The reason why the inverter controls the motor – Reynolds

Create Date: 2024-8-30 12:03:23|Source: RENLE/RENOLDS

Q1: Why should I use VFD to control the motor?

When it comes to this issue, let's take a brief look at these two devices. The motor is an inductive load that hinders the change of current, and when it is started, a large change in current is generated. VFD, which is actually composed of a rectifier inverter circuit, turns the motor's power supply into a power supply with adjustable frequency.

In order to reduce the starting current of the motor, especially the high-power motor, the higher the power, the greater the starting current, which will bring a greater burden to the power supply and distribution network, and VFD can solve this starting problem, so that the motor can start smoothly and will not form excessive starting current.

Another feature of using VFD is to speed up the motor. In many occasions, it is necessary to control the speed of the motor to obtain better production power, and VFD speed regulation is always its biggest highlight. The VFD can be used to control the motor speed by changing the frequency of the power supply.

                               The reason why the inverter controls the motor – Reynolds

Q2: How does the VFD control the motor?

The wiring of the VFD control motor is relatively simple, similar to the wiring of the contactor. Three mains power supplies are connected to the motor, which is then connected to the motor. However, the VFD operating mode is also set differently.

First of all, let's take a look at the VFD terminal. Although there are many brands and different wiring methods, most of the terminals of VFDs are not much different. Generally, it is divided into positive and negative switch inputs, which are used to control the positive and negative starts of the motor. The reaction terminal is used to reflect the operation status of the motor, including the operating frequency, speed, fault condition, etc. Given the speed control, some VFDs use potentiometers, and some directly use buttons, all of which are impassable.

The above method is controlled by physical wiring, and the other method is through the communication network. Many VFDs now support communication control. You can control the start and stop of the motor, forward and reverse rotation, speed adjustment, etc. Through this communication line, the reaction information is also transmitted through communication.

Q3: What are the advantages of VFD control motors?

The advantages of the VFD control motor are also mentioned above. Here's a summary.

First, the start is stable, and the suspension is stable. The full-voltage direct start will directly produce an instantaneous current of seven or eight times the rated current, and the VFD controls the starting voltage and frequency of the motor, so that the motor starts from 0 little by little, and this starting time and abort time can be set. From the abort condition to the set speed, it is possible to start or abort the motor at a stable speed at a fixed time.

Second, the speed is adjustable. Speed regulation is also one of the reasons for using VFD. In the production process, we will adjust the motor speed according to the power requirements, and VFD will adjust the motor speed by changing the frequency.

More on that
Reynolds inverter FAQ - parameter class Reynolds inverter FAQ - parameter class

1. What are the factory parameters of inverter rehabilitation? N600 = 100 (often press the WR button for 3-5 seconds), it is necessary to be in the shutdown state to be effective. 2. In the parameters of the N308 motor of the inverter, [motor leakage inductance reactance] is the specified sub...

The difference between inverter motor and ordinary motor – Reynolds The difference between inverter motor and ordinary motor – Reynolds

Inverter motor - used for special occasions with inverter, it is different from the general motor in that a strong cooling fan is added. And the power of the fan comes from the independent power supply, can not be from the main motor out of the line, the effect of the strong cooling fan is to ensure that the motor at low speed...

Inverter replacement component requirements - Reynolds Inverter replacement component requirements - Reynolds

1) Find out the basic parameters and appearance of the equipment that needs to be replaced. The basic parameters include the rated operating current, the capacitance of the capacitor, the resistance value of the resistor, the value of the GTR Darlington device (current amplification factor), the switching characteristics and saturation voltage of the IGBT (including IPM) device, etc.

The difference between "braking" and "parking" of the inverter - Reynolds The difference between "braking" and "parking" of the inverter - Reynolds

There are two types of inverter parking. One form is called "free parking". As the name suggests, it is to quickly "power off" the motor, so that the motor can slide and park by its own inertial force (OFF2 parking); The other form is called "brake parking". So this "brake parking ...

Reynolds frequency converters are remotely controlled for wiring Reynolds frequency converters are remotely controlled for wiring

1. Connect X (switching input) drive terminal to control the inverter start-stop/positive rotation; 2. Connect to the AI (analog input) terminal to control the frequency of the inverter (perhaps made into PID closed-loop control automatic adjustment frequency) ​ 3. ...

Reynolds inverter code function description Reynolds inverter code function description

F09 second acceleration time 0.10 - 999.9sec; 5.0sec; △** The acceleration and deceleration parameters and the second acceleration and deceleration parameters are switched by terminal X3 (see F55); F10 second deceleration time 0.10 - 999.9sec; 5.0sec; △**Acceleration and deceleration parameters and the second acceleration and deceleration parameters are switched ...

