1. EPS the first use of the emergency power supply, the battery pack should be charged continuously for 48 hours after discharging protection;
2. EPS emergency power supply to keep the whole machine dry and clean, free of dust and foreign objects, wipe with a soft cloth after shutting down, and it is strictly forbidden to clean the machine with corrosive detergents;
3. EPS emergency power supply regularly (according to the equipment maintenance cycle formulated by the customer) to check whether the terminal is loose, should keep the contact firm;
4. EPS emergency power supply is regularly discharged by artificial inverter once a quarter (it is recommended to be 2-3 months/time from the use period), and each discharge can be in 30min;
Do not start the (manual/mandatory) start switch of the 5. EPS emergency power supply in a non-emergency situation, even if you need to verify whether this function is normal during regular equipment inspection, it can be started for 10 minutes, and do not discharge for a long time; Make sure that the battery cannot be forced to discharge deeply;
6. EPS emergency power supply, check whether the load of each output circuit exceeds the rated maximum output power of the EPS emergency power supply, if the overload is not greater than the output circuit breaker does not jump and is not found in time, it may cause the EPS emergency power supply inverter inverter to start when the power failure;
7. Avoid EPS emergency power overload and work at full load, so that the system can work normally in the case of full load and overload of 120%, but working in the case of full load has a certain impact on the service life of important components such as battery pack and power devices, therefore, it is recommended that users try not to overload and run at full load for a long time, so as not to affect the service life of the machine.
|
More on that
|
Selection of large fan inverter in the factory - Reynolds
First, select from the inverter "software".
The reason why the factory chooses the inverter to work together with the fan is that it is hoped that the automation and intelligent design of the inverter technology can improve the speed regulation mode of the fan, and reduce the wasted energy consumption, which not only improves the wind efficiency.
|
|
Reynolds soft starter manual
Reynolds JJR5000 series all-digital intelligent AC motor soft starter adopts power electronics technology, microprocessor technology and modern control theory technology, and is a new type of starting equipment at the international advanced level. This product can effectively limit the starting current of asynchronous motor start-up, and is widely used in ...
|
|
Inverter frequency regulation fault solution - Reynolds
Most of the applications of frequency converters (hereinafter referred to as -VFDs) are primarily due to the fact that VFDs can change the output frequency and thus change the speed of the motor. If the frequency of the VFD cannot be adjusted and no damage is found on the hardware, it can be considered that the maximum output torque of the VFD is less than the load progress torque ...
|
|
Structural characteristics of Reynolds RHY series inverter governor
1. Technology: (PC or PLC) is used to make the equipment complete the intelligent constant pressure variable supply water supply according to the requirements of water supply and fire protection;
2. High efficiency and energy saving: the system can set the pressure according to the demand, and the system actively adjusts the speed of the pump and the number of pumps according to the set pressure, so that the equipment can run in ...
|
|
Precautions for the coordination of PLC and inverter - Reynolds
Under the current production conditions, when the inverter is used to form an automatic control system for control, in many cases, it is necessary to choose PLC and inverter to match the use, such as bearing cleaning, packaging paper printing, PCB board production, etc.
PLC ...
|
|
Water pump inverter pressure adjustment method - Reynolds
Water pump inverter pressure conditioning steps: 1. Open PID closed-loop control; 2. Close the pressure circuit; 3. Set the pressure feedback and set the given pressure; When the pump speed is changed, the outlet pressure can be changed. Adjust the operating frequency of the VFD. The higher the frequency, the higher the pump speed and the higher the pressure. About ...
|
|
Applications of Reynolds frequency converters
A frequency converter is a power electronic device that can change the frequency of an AC power source to control the speed and output power of a motor. Inverters are widely used in industry, aviation, metallurgy, petroleum, chemical industry, electric power and other fields.
|
|
Introduction to soft starters and their relationship with frequency converters - Reynolds
When the high-power motor starts, the current is large, which will cause the grid voltage to be seriously shaken, in order to deal with this problem, the general requirements for speed regulation are not high, and the soft engine can be used to reduce the voltage and start. However, the drop in the starting current when the step-down is started will also make the starting torque drop significantly.
