The pillow packaging machine mainly performs the operation of product forming, positioning, packaging and sealing, etc., and the equipment is composed of the packaging film shaft that provides the packaging film, the feeding shaft that provides the material, the cutter shaft that performs the sealing and cutting operation and the discharging shaft after the product packaging is completed, and the equipment structure diagram is as follows:
LS Electric's new solution selects eXP+XMC+L7NH/S100+C series.
The XMC motion controller adopts EtherCAT communication protocol, which has functions such as azimuth synchronization control and cam control to complete multi-axis synchronous high-response control. Customized special function block, input the necessary parameters to complete the key process of equipment control.
The cutting shaft, feeding shaft and packaging film shaft complete high-speed and accurate positioning through the bus servo system; The discharge shaft uses a frequency converter to complete the synchronous discharge control.
The key points of the equipment control of the pillow packaging machine:
Complete the cutting knife, packaging film and feed cam curve active production
Complete the air defense package and anti-mis-cutting process
Completed the I-mark sensor compensation function
To this end, LS has introduced a dedicated utility block to complete high-speed and precise cutting movements.
This solution has the following advantages:
1. Special function blocks to complete customized services, time-saving and convenient;
2. Through the EtherCAT bus, improve work efficiency and reduce operation and maintenance costs;
3. The electronic cam curve is smooth, which effectively reduces the mechanical resonance;
4. The servo synchronization performance is good, and the stability of the system is effectively improved.
XMC series
LS is an EtherCAT-based stand-alone motion controller
High-Speed Program Processing: 6.25ns (Basic Instruction)
IEC verbal programming environment with G-code support
8-axis version, 16-axis version, 32-axis version, zui can support more than 64 axes
CAM electronic cam ズイ large support 32 tables
CAM electronic cam ズイ large support 32 tables
L7NH series
LS Electric's high-performance EtherCAT bus servo drive system
High-speed real-time performance, strong synchronization mechanism
Faster EtherCAT communication rate, 250μs smaller
Supports CoE, EoE and FoE
Supports a variety of encoder protocols
Optimized handling
|
More on that
|
LS power production contactor application
LS touchers are divided into AC touchers (voltage AC) and DC touchers (voltage DC), which are used in electricity, power distribution and consumption. Toucher broadly refers to the electrical appliances that use the current flowing through the coil to generate a magnetic field in industrial electricity, so that the contacts are closed, so as to control the load.
...
|
|
The difference between input reactor and output reactor – LS produces electricity
The rectifier part of the general inverter selects the diode uncontrollable bridge rectifier circuit, and the middle filter part selects the large capacitor as the filter, so the input current of the rectifier is actually the charging current of the capacitor, and the harmonic component is relatively steep and steep.
|
|
Precautions for the peripheral configuration of the inverter - LS generates electricity
(1) When the inverter is connected to the power grid of large-capacity power transformer (more than 500kVA), perhaps the same power transformer is connected with a thyristor converter without using a commutation reactor, or when there is a switching capacitor bank for power improvement in the same power grid, an AC reactor or DC reactor should be equipped.
|
|
The working principle of LS PLC module
When LS PLC is put into operation, its operation process is generally divided into three stages, namely input sampling, user program fulfillment and output rewriting. The completion of these three phases is called a scan cycle. Throughout the operation, the PLC's CPU repeatedly performs the performance at a certain scanning speed on ...
|
|
Whether the C-type circuit breaker is suitable for the motor circuit - power generation
Type C micro-break is used for general circuits, such as lighting circuits; D-type circuit breakers are used in power circuits such as electric motors, so can C-type micro-breakers be used in motor circuits?
Differences between C-type and D-type discontinuity:
C-type micro-disconnect: with ...
|
|
Types and characteristics of PLC digital output modules for power production
The main functions and functions of PLC:
1. For sequential control: sequential control is based on the current and pre-historical situation of the input switch, and produces the required switching output, so that the system can operate in a certain order. ...
|
|
Methods for extending the service life of inverters - LS generates electricity
1. The influence of electromagnetic disturbance on the inverter:
In the modern industrial control system, the microcomputer or PLC control technology is mostly selected, and in the process of system planning or transformation, it is necessary to pay attention to the disturbance of the inverter to the microcomputer control board. The inverter is disturbed by the outside world, because the user ...
|
|
The reason for the overload trip of the inverter - LS generates electricity
1. The load is too heavy, the load carried by the motor is too heavy, or in other words, the resistance torque of the production machinery exceeds the additional torque of the motor.
