Dealing with intermittent shutdown fault measures - power generation

Create Date: 2024-8-30 12:03:23|Source: LS/Power Generation

Because the touch of the network adapter is not good, perhaps due to disturbance and other problems, the DP network that has been used for a long time may show a "transient disconnection" situation, that is, it will be disconnected by an occasional moment, and it will soon recover normally. If OB86 is not downloaded, the CPU will stop during a transient outage. Now it is common to download an empty OB86 to deal with the downtime caused by the intermittent break.

                                 Dealing with intermittent shutdown fault measures - power generation

However, there are risks associated with this, and if it is not a flash outage, but a real network failure or slave failure, it can have catastrophic consequences if it is not down. For this reason, the following measures can be used to determine whether it is a flash break or a persistent slave fault.

1) In OB86, identify which network and which slave are faulty. If it is an "entry thing" (fault presentation), the M azimuth position for exclusive use of the slave will be used. If the fault of the slave is "something to leave" (the fault disappears), the M-bit for the slave is reset.

2) In OB1, start the 200ms punctuality with this M bit, and call SFC 46 (STP) when the punctuality time is up, causing the CPU to stop. If there is a transient break (the moment when M is 1 is less than 200ms), the punctuality of the timer is aborted and there is no shutdown.

3) Use one word to record the number of calls to OB86 and use HMI to display the number of calls to OB86.

If the faults of intermittent interruptions are frequent, the hardware must be dealt with, such as replacing the DP adapter, dealing with grounding, shielding, equipotential connection, anti-turbulence, etc.
More on that
The power frequency motor is abnormally installed with an inverter - LS produces electricity The power frequency motor is abnormally installed with an inverter - LS produces electricity

Installing a variable-frequency drive (VFD) on the power frequency motor can complete the accurate control and speed regulation of the motor, and improve the power and accuracy of the forward motor. However, if not properly equipped and used, it may cause the following hazards: ​ ...

LS Electric's motion control system solution on pillow (horizontal) packaging machine LS Electric's motion control system solution on pillow (horizontal) packaging machine

The pillow packaging machine mainly performs the operation of product forming, positioning, packaging and sealing, etc., and the equipment is composed of the packaging film shaft that provides the packaging film, the feeding shaft that provides the material, the cutter shaft that performs the sealing and cutting operation and the discharging shaft after the product packaging is completed, and the equipment structure diagram is as follows: ...

Introduction to vector control of inverter and motor - LS power generation Introduction to vector control of inverter and motor - LS power generation

As for the use of vector-operated motors, it can be divided into two categories, namely non-reactive vector control (SVC) and reactive vector control (FVC). Vectorless Handling (SVC): Due to the speed response, additional equipment for the encoder is installed in the motor dragged by the inverter, which is cumbersome. Here...

Methods for extending the service life of inverters - LS generates electricity Methods for extending the service life of inverters - LS generates electricity

1. The influence of electromagnetic disturbance on the inverter: In the modern industrial control system, the microcomputer or PLC control technology is mostly selected, and in the process of system planning or transformation, it is necessary to pay attention to the disturbance of the inverter to the microcomputer control board. The inverter is disturbed by the outside world, because the user ...

Switching analysis and synchronous control of inverter - LS power generation Switching analysis and synchronous control of inverter - LS power generation

AC asynchronous motors are widely used in all walks of life, and frequency converters and power frequency power supplies are often required to switch in the selection of frequency conversion speed control system. The primary types of switching are: fault switching and multi-machine system switching. In the process of operation of many production machinery, the motor is not allowed to stop ...

Motor & Electrical Control Technology Tips - LS Electricity Production Motor & Electrical Control Technology Tips - LS Electricity Production

1. Low-voltage electrical appliances: refers to electrical appliances that play the role of on-off, maintenance, control or regulation in circuits with a rated voltage of 1200V and a rated voltage of 1500V and below. 2. Main electrical appliances: electrical appliances used to send control instructions in the automatic control system. 3. Fuse: ...

Precautions for inverter installation tips - LS power generation Precautions for inverter installation tips - LS power generation

When the line power supply exceeds the driver's kV-A rating by 10 times, add a line reactor. A 3% impedance line reactor should be used to reduce power line transients caused by capacitor switching, line notching, DC bus overvoltage tripping, and inverter overcurrent and overvoltage conditions. Line...

