Inverter replacement component requirements - Reynolds

Create Date: 2024-8-30 12:03:23|Source: RENLE/RENOLDS

1) Find out the basic parameters and appearance of the equipment that needs to be replaced. The basic parameters include the rated operating current, the capacitance of the capacitor, the resistance value of the resistor, the value of the GTR Darlington device (current amplification factor), the switching characteristics of the IGBT (including IPM) device, and the saturation voltage. The shape requirements include the external scale, terminal position and device method, etc., and then replace the required equipment according to the same requirements.

                               Inverter replacement component requirements - Reynolds

2) All connectors should be recorded or marked when disassembled to avoid misplacement during replacement or rehabilitation.

3) The contact surface between the power equipment and the radiator should be evenly coated with thermal grease and fastened with screws.

* In most cases, the machine is in operation, and when the machine is not running, the inverter needs to be properly kept.

* In most cases, the machine is in operation, and when the machine is not running, the inverter needs to be properly kept.

1) Storage

The room should be dry, no direct sunlight, no corrosive gas, and no dust; The relative humidity is 20%-90% and there is no frost; The temperature is between -10 and 30 °C (if the temperature is about 40 °C, the storage period should not exceed 6 months; About 50°C, the storage period does not exceed 3 months).

2) Maintenance

If there is no need to add leakage for a long time, the withstand voltage decreases, that is, the deterioration is accelerated (the higher the temperature, the faster the deterioration), therefore, at least once a year, the external power supply is added, so that the correction power-on time is 30-60min, the characteristic is that only the inverter monomer is energized (do not have to be connected to the motor), and the input end of the Shanghai Yaobang inverter can be connected to the power supply.

More on that
Reynolds-5G empowers the paper industry to improve quality and efficiency of the industrial IoT control system Reynolds-5G empowers the paper industry to improve quality and efficiency of the industrial IoT control system

From September 23rd to September 25th, 2020, the 2020 China International Paper Technology Exhibition was held in Hall D1 of Suzhou International Expo Center.

Inverter: The right inverter to use - Reynolds Inverter: The right inverter to use - Reynolds

Low pressure issues The VFD reports a low voltage issue when the drive's DC link voltage drops below 62% of the nominal level at the high setting (480 Vac) and 50% of the nominal value at the low setting (400 Vac). The +10% and -15% voltage tolerances in most manuals are the ones that claim to be ...

Replacement of spare parts for frequency converters – Reynolds Replacement of spare parts for frequency converters – Reynolds

In order for a VFD to operate reliably for a long time, it is necessary to repair the electronic components in the VFD on a regular basis and replace the primary components of the VFD according to the service life. 1. Cooling fan The VFD power module is the most heat-generating device, and its ...

The internal structure of the inverter is the role of Reynolds The internal structure of the inverter is the role of Reynolds

The inverter is mainly composed of rectifier (AC to DC), filtering, inverter (DC to communication), braking unit, drive unit, detection unit and microprocessor unit. The inverter adjusts the voltage and frequency of the output power supply by the internal IGBT break, and ...

Inverter control loop wiring taboo - Reynolds Inverter control loop wiring taboo - Reynolds

1. The wires laid out in the inverter control circuit should be separated from the main circuit cable (power line), so as to avoid the harmonic disturbance components on the side of the main circuit of the inverter from polluting the inverter control circuit; 2. Due to the faulty signal of the inverter and ...

Reynolds soft starter fault code and fault handling Reynolds soft starter fault code and fault handling

Reynolds soft starter fault code Instantaneous stop -F 01 Instantaneous stop terminal 7 to terminal 10 open TOO LONG STARTING TIME -F 02 STARTING TIME IS TOO LOW AND THE STARTING TIME IS TOO LONG (GREATER THAN 60S) Overheating -F 03 Start too often, reduce the number of starts Input out of phase -F 04 ...

Two Reynolds technologies were included in the "2020 Water Conservancy Technology Key Promotion Catalogue" Two Reynolds technologies were included in the "2020 Water Conservancy Technology Key Promotion Catalogue"

In May 2020, Reynolds was recommended by relevant departments to apply for the Ministry of Water Resources's "2020 Key Promotion and Guidance Catalogue of Advanced and Practical Water Conservancy Technologies".

Lightning protection measures for Reynolds frequency converters Lightning protection measures for Reynolds frequency converters

The lightning protection measures of the inverter equipment are another important peripheral measure to ensure the safe operation of the inverter, especially in the area where lightning is active or in the lively season, this problem is particularly important. Today's inverter products are generally equipped with mines.

