The inverter selects the appropriate peripheral equipment - LS power generation

Create Date: 2024-8-30 12:03:23|Source: LS/Power Generation

After we have selected a suitable Variable-frequency Drive (VFD), we also need to consider whether we need to equip other peripheral equipment according to the actual situation of the site. The peripheral equipment selected by VFD mainly includes circuit breakers, reactors, contactors, braking resistors, etc.

                               The inverter selects the appropriate peripheral equipment - LS power generation

1. Circuit breaker

This circuit breaker can conveniently control the power off and closing of the circuit. It is mainly used to actively block the power supply when the frequency conversion system presents reverse current, overcurrent, short circuit and undervoltage, so as to have a blocking effect and maintain the power supply.

2. Electric disturbance equipment

Reactor is a common peripheral device in frequency conversion selection. When the VFD is too far away from the motor or the VFD is too close to the power supply, in order to improve the power factor and minimize the inrush current at the input end, it is necessary to add a DC reactor or AC reactor when selecting the VFD.

3. Current contactor

Contactors are divided into input contactors and output contactors. When a part of the frequency conversion system fails, it will actively block the power supply to prevent the equipment from burning out from a distance.

4. Braking resistance

When VFD is applied to inertial loads such as CNC machine tools and elevators, the selection of VFD requires the use of braking resistors to dissipate the excess energy generated in the frequency conversion system.

More on that
Inverter load test run step - LS power generation Inverter load test run step - LS power generation

1. Manually operate the work stop button of the inverter panel, investigate the work stop process of the motor and the display window of the inverter to see if there is any abnormal phenomenon. 2. If the inverter presents an overcurrent maintenance action during the process of starting P to abort the motor, ...

Principle of electrical equipment maintenance - LS power generation Principle of electrical equipment maintenance - LS power generation

1. Speak before you start When it comes to faulty electrical equipment, you should not rush into action, but ask about the passage and phenomenon of the fault. For unfamiliar equipment, you should also understand the circuit principle and structural characteristics, and follow the corresponding rules. Before dismantling, it is necessary to fully understand each ...

Fatal failure of LS power terminal block Fatal failure of LS power terminal block

From the point of view of application, the function that should be reached is: it is necessary to conduct the local area where the touch part should be conducted, and the touch is reliable. If the insulating part should not be conducted, it is necessary to insulate it firmly. There are three common fatal problems in terminal blocks: ...

Quickly locate the fault method of switching power supply - LS power generation Quickly locate the fault method of switching power supply - LS power generation

Due to the short circuit of the load, the failure of the self-oscillation circuit and the loss of control of the protection circuit, the switching power supply will cause the base of the switch tube to be unable to get the switching pulse and intermittent operation, which makes it difficult to locate the shortcomings of SMPS. The difficulty of the repair operation and the improper method will expand the shortcomings, constituting the phenomenon of continuous burning of the switch pipe, etc., ...

Types of PLCs that produce electricity Types of PLCs that produce electricity

There are many categories of PLC, and the following is a brief introduction to PLC and its main functions   As an innovative PLC product family that combines the technical capabilities of power production and production, XGT is a system based on open networks, ultra-high-speed processing speeds, compact size and a large number of improved software.

Dealing with intermittent shutdown fault measures - power generation Dealing with intermittent shutdown fault measures - power generation

Because the touch of the network adapter is not good, perhaps due to disturbance and other problems, the DP network that has been used for a long time may show a "transient disconnection" situation, that is, it will be disconnected by an occasional moment, and it will soon recover normally. If OB86 is not downloaded, the CPU will stop during a transient outage. Now all over the option to download a ...

Summer maintenance and maintenance of inverter method - LS power generation Summer maintenance and maintenance of inverter method - LS power generation

1. Check the running status of the inverter, whether the voltage and current value during operation are within the normal range. 2. Carefully monitor and record the ambient temperature of the frequency conversion chamber, which is generally between -5 °C and 40 °C. The temperature rise of the phase-shifting transformer should not exceed 130°C. 3. Prevent ...

LS power production contactor application LS power production contactor application

LS touchers are divided into AC touchers (voltage AC) and DC touchers (voltage DC), which are used in electricity, power distribution and consumption. Toucher broadly refers to the electrical appliances that use the current flowing through the coil to generate a magnetic field in industrial electricity, so that the contacts are closed, so as to control the load. ...

