors, and then convert the pressure signal into a 4-20mADC signal output. There are mainly capacitive pressure transmitters and diffusion silicon pressure transmitters, ceramic pressure transmitters, strain gauge pressure transmitters, etc.    ...

Features that Rosemount Instrument Thermowells have Features that Rosemount Instrument Thermowells have

Rosemount Instrument Heat Jacket has the following features:   1. Similar tags – when presenting some similar applications that only need to be changed slightly, it should be possible to imitate the application value of a specific tag, and then there is no need to re-enter the repetitive information, only change the variables that need to be changed in the new use.

Rosemount transmitter installation requirements and how to install it Rosemount transmitter installation requirements and how to install it

Rosemount transmitters must be installed in a constant temperature environment, which is also determined by the characteristics of the flange transmitter. Because the measured medium of ordinary transmitters generally enters the transmitter measurement chamber through the impulse tube. If the measurement is a viscous liquid medium, it will be easier to form a conductive ...

What is the difference between a Siemens transmitter and a Rosemount transmitter What is the difference between a Siemens transmitter and a Rosemount transmitter

Differences between Siemens transmitters and Rosemount transmitters: Siemens' transmitters are piezoresistive pressure transmitters, while Rosemount's transmitters are capacitive pressure transmitters. The transmitter converts the output signal of the sensor into other signals that can be recognized by the controller.

Problems encountered during the use of the Rosemount 3051 transmitter Problems encountered during the use of the Rosemount 3051 transmitter

1. What kind of output signal does the Rosemount transmitter need to get: mV, V, mA and frequency output digital output, and the choice of what kind of output depends on a variety of factors, including the separation between the Rosemount transmitter and the system controller or display, whether there is "noise" or other electronic interference signals.

What to look out for before using a Rosemount transmitter What to look out for before using a Rosemount transmitter

Rosemount transmitters can be used in many different fields, and different people face different situations and problems when using transmitters. Then the editor will introduce these problems to us.   How to clear the Rosemount transmitter ...

The Rosemount 3051 transmitter meter shows what the cause of the FAIL fault is The Rosemount 3051 transmitter meter shows what the cause of the FAIL fault is

1. Look at whether the diaphragm is damaged, if not, after removing it, press it with chopsticks after imitating the power on in the room to see if there is a pressure display, if there is a display change, you can only disassemble another one, see if the transmitter module is broken, because the transmitter modules are integrated ...

How the Rosemount 3051TG pressure transmitter works How the Rosemount 3051TG pressure transmitter works

The Rosemount 3051TG pressure transmitter is one of the most commonly used products in the Rosemount 3051 pressure transmitter that has been tested in the power industry for 40 years. Planning with high reliability, transient stability, and easy protection. Rosemount pressure transmitters are designed from planning to installation, from protection to operation.

What to do if the Rosemount pressure transmitter measurement is inaccurate What to do if the Rosemount pressure transmitter measurement is inaccurate

Common Rosemount pressure transmitter measurement incorrect situations: 1. The input impedance of the Rosemount transmitter load should be in line with RL≤ (transmitter supply voltage -12V)/(0.02A)Ω if necessary, if it does not match, corresponding measures can be adopted according to its differences: such as increasing the power supply ...

Factors to consider for Rosemount 5300 Series Radar Level Gauge Interface Measurements Factors to consider for Rosemount 5300 Series Radar Level Gauge Interface Measurements

For applications where the waveguide is completely submerged in liquids, the Rosemount 5301 measurement interface can be used, but the following guidelines should be followed 1. The dielectric constant of the above product must be known and cannot be changed. The Radar Master software has built-in dielectric constant calculations ...

Problems to be noted when calibrating Rosemount transmitters Problems to be noted when calibrating Rosemount transmitters

1. After adjusting the zero point, use the standard pressure source to apply pressure slowly, and increase the pressure to the maximum scale, and the output value is about 20mA. 2. The verification regulations require that the two high and low pressure chambers of H and L are connected to the outside world, and observe that the zero position is not in the direction of 4mA.

Rosemount X-Well Wins Best Product Award in Sensor Category Rosemount X-Well Wins Best Product Award in Sensor Category

Shanghai, China (November 3, 2016) – Emerson's Rosemount X-Well Technology temperature measurement components won the Best of the Best Product Award in the Sensors category at the highly anticipated CONTROL ENGINEERING China 2016 annual competition. ...

How to solve the problem that the Rosemount transmitter cannot be powered on How to solve the problem that the Rosemount transmitter cannot be powered on

Analysis and countermeasures when the Rosemount transmitter cannot be powered on. 1. There is something wrong with the leakage circuit breaker itself When the jump bar indicator and power indicator are not on, it is necessary to check whether the fuse is blown; Whether transformers, voltage regulator manifolds, and power switches ...

Installation requirements for Rosemount transmitter impulse tubing Installation requirements for Rosemount transmitter impulse tubing

The effect of the pressure impulse pipe is to transmit the pressure of the process medium to the transmitter to measure, in order to obtain accurate measurement values for the process measurement. There are many details that need to be paid attention to at the time of the installation, and the following summarizes the Luo ...

Rosemount Pressure Transmitter Measurement Principle Rosemount Pressure Transmitter Measurement Principle

The Rosemount pressure transmitter measurement principle progresses as follows: 1. The pressure transmitter transmits the pressure on the high and low pressure sides to the movable (sensing) diaphragm in the center of the sensor through silicone oil. 2. The movable diaphragm undergoes a slight displacement under the effect of differential pressure, so that the movable (sensing) membrane ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top