The structure of the low-voltage circuit breaker - Reynolds The structure of the low-voltage circuit breaker - Reynolds

Low-voltage air circuit breaker, also known as active air switch or air switch, belongs to the switch electrical appliance, is used when the circuit is overloaded, short circuit and undervoltage can actively break the circuit of the electrical appliances, can also be used as infrequent start of the motor or opening and closing circuit, low-voltage air circuit breaker has an all-round circuit breaker ...

How to measure a frequency converter with a multimeter – Reynolds How to measure a frequency converter with a multimeter – Reynolds

How to use a multimeter to measure the quality of the inverter, it needs to be noted that for personal safety, it is necessary to ensure that the machine is powered off, and remove the inverter input power line R, S, T and output line U, V, W before operation! First of all, the multimeter is hit to the "secondary pipe" file, and then through the multimeter ...

Parameter setting of acceleration and deceleration time of Reynolds universal inverter Parameter setting of acceleration and deceleration time of Reynolds universal inverter

The acceleration time of the Reynolds inverter is the time required for the output frequency to rise from 0 to the high frequency, and the deceleration time is the time required to decrease from the high frequency to 0. Generally, the frequency converter uses the frequency setting signal to rise and fall to confirm the acceleration and deceleration time. The rise of the frequency setting must be limited when the motor accelerates.

The way to set the parameters of the inverter - Reynolds The way to set the parameters of the inverter - Reynolds

There are many setting parameters of the inverter, and each parameter has a certain range of choice, and the inverter can not work normally due to the improper setting of a single parameter in use, therefore, the relevant parameters must be set correctly. ...

The inverter has no short-circuit protection for the reason – Reynolds The inverter has no short-circuit protection for the reason – Reynolds

Short-circuit maintenance is a function of equipment connected between the power supply and the load, which can effectively disconnect the short-circuit point from the power supply when the load side is short-circuited. If an equipment has a short-circuit maintenance function, it must have a certain short-circuit breaking ability; And a device with the ability to break in a short circuit ...

Inverter speed regulation method - Reynolds Inverter speed regulation method - Reynolds

1. Pole change logarithmic speed regulation method This speed regulation method is to change the number of stator poles of the cage motor by changing the connection method of the stator winding, so as to reach the intention of speed regulation; The wiring is simple, the control is convenient, and the price is low; It can be used in conjunction with pressure and speed regulation, electromagnetic slip clutch to obtain high efficiency ...

Inverter leakage solution - Reynolds Inverter leakage solution - Reynolds

1. The cause of the leakage problem Some sites use frequency converters to control the motor, which will present the problem of leakage, and the leakage voltage ranges from tens of volts to 200 volts. In view of this problem, the reasons for this shortcoming are theoretically expounded and stated as follows. Depend on...

Parameter setting of acceleration and deceleration time of Reynolds universal inverter Parameter setting of acceleration and deceleration time of Reynolds universal inverter

The acceleration time of the Reynolds inverter is the time required for the output frequency to rise from 0 to the high frequency, and the deceleration time is the time required to drop from the high frequency to 0. Usually, the inverter uses the frequency setting signal to rise and fall to confirm the acceleration and deceleration time. When the motor accelerates, the rise of the frequency setting must be constrained ...

Inverter maintenance and undervoltage fault handling - Reynolds Inverter maintenance and undervoltage fault handling - Reynolds

In the repair of the inverter, we often hear about overpressure problems, but underpressure problems are also common problems encountered in the use of inverters. The reason is that the main circuit voltage is lower than the lower limit caused by the maintenance action or the damage of a rectifier bridge or the instantaneous power failure of the power grid, and the input is flat. Inverter after-sales ...

Water pump inverter pressure adjustment method - Reynolds Water pump inverter pressure adjustment method - Reynolds

Water pump inverter pressure conditioning steps: 1. Open PID closed-loop control; 2. Close the pressure circuit; 3. Set the pressure feedback and set the given pressure; When the pump speed is changed, the outlet pressure can be changed. Adjust the operating frequency of the VFD. The higher the frequency, the higher the pump speed and the higher the pressure. About ...

PLC and inverter communication mode PLC and inverter communication mode

1. The switching signal of PLC controls the inverter The PLC can control the start, stop and reset of the inverter through the program; It can also control different combinations of high-speed, medium-speed and low-speed terminals of the inverter to achieve multi-stage speed operation. However, because it is controlled by switching ...

AC servo motor with inverter control method - Reynolds AC servo motor with inverter control method - Reynolds

Because the inverter and servo are different in performance and function, and the use is not very different, it is not possible: 1) In the case of speed control and torque control, the general frequency converter is not very high, and there are also frequency converters that are used to react signals in the upper position to form a closed loop.

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top