Inverter external potentiometer connection method - LS power generation Inverter external potentiometer connection method - LS power generation

The two wires are connected to the resistor, and the other wire is connected to the adjustment terminal. The red thread is attached to the blackhead and inserted in a small hole. Connect both ends of the IR potentiometer to +10V and ACM, and slide the termination to the voltage input terminal AVI. ...

Energy-saving method of ventilator inverter - LS power generation Energy-saving method of ventilator inverter - LS power generation

high-power Although some inverters are fan type inverters, but it is a low-power fan inverter, such an inverter does not have the effect of energy saving, and it is necessary to achieve energy saving must be a high-power inverter, in addition to the high-power fan inverter, it is necessary to meet its ...

Grounding of the secondary side of the voltage transformer and the current transformer - power generation Grounding of the secondary side of the voltage transformer and the current transformer - power generation

1. The transformer is grounded twice It refers to the grounding of the S2 terminal of the current transformer or the ground of the n terminal of the voltage transformer. As long as the single point is grounded, because the transformer is blocked between the second and the first, before grounding, the secondary winding has no potential connection with the ground, after grounding, the transformer ...

Inverter circuit board repair and drawing-free maintenance method - LS power generation Inverter circuit board repair and drawing-free maintenance method - LS power generation

1. Be "confident" It is necessary to fully understand the principles of some typical circuits and be familiar with them. Guangzhou Kewo Training Center believes that drawings are dead, and the thoughts in the head are alive, able to make analogies, able to reason, and able to touch analogies. For example, switching power supply is always inseparable from ...

The difference between servo drive and frequency converter - LS produces electricity The difference between servo drive and frequency converter - LS produces electricity

Servo drives and frequency converters are defined differently The driver, also known as servo manipulator and servo amplifier, is a kind of manipulator used to control servo motors, and its function is similar to that of a frequency converter acting on a general communication motor. It is part of the servo system, mainly used for high-precision positioning ...

The difference between multi-function inverter and general-purpose inverter - LS produces electricity The difference between multi-function inverter and general-purpose inverter - LS produces electricity

With the deepening of factory automation, the high efficiency and low cost of active warehouses, elevators, transfer systems, etc., as well as the high speed, high efficiency and high precision of small CNC machine tools, kneading and forming machines, textile and film machinery, etc.

The difference between inverter and power saver - LS produces electricity The difference between inverter and power saver - LS produces electricity

First, the frequency conversion skill is only one of the many power-saving skills, including voltage regulation and current limiting, power factor compensation, phased power regulation, frequency conversion, chopping, filtering, energy feedback and other skills, even if the power saver using the principle of frequency conversion is concerned, the frequency converter is only power-saving.

Servo drives and servo motors – LS produces electricity Servo drives and servo motors – LS produces electricity

Driver: Under the premise of carrying out frequency conversion skills, the servo drive has carried out more advanced control skills and algorithm operations than general frequency conversion in the current ring, speed ring and azimuth ring inside the drive (the frequency converter does not have this ring), and it is much stronger than the traditional servo in terms of function.

Precautions for the use of inverter - LS produces electricity Precautions for the use of inverter - LS produces electricity

1. The inverter should not be installed on the equipment with vibration, because the main circuit connection screw in the inverter is simply loose, and many inverters are damaged due to this reason. Second, the wiring problem: the inverter input termination on an air initial maintenance current value can not be too large, ...

Inverter carrier frequency adjustment method - LS power generation Inverter carrier frequency adjustment method - LS power generation

A. The output voltage of the SPWM inverter is a series of pulses, and the pulse frequency is equal to the carrier frequency. B. In the current of the motor, there is a harmonic component with a strong carrier frequency, which will cause the vibration of the motor core and announce the noise. If the frequency of the noise is the same as that of the motor core.

LS Electric's motion control system solution on pillow (horizontal) packaging machine LS Electric's motion control system solution on pillow (horizontal) packaging machine

The pillow packaging machine mainly performs the operation of product forming, positioning, packaging and sealing, etc., and the equipment is composed of the packaging film shaft that provides the packaging film, the feeding shaft that provides the material, the cutter shaft that performs the sealing and cutting operation and the discharging shaft after the product packaging is completed, and the equipment structure diagram is as follows: ...

LS power production contactors are used in this area LS power production contactors are used in this area

LS contactors are divided into AC contactors (voltage AC) and DC contactors (voltage DC), which are used in electricity, power distribution and consumption. Contactor in a broad sense refers to the electrical appliances that use the current flowing through the coil to generate a magnetic field and close the contact to control the load in industrial electricity. ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top