The difference between multi-function inverter and general-purpose inverter - LS produces electricity

Create Date: 2024-8-30 12:03:23|Source: LS/Power Generation

With the deepening of factory automation, the high efficiency and low cost of active warehouses, elevators, transfer systems, etc., as well as the high speed, high efficiency and high precision of small CNC machine tools, kneading and forming machines, textile and film machinery, etc.

                               The difference between multi-function inverter and general-purpose inverter - LS produces electricity

Multi-function inverters need to meet the following two conditions:

First, regardless of the type of machinery, it can be driven by constant torque load, and even if the load is greatly shaken, it can ensure continuous operation. If the above conditions are not satisfied, the inverter will be easy to stop, difficult to start again, and weak to overload. In order to meet the above conditions, the inverter itself must have a current control function. For example, it is equipped with the function of instantaneous power failure countermeasures and electronic thermal relays to ensure the reliability of work, the self-seeking function necessary for continuous switching from the power grid power supply, and the torque compensation (enhancement) function and stall avoidance function for large load fluctuations. These functions must be based on current manipulation.

Second, the inverter itself should be easy to get used to and match with machinery. In addition to the softwareization of the driving technology, which is widely used in production machinery, it is also important to have optional functions that can be easily adapted to the characteristics of the machine, and input functions to transmit information between the system and the inverter.

Simple general-purpose inverter is a kind of general-purpose inverter that simplifies some system functions with the primary purpose of energy saving. It is mainly used in water pumps, fans, blowers and other occasions where the speed regulation performance of the system is not high, and has the advantages of small size and low price.

In the planning process of high-performance general-purpose inverters, the various requirements that may arise in the inverter application are fully considered, and the system software and hardware are prepared to meet these requirements. When in use, the user can select the algorithm according to the load characteristics and set the various parameters of the inverter, and can also select various spare options provided by the manufacturer according to the needs of the system to meet the special needs of the system.

In addition to being able to be used in all the application fields of simple inverters, high-performance multi-function inverters are also widely used in elevators, CNC machine tools, electric vehicles and other occasions with high requirements for the performance of the speed regulation system. In the past, the general inverter basically used the VVVF control method with a relatively simple circuit structure, which was inferior in torque control performance compared with the vc method. However, with the development of inverter technology, some manufacturers have now launched the choice of VC general-purpose inverter to get used to the increasingly competitive inverter market demand.

This multi-functional universal inverter can be switched to "VVVF operation" or "vc operation" depending on the user's needs, but the price is equal to that of the universal inverter of the VVVF method. Therefore, it is believed that with the development of power electronics and computing technology, the performance-to-price ratio of frequency converters will continue to increase in the future.
More on that
The meaning of servo in LS power production The meaning of servo in LS power production

"Servo" - the word derives from the Greece word for "slave". People want to treat the "servo mechanism" as a handy tame thing, and act in accordance with the requirements of the control signal. The rotor stands still until the signal comes; As soon as the signal arrives, the rotor rolls; When the signal disappears, the rotor can instantly ...

Elements of LS power inverter operation Elements of LS power inverter operation

1. Physical environment (1) Temperature factor Temperature has a huge impact on the lifetime and reliability of the electronic components inside the inverter. When using the inverter in a high operating temperature environment, it is necessary to take additional cooling measures to ensure that the ambient temperature is stable in the inverter.

Analysis of the selection of major ventilator inverters - LS power generation Analysis of the selection of major ventilator inverters - LS power generation

Now enterprises need to use a lot of ventilator inverters, the larger the scale of the enterprise, the more production workshops, the more ventilator inverters will be used. However, no matter how large the enterprise, there is a primary ventilator inverter, the selection of this kind of inverter is very important, because if there is no ...

The vector control mode of low-voltage general-purpose inverter - LS power generation The vector control mode of low-voltage general-purpose inverter - LS power generation

The method of vector control frequency conversion speed regulation is to change the stator current Ia, Ib, Ic of the asynchronous motor in the three-phase coordinate system, after the three-phase - two-phase change, equivalent to the communication current Ia1Ib1 under the two-phase static coordinate system, and then after the directional rotation according to the rotor magnetic field, it is equivalent to synchronous rotation sitting.

Precautions for inverter installation and wiring - LS power generation Precautions for inverter installation and wiring - LS power generation

The inverter is an electric power control equipment that uses frequency conversion skills and microelectronic skills to control the AC motor by changing the power supply frequency of the motor operation. It is used in a wide range of fields, including conveyors, feeders, mixers, grinders, pulverizers, paper cutters, calenders in various industries...

LS power production contactor application LS power production contactor application

LS touchers are divided into AC touchers (voltage AC) and DC touchers (voltage DC), which are used in electricity, power distribution and consumption. Toucher broadly refers to the electrical appliances that use the current flowing through the coil to generate a magnetic field in industrial electricity, so that the contacts are closed, so as to control the load. ...

Relationship between motion control and frequency converter Relationship between motion control and frequency converter

Motion control has a significant period characteristic, it is a combination of a variety of high-tech to push industrial automation, office automation and home automation to a higher stage. At present, the motion control is mainly composed of three parts: inverter, motor and controller. ...

Dealing with intermittent shutdown fault measures - power generation Dealing with intermittent shutdown fault measures - power generation

Because the touch of the network adapter is not good, perhaps due to disturbance and other problems, the DP network that has been used for a long time may show a "transient disconnection" situation, that is, it will be disconnected by an occasional moment, and it will soon recover normally. If OB86 is not downloaded, the CPU will stop during a transient outage. Now all over the option to download a ...

Fatal failure of LS power terminal block Fatal failure of LS power terminal block

From the point of view of application, the function that should be reached is: it is necessary to conduct the local area where the touch part should be conducted, and the touch is reliable. If the insulating part should not be conducted, it is necessary to insulate it firmly. There are three common fatal problems in terminal blocks: ...

LS electric braking unit functions, advantages and operation process LS electric braking unit functions, advantages and operation process

First, the main function of the braking unit In some applications, the need for rapid speed reduction, according to the principle of asynchronous motor, it can be known that if the slip is larger, the greater the torque, the same braking torque will increase with the increase of the speed reduction rate, so that the system speed reduction time is greatly shortened, and the energy feedback is greatly ...

Six misunderstandings in the installation and use of inverters - electricity production Six misunderstandings in the installation and use of inverters - electricity production

Myth 1: Connect electromagnetic switches and electromagnetic touches in the output circuit of the inverter In practical application, some occasions need to use the touch device for frequency converter switching: such as switching to the power frequency state when the frequency conversion is faulty, or the election is used to drag two methods, a motor is faulty, and the variable frequency is used.

Inverter exception handling method - LS power generation Inverter exception handling method - LS power generation

1. The working temperature of the inverter is high 1. Check whether the ambient temperature of the inverter is too high; 2. Check whether the cooling fan inside the device is working properly; 3. Check whether the ventilation pores and mask grilles are blocked; 4. Check if the load is too heavy. ...

The difference between input reactor and output reactor – LS produces electricity The difference between input reactor and output reactor – LS produces electricity

The rectifier part of the general inverter selects the diode uncontrollable bridge rectifier circuit, and the middle filter part selects the large capacitor as the filter, so the input current of the rectifier is actually the charging current of the capacitor, and the harmonic component is relatively steep and steep.

The application of LS inverter in the grinding machine industry The application of LS inverter in the grinding machine industry

First, the process requirements of the grinding machine: The grinding machine is a kind of textