Precautions for Wiring Reynolds Inverters

Create Date: 2024-8-30 12:03:23|Source: RENLE/RENOLDS

1. The inverter itself has a strong electromagnetic disturbance, which will disturb the work of some equipment, so we can add a cable sleeve to the output cable of the inverter.

2. The control line in the inverter or control cabinet is at least 100mm away from the power cable, etc.

                            Precautions for Wiring Reynolds Inverters

3. When buying an inverter, there will be an inverter clarification book. If not, you can download it from the website of the brand you purchased. The contents of the inverter clarification book are appropriately detailed, including product introduction, working principle, device commissioning, etc.

4. Correct wiring and parameter setting, read the manual before installing the inverter, and set the parameters correctly according to the use.

5. Pay attention to the relationship between speed and head, the inverter runs below 5HZ, and the motor heats up.

More on that
Tips for using reducers - Reynolds Tips for using reducers - Reynolds

1. After 200-300 hours of operation, the first oil change should be carried out, and the quality of the oil should be checked regularly in the subsequent use, and the oil mixed with impurities or deteriorated oil must be replaced in time. Under normal circumstances, the reducer for long-term continuous operation should be replaced after 5000 hours of operation or once a year.

Fault analysis of short circuit of inverter motor – Reynolds Fault analysis of short circuit of inverter motor – Reynolds

According to the different degrees of short circuit, the inverter can display the short circuit of the SCF1 motor; SCF2 has an impedance short circuit; SCF3 is short-circuited to ground. Causes of the problem: insulation problems with the cable from the motor or inverter to the motor; current transformer fault; ...

Inverter breakdown factor – Reynolds Inverter breakdown factor – Reynolds

1. Overpressure leads to brake pipe breakdown. The so-called overvoltage of the inverter refers to the fact that the inverter voltage composed of various reasons exceeds the additional voltage, which is reflected in the DC voltage of the inverter DC bus. Overvoltage alarm generally appears when the machine is shut down, and its main ...

The reason for using frequency conversion speed regulation - Reynolds The reason for using frequency conversion speed regulation - Reynolds

Variable frequency speed regulation can be used in most motor drag occasions, because it can provide accurate speed control, so it can easily control the rise, descent and variable speed operation of mechanical transmission. The use of frequency conversion can greatly improve the efficiency of the process (the variable speed does not depend on the mechanical part) and at the same time ...

Inverter control method - Reynolds Inverter control method - Reynolds

The output voltage of low-voltage general frequency conversion is 380-650V, the output power is 0.75-400kW, and the operating frequency is 0-400Hz. Its control methods have gone through the following four generations. 1U/f=C Sinusoidal Pulse Width Modulation (SPWM) Manipulation MethodIts Characteristics ...

The distance between the Reynolds frequency converter and the motor determines the cable and wiring method The distance between the Reynolds frequency converter and the motor determines the cable and wiring method

1. The interval between the inverter and the motor should be as short as possible. This reduces the cable's capacitance to ground and reduces the source of disturbance. 2. The control cable is shielded cable, the power cable is shielded cable or from the inverter to the motor.

PLC and inverter communication mode PLC and inverter communication mode

1. The switching signal of PLC controls the inverter The PLC can control the start, stop and reset of the inverter through the program; It can also control different combinations of high-speed, medium-speed and low-speed terminals of the inverter to achieve multi-stage speed operation. However, because it is controlled by switching ...

Classification and working principle of Reynolds inverter Classification and working principle of Reynolds inverter

Classification of Reynolds frequency converters: There are many classification methods for Reynolds inverters, which can be divided into voltage-type inverters and current-type inverters according to the classification of the main circuit operation method; According to the classification of switching methods, it can be divided into PAM operation.

The abnormal installation of the inverter in the power frequency motor leads to hazards The abnormal installation of the inverter in the power frequency motor leads to hazards

Installing a variable-frequency drive (VFD) on the power frequency motor can complete the precise control and speed regulation of the motor, and improve the power and accuracy of the progressive motor. However, if it is not properly used and used, the following damages may occur: ...

