What problems are easy to encounter in the use of PT100 temperature sensor probes?
1. Is the output signal unstable?
A: Maybe it's the temperature instability of the temperature source itself, or the problem of on-site disturbance.
2. Is there a big error in the output of the transmitter?
Answer: There are many reasons for this situation, perhaps the resistance wire of the selected temperature sensor is not right, and the error is large, or the sensor is not set at the factory, and it can be returned for replacement.
3. Does the output of the transmitter not change when the temperature of the measured medium rises or falls?
Answer: This situation is mostly the problem of sealing the temperature sensor, perhaps the temperature sensor is not sealed well or the sensor is welded with a small hole during welding, this situation generally needs to replace the sensor shell to solve.
|
More on that
|
RKC converters – what are the functions of converters?
1. Power conversion: convert the voltage (rated 100V) and current (rated 5A or 1A) of the transformer into voltage (several volts) to meet the requirements of weak current components.
2. Isolation: current, secondary side security, and work grounding are used to ensure the safety of people and equipment, while weak current ...
|
|
RRKC thermostats – about output and control performance
When using a temperature controller to control a heater, it is necessary to convert the control calculation results of the temperature controller into electricity and apply it to the heater. Electromagnetic relays, solid state relays or phase controllers are usually used for conversion. Depending on the conversion method, the output of the temperature controller is different ...
|
|
RKC level gauge - the fault and treatment method of float level gauge
Fault 1, the indication is abnormal
The float level gauge is not indicated properly and is a very common fault of the float level gauge. Usually there are the following manifestations:
Phenomenon 1: The float level gauge in the atmospheric pressure workshop has the largest indication.
Troubleshooting: The float was found to be ...
|
|
Specifications and models of RKC thermostats
CH102 (48×48×100mm)
CH402 (48×96×100mm)
CH902 (96×96×100mm)
1. RH400 size: 48*96, depth 60, about 250g
1. Thermocouples: K, J, R, S, B, E, N, T, W5RE/W6RE, PL‖, U, L
...
|
|
RK thermostat - the use and adjustment of temperature control instruments
1. Set temperature: Press the SET button to set or check the temperature set point. Press the SET button at the beginning of the digital tube character flashing, indicating that the appearance has entered the setting state, press the △ key to add the set value, press the v key to decrease the setting value, press and hold the △ key or √ key The data will change rapidly, press the SET key again ...
|
|
RHK thermostat - the use of electronic thermostat and its classification introduction
First, the use of electronic temperature controller
The electronic temperature controller (resistive type) is measured by the method of resistance temperature sensing, and generally uses platinum wire, copper wire, tungsten wire and semiconductor (thermistor, etc.) as the temperature measurement resistor, and these resistors have their own advantages and points. Home Air Conditioner ...
|
|
Analysis of common fault causes of RKC temperature controller
1. The power indication is normal, but the temperature controller has no screen display. Most of this fault is caused by the heating of the voltage regulator element (7805 or 7812) on the thermostat during long-term use, which causes the solder joint to show a breakpoint, and sometimes it is caused by the phenomenon of virtual soldering at the factory.
2. Temperature controller ...
|
|
RRKC thermostats – how are temperature controllers wired and commissioned?
1. Take out the room temperature controller, and then connect the power supply terminal of the temperature controller to the power supply according to the terminal diagram of the temperature control chart
2. Then take out the temperature sensor that comes with the temperature controller and detect it
3. According to the temperature controller terminal, the temperature sensor is connected to the controller's transmission.
|
|
RKC converter – the design essentials of the power converter
In the design of power converter, firstly, the circuit topology is determined according to the load requirements, and the composition and backup mode of the power converter are determined, and the main parameters of the power converter are input voltage range, output voltage accuracy, load stability, voltage stability, output ripple, efficiency and dynamic.
|
|
What are the precautions for the installation of the RKG thermostat?
1) For RTD input, 3 wires with low resistance and no difference should be used.
2) The input signal line should be far away from the power line of the instrument. Power supply and load lines to prevent noise disturbances.
3) The power cord of the instrument is generally disturbed by the power supply.
4) Instrument complement ...
|
|
Specifications and models of RLC thermostats
CH102 (48×48×100mm)
CH402 (48×96×100mm)
CH902 (96×96×100mm)
1. RH400 size: 48*96, depth 60, about 250g
1. Thermocouples: K, J, R, S, B, E, N, T, W5RE/W6RE, PL‖, U, L
...
|
|
RKC Level Gauge – Installation of a pontoon level gauge
When transporting and unpacking, it is necessary to avoid excessive shock and vibration;
The installation should be firm and reliable, and the pontoon should be installed vertically to prevent the pontoon from colliding with the interior wall of the pontoon;
When the pontoon is hooked, it should not swing or pull and compress sharply, so as not to damage the sensor and reduce the accuracy of the instrument;
...
|
|
Key features of the RLC thermostat:
Thermocouples, RTDs, analog and other signals are freely inputted, and the range can be set freely;
The software zeros the full degree, the cold end measures the temperature separately, the amplifier is self-stabilizing, and the display accuracy is better than 0.5%FS;
Fuzzy theory combined with traditional PD method, fast and stable control, advanced tuning ...
|
|
Parameter setting operation of RLC temperature control table CH402
Model: CH402FS01-8*HN (for PECVD temperature control)
1) Single press SET: SV can be set (set temperature manually)
2) Press and hold the SET button for 2 seconds, ALI=1000 (absolute alarm temperature setting) and then press the SET button, ATU=1 (self-defining, self-interpreting a set of PID parameters) to exit ...
|
|
The debugging method of the temperature controller
Generally, there are three buttons to provide the need for setting, one is the Set button, press it once to enter the setting state. The other two offer upward and downward temperature adjustments, which can be adjusted to any temperature point. After adjusting to the desired temperature point, press the Set button again to confirm.
1. Turn on the smart thermostat ...
|
|
RKC thermostat - introduction of three wiring methods of thermal resistance
1. The three wiring methods of Pt100 RTD are different in principle:
The two-wire system and the three-wire system are measured by the bridge method, and the relationship between the temperature value and the analog output value is given after ***. There is no bridge on the four wires, it is completely just sent with a constant current source, measured by a voltmeter, and the test is given after *** ...
|
|
What are the common devices for RKC thermostats – digital displays?
In a variety of electronic control equipment, digital display has become an indispensable and important link. The electronic devices and corresponding driving circuits used for digital display are called digital displays.
Commonly used digital displays include glow digital tube displays, fluorescent digital tube displays, projection ...
|
|
RRKC Thermostat – Questions and Precautions About Thermostat Expansion Modules
1. Under what circumstances should I use a thermostat to expand the module?
The gradual development of the heating field is now very well recognized, and more and more users have begun to install electric heating, of course, when installing electric heating for users, they have also encountered some headaches.
For example, a large area ...
|
|
RK Level Gauge - Introduction to the characteristics of float level gauge
It is suitable for measuring the level and interface of the liquid medium in the container. In addition to on-site instructions, it can also be equipped with remote transmitters, alarm switches, and detection functions.
The indication is novel, the reading is intuitive, eye-catching, and the direction of the observation indicator can be changed according to the user's needs.
Large measuring range ...
|
|
The main technical specifications of the RKG thermostat
Input: all kinds of thermocouple (TC), RTD standard current and voltage signals (see input type table);
Basic error: 0.5% of the input full-scale ±±1 word;
Resolution: 1°C, 0.1°C;
Sampling period: 3 times/sec
Alarm function: ...
|
|