|
|
Difference Between Soft Starter and Inverter – Reynolds
Soft starters and frequency converters are two completely different products. The inverter is used in the local area where speed regulation is required, and its output not only changes the voltage but also changes the frequency at the same time; A soft starter is actually a voltage regulator, which is used when starting a motor, and the output only changes the voltage and does not change the frequency. Change...
|
|
Inverter: The right inverter to use - Reynolds
Low pressure issues
The VFD reports a low voltage issue when the drive's DC link voltage drops below 62% of the nominal level at the high setting (480 Vac) and 50% of the nominal value at the low setting (400 Vac).
The +10% and -15% voltage tolerances in most manuals are the ones that claim to be ...
|
|
Reynolds product range models
JJR1000系列:
JJR1011;JJR1017;JJR1022;JJR1030;JJR1037;JJR1045;JJR1055;JJR1075;JJR1090;JJR1115;JJR1132;JJR1160;JJR1200;JJR1250;JJR1 ...
|
|
Reynolds drives use the most energy-efficient method
As an electronic electric, the inverter itself also consumes electricity (about 3-5% of the additional power). A 1.5 hp air conditioner consumes 20-30W of electricity, which is equivalent to the length of a lamp. The inverter works under the power frequency and has the function of saving electricity, which is practical.
But the conditions are:
At the top of the list, great success ...
|
|
Reynolds inverter FAQ - parameter class
1. What are the factory parameters of inverter rehabilitation?
N600 = 100 (often press the WR button for 3-5 seconds), it is necessary to be in the shutdown state to be effective.
2. In the parameters of the N308 motor of the inverter, [motor leakage inductance reactance] is the specified sub...
|
|
Reynolds inverter manual
Reynolds inverter brochure (partial)
Before installing
When unpacking, it is found that the machine has water or left water traces, indicating that the inverter has been flooded, so please do not install and use it.
When unpacking, it is found that the machine is damaged and deformed or the parts are missing, please do not install and use it, otherwise there will be fault expansion and personnel ...
|
|
What inverter to choose what occasion - Reynolds
We need to ensure that the capacity of the inverter is matched. First of all, according to the nature of the load, the correct selection of the type of inverter.
When selecting the inverter, the current value of the actual motor should be used as the basis for the selection of the inverter, and the rated power of the motor can only be used as a ...
|
|
Introduction and features of Reynolds soft starters
Reynolds soft starters include soft starters for high, medium and low voltage motors, including JJR1000 series, JJR2000 series, JJR5000 series, and RNB3000 series frequency converters. Reducing the starting power supply avoids voltage drops and voltage dips in the power supply. Smooth start-up avoids product damage. ...
|
|
Dust design considerations for frequency converters - Reynolds frequency converters
1) The air duct of the inverter cabinet should be planned reasonably, and the exhaust should be clear and smooth, so as to avoid the formation of vortex in the cabinet and the accumulation of dust in a fixed direction.
2) The top air outlet of the inverter cabinet should be equipped with a protective top cover to avoid debris from falling directly.
|
|
How to determine the frequency of start-up – Reynolds
Generally, most motors start to speed up from 0Hz, but in some special cases, it is necessary to start directly from a certain frequency. At this time, the frequency output of the VFD at the moment of activation is the activation frequency. In general, you need to set the activation frequency in the following situations.
...
|
|
Reynolds inverter power selection
The system power is equal to the product of the power of a general-purpose inverter and the power of the motor. As long as both work efficiently, the system power will be higher. From the perspective of power, when choosing VFD power, you should pay attention to the following points:
VFD ...
|
|
Small fan inverter choice - Reynolds
Now many electrical appliances are advocating the use of small parts, because small parts will not occupy space, and small parts can be moved and overhauled at any time, and the inverter also has a small inverter, how to buy a small fan inverter?
Power picking
...
|
|