LS power terminal is faulty LS power terminal is faulty

From the perspective of application, the function of the terminal block should be achieved: the contact part should be conducted, and the contact should be reliable. The insulating parts should not be conducted, and it is necessary to insulate them firmly. There are three common forms of fatal failure of terminal blocks: ...

What are the categories of PLC products? What are the categories of PLC products?

The XGT series is a creative PLC product family that combines LS's power generation technology capabilities to provide next-generation solutions based on open networks, ultra-high-speed processing speeds, compact scales, and greatly improved software for the engineering environment. XGT series for a variety of ...

Models and features of LS Metasol series products Models and features of LS Metasol series products

Metasol series MS (100A and below) products are newly launched and the primary product specifications: contactors, thermal relays, and center relays. Features: The body is small, the internal structure is sealed, and the safety factor is high ...

LS power production contactor application LS power production contactor application

LS touchers are divided into AC touchers (voltage AC) and DC touchers (voltage DC), which are used in electricity, power distribution and consumption. Toucher broadly refers to the electrical appliances that use the current flowing through the coil to generate a magnetic field in industrial electricity, so that the contacts are closed, so as to control the load. ...

Single-table driver for HLP2B Single-table driver for HLP2B

Principle of electrical equipment maintenance - LS power generation Principle of electrical equipment maintenance - LS power generation

1. Speak before you start When it comes to faulty electrical equipment, you should not rush into action, but ask about the passage and phenomenon of the fault. For unfamiliar equipment, you should also understand the circuit principle and structural characteristics, and follow the corresponding rules. Before dismantling, it is necessary to fully understand each ...

LS inverter classification LS inverter classification

LS Denden's low-voltage inverters provide optimal speed control in a variety of industrial sites, and are solutions that can demonstrate the completion of an automation system and have an epoch-making power saving effect. It includes four types of products: IGXA; S100; IS7; C100 series. ...

The reason for the overload trip of the inverter - LS generates electricity The reason for the overload trip of the inverter - LS generates electricity

1. The load is too heavy, the load carried by the motor is too heavy, or in other words, the resistance torque of the production machinery exceeds the additional torque of the motor. 2. Use improper overload, for example, increase the operating frequency of the inverter to the extra frequency of the motor, and the motor is in the extra frequency.

Inverter switching power supply circuit vein - LS power generation Inverter switching power supply circuit vein - LS power generation

1. Vibration circuit: the drainage-source and R4 of the main winding N1 and Q1 of the switching transformer are the channels for the working current of the power supply; R1 provides the starting current; The self-powered windings N2, D1, and C1 constitute the power supply voltage of the vibrating chip. The normal operation of these three links is the prerequisite for the power supply to vibrate.

LS power circuit breaker wiring method LS power circuit breaker wiring method

The wiring method of the circuit breaker has the front of the board, the back of the board, the plug-in type, the drawer type, if the user has no special requirements, they are supplied according to the front of the board, and the wiring before the board is a common wiring method. 1. Wiring method behind the board: The wiring feature behind the board is that the circuit breaker can be replaced or repaired, without wiring from the beginning.

The role of the inverter - LS generates electricity The role of the inverter - LS generates electricity

1. The inverter can adjust the power of the motor and complete the variable speed operation of the motor, so as to achieve the purpose of saving electricity. For example, it is reflected in the centrifugal fan and water pump, when the centrifugal fan and water pump use the frequency converter, the operator can convert the frequency to regulate the speed, and can easily control the flow rate according to the need, so as to save ...

Brake unit, brake resistor function - LS generates electricity Brake unit, brake resistor function - LS generates electricity

Brake unit: The function of the braking unit is to turn on the energy-dissipating circuit when the voltage Ud of the DC circuit exceeds the specified limit (such as 660V or 710V), so that the DC circuit can release energy by thermal energy after passing through the braking resistor. The braking unit can be divided into built-in and external, the former is ...

How to use the installation wiring of the LS inverter How to use the installation wiring of the LS inverter

1. Circuit wiring (1) The input (R, S, T) and output (U, V, W) of the inverter cannot be connected incorrectly; (2) Wire diameter selection (1) The wiring of the power supply and the inverter and the wire diameter selection method of the motor of the same capacity are the same; (2) The wiring between the inverter and the motor should consider the line electricity.

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top