The reason for using frequency conversion speed regulation - Reynolds The reason for using frequency conversion speed regulation - Reynolds

Variable frequency speed regulation can be used in most motor drag occasions, because it can provide accurate speed control, so it can easily control the rise, descent and variable speed operation of mechanical transmission. The use of frequency conversion can greatly improve the efficiency of the process (the variable speed does not depend on the mechanical part) and at the same time ...

General Purpose Inverter Repair Inspection – Reynolds General Purpose Inverter Repair Inspection – Reynolds

The first step is to check whether the appearance of the inverter is defective, including whether the indicator light is in normal operation, whether the mission control function of the operation panel is complete, and carefully observe the appearance of the inverter under the operating condition, and do the corresponding recording operation; When repairing the inverter, check whether the voltage value and current value exceed the ...

The lightning protection method of Reynolds inverter The lightning protection method of Reynolds inverter

The lightning protection measures of the inverter equipment are another important peripheral measure to ensure the safe operation of the inverter, especially in the area where lightning is active or in the lively season, this problem is particularly important. Today's inverter products are generally equipped with lightning ...

Two Reynolds technologies were included in the "2020 Water Conservancy Technology Key Promotion Catalogue" Two Reynolds technologies were included in the "2020 Water Conservancy Technology Key Promotion Catalogue"

In May 2020, Reynolds was recommended by relevant departments to apply for the Ministry of Water Resources's "2020 Key Promotion and Guidance Catalogue of Advanced and Practical Water Conservancy Technologies".

Safety precautions for low-voltage soft lift - Reynolds Safety precautions for low-voltage soft lift - Reynolds

Precautions for low-voltage soft starters For cooling purposes, the soft starter must be installed in a straight direction. In order to ensure excellent heat dissipation, there should be room for the soft starter device. Main circuit selection ...

Inverter speed regulation method - Reynolds Inverter speed regulation method - Reynolds

1. Pole change logarithmic speed regulation method This speed regulation method is to change the number of stator poles of the cage motor by changing the connection method of the stator winding, so as to reach the intention of speed regulation; The wiring is simple, the control is convenient, and the price is low; It can be used in conjunction with pressure and speed regulation, electromagnetic slip clutch to obtain high efficiency ...

Renault is available in a variety of product ranges Renault is available in a variety of product ranges

JJR1000系列:   JJR1011;JJR1017;JJR1022;JJR1030;JJR1037;JJR1045;JJR1055;JJR1075;JJR1090;JJR1115;JJR1132;JJR1160;JJR1200;JJR1250;JJR1320;JJR1400;JJR1500;JJR1600 ...

Protection function of the Reynolds soft starter Protection function of the Reynolds soft starter

1. Overload protection function: The soft starter introduces a current control loop, so that the change of motor current can be tracked and detected at any time. By increasing the setting of overload current and the anti-time control mode, the overload protection function is realized, so that when the motor is overloaded, the thyristor is turned off and an alarm signal is issued. ...

Wiring of the main circuit of the inverter - Reynolds Wiring of the main circuit of the inverter - Reynolds

(1) Inverter three-phase communication input terminal (R, S, T) The power input terminal is connected to the three-phase communication power supply through the circuit breaker of the circuit breaker for line protection, regardless of the connection phase sequence. It should be noted here that the three-phase communication power supply must not be directly connected to the inverter output ...

Reynolds soft starter features: Reynolds soft starter features:

The Reynolds soft engine is a new type of software launcher that can assist users in quickly launching and closing the computer system. It was developed by Reynolds and its main function is to provide a fast, safe and reliable software launcher that can assist users in quickly launching and closing ...

Reynolds EPS emergency power supply routine maintenance Reynolds EPS emergency power supply routine maintenance

1. EPS the first use of the emergency power supply, the battery pack should be charged continuously for 48 hours after discharging protection; 2. EPS emergency power supply to keep the whole machine dry, clean, free of dust and foreign objects, wipe with a soft cloth after shutting down, and strictly ...

Precautions for Wiring Reynolds Inverters Precautions for Wiring Reynolds Inverters

1. The inverter itself has a strong electromagnetic disturbance, which will disturb the work of some equipment, so we can add a cable sleeve to the output cable of the inverter. 2. The control line in the inverter or control cabinet is at least 100mm away from the power cable, etc. ...

Misunderstanding of inverter control loop wiring - Reynolds Misunderstanding of inverter control loop wiring - Reynolds

1. The wires of the inverter control circuit should be strictly distinguished from the main circuit cable (power line) and placed separately. This effectively prevents the inverter's control circuit from being disturbed by harmonics in the inverter's main circuit. 2. To separate the connection of the inverter from the terminals or contacts of other control circuits, ...

Overheating failure light on start-up analysis - Reynolds Overheating failure light on start-up analysis - Reynolds

(1) Frequent starting, resulting in excessive temperature, causing overheating maintenance of soft starter. (The number of starts of the soft starter should be controlled to no more than 6 times per hour, especially for heavy loads) (2) During starting, ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top