Classification of Reynolds inverter types Classification of Reynolds inverter types

1. Classified according to the input voltage level According to the input voltage level, the inverter can be divided into low-voltage inverter and high-voltage inverter, and the low-voltage inverter is common in China with single-phase 220 V inverter, three-phase 220 V inverter, and i-phase 380 V inverter. High-voltage inverters are commonly used in 6 kV, 10 kV transformers.

Operating procedures for Reynolds frequency converters Operating procedures for Reynolds frequency converters

Bypass cabinet: The cabinet is equipped with high-voltage inlet and outlet isolation switches QS1 and QS2. Among them, QS1 is a single-pole single-throw variable frequency incoming knife switch, and QS2 is a single-pole double-throw power frequency and variable frequency outgoing knife switch. The bypass cabinet is a high-voltage environment, please investigate the status of the live display and electromagnetic lock to ensure safety before ...

How to determine the frequency of start-up – Reynolds How to determine the frequency of start-up – Reynolds

Generally, most motors start to speed up from 0Hz, but in some special cases, it is necessary to start directly from a certain frequency. At this time, the frequency output of the VFD at the moment of activation is the activation frequency. In general, you need to set the activation frequency in the following situations. ...

Reynolds universal inverter start-up mode Reynolds universal inverter start-up mode

1. Direct launch The universal inverter insists on starting at the beginning of the time according to the set starting frequency and starting frequency, and then accelerates to a given frequency according to the selected acceleration time Second, the speed of the tracking start Universal inverter ...

The item that needs to be maintained after the inverter is shut down – Reynolds The item that needs to be maintained after the inverter is shut down – Reynolds

1. Use a vacuum cleaner with a plastic nozzle to thoroughly clean the inside and outside of the inverter cabinet to ensure that there is no excessive dust around the equipment. 2. Check the ventilation and lighting of the frequency conversion room, and the ventilation equipment can operate normally. 3. Check the inverter ...

The main failure mode of mechanical parts – Reynolds The main failure mode of mechanical parts – Reynolds

The top failure modes of mechanical parts: Failure: The mechanical part cannot complete its normal function within the planning and booking period and under the regular conditions. Ways in which mechanical parts fail: overall cracking, plastic deformation, corrosion, abrasion, gluing, and touch exhaustion General ...

Introduction to the function of the inverter - Reynolds inverter Introduction to the function of the inverter - Reynolds inverter

In power distribution equipment such as voltage distribution cabinets and switchgear at all levels of power plants and substations, the conductors connected between large electrical equipment such as generators and transformers and various electrical equipment are called busbars. Busbars, also known as busbars, are used to collect, distribute, and transmit electrical energy. The connection methods of the bus bar are ...

Dust design considerations for frequency converters - Reynolds frequency converters Dust design considerations for frequency converters - Reynolds frequency converters

1) The air duct of the inverter cabinet should be planned reasonably, and the exhaust should be clear and smooth, so as to avoid the formation of vortex in the cabinet and the accumulation of dust in a fixed direction. 2) The top air outlet of the inverter cabinet should be equipped with a protective top cover to avoid debris from falling directly.

Advantages of the inverter vector control system - Reynolds Advantages of the inverter vector control system - Reynolds

Dynamic "fast response" DC motors are rectified constrained and excessively high di/dt is not allowed. The asynchronous motor is only constrained by the capacity of the inverter, and the multiple of the forced current can be very high, so the speed echoes quickly, generally reaching the millisecond level, which has surpassed the DC motor in terms of speed. At low frequencies ...

The external configuration of the inverter is solved - Reynolds The external configuration of the inverter is solved - Reynolds

With the improvement of the degree of automation of packaging machinery, packaging machine inverter (hereinafter referred to as VFD) plays an increasingly important role in packaging machinery. Capsule filling machine, high-speed tablet press, bottling production line, aluminum-plastic packaging machine, cartoning machine, each equipment will use VFD, mainly ...

The difference between inverter motor and ordinary motor - Reynolds The difference between inverter motor and ordinary motor - Reynolds

1. The heat dissipation system is different: Generally, the cooling fan in the fan is in the same line as the fan movement, while the two are separated in the inverter motor. Therefore, when the frequency conversion of the fan is too low, it may burn out due to overheating. 2. Frequency conversion ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top