2. Use improper overload, for example, increase the operating frequency of the inverter to the extra frequency of the motor, and the motor is in the extra frequency.
|
|
Features of LS SUSOL series circuit breakers
Features of SUSOL series circuit breakers:
It can be used as the main switch of electrical equipment, and the limit breaking ability is high, Icu=Ics
Modular construction of circuit breakers: Tripper replacement (TS series) can be combined in a variety of combinations, such as ...
|
|
LS power production contactors are used in this area
LS contactors are divided into AC contactors (voltage AC) and DC contactors (voltage DC), which are used in electricity, power distribution and consumption. Contactor in a broad sense refers to the electrical appliances that use the current flowing through the coil to generate a magnetic field and close the contact to control the load in industrial electricity.
...
|
|
The difference between multi-function and general-purpose inverters
Multi-function inverters need to meet the following two conditions:
First, it can be driven by constant torque load, regardless of the type of machine, and can ensure continuous operation even if the load fluctuates greatly. If the above conditions are not satisfied, the inverter will be easy to stop, difficult to start again, and resistant to ...
|
|
Wiring of the main circuit of the inverter - LS generates electricity
1. The power supply should be connected to the R, S, and T terminals at the input end of the inverter, and must not be connected to the output terminal (U, V, W) of the inverter, otherwise the inverter will be damaged. After wiring, it is necessary to clean the trivial wires, which may cause abnormalities, failures and problems, and it is necessary to always keep ...
|
|
Introduction to the working principle of LS electric molded case circuit breaker
Molded case circuit breakers are also known as equipment circuit breakers, all parts are sealed in plastic housings, auxiliary contacts, undervoltage trippers and shunt trippers are modular. Because of the very compact structure, the molded case circuit breaker is basically impossible to maintain. It is mostly manually operated, and the large capacity ...
|
|
How to select servo motor - power production
Each type of servo motor has additional torque, maximum torque and servo motor inertia and other parameters in the standard items, each parameter and load torque and load inertia must have a relevant connection, the output torque of the servo motor should meet the requirements of the movement conditions of the load organization, such as the speed of the acceleration ...
|
|
How to select the inverter motor - LS produces electricity
Frequency conversion speed regulation motor is generally selected 4-level motor, the fundamental frequency operation point is designed at 50Hz, the frequency of 0-50Hz (speed 0-1480r/min) scale of the motor for constant torque operation, frequency 50-100Hz (speed 1480-2800r/min) scale of the motor for constant power operation, the entire speed regulation scale of (0 ...
|
|
Recommended models for power production contactors
GMC-6 Contactor GMC-6 Rated voltage: 110V/22OV/380V;
GMC-9 Contactor GMC-9 Rated voltage: 110V/22OV/380V;
GMC-12 Contactor GMC-12 Rated voltage: 110V/22OV/380V;
GMC-18 Contactor GMC-18 Rated voltage 110V/ ...
|
|
The role of the inverter - LS generates electricity
1. The inverter can adjust the power of the motor and complete the variable speed operation of the motor, so as to achieve the purpose of saving electricity. For example, it is reflected in the centrifugal fan and water pump, when the centrifugal fan and water pump use the frequency converter, the operator can convert the frequency to regulate the speed, and can easily control the flow rate according to the need, so as to save ...
|
|
Grounding of the secondary side of the voltage transformer and the current transformer - power generation
1. The transformer is grounded twice
It refers to the grounding of the S2 terminal of the current transformer or the ground of the n terminal of the voltage transformer. As long as the single point is grounded, because the transformer is blocked between the second and the first, before grounding, the secondary winding has no potential connection with the ground, after grounding, the transformer ...
|
|
The function and function of the inverter VFD - LS produces electricity
1. Energy saving
The energy-saving effect of VFD is mainly manifested in the application of fans and water pumps. After the fan and pump load is selected for frequency conversion speed regulation, the power saving rate is 20% - 60%, because the actual power consumption of the fan and pump load is basically proportional to the cubic speed. When users ask for an average ...
|
|
LS power inverter function
1. Soft up
The direct launch of the inverter motor has a serious impact on the power grid, and it will also have too high requirements for the capacity of the power grid, which is extremely unfavorable to the service life of equipment and power grid circuits. After the use of inverter to save energy, the use of inverter's speed regulation (V/F) function will make the starting current from a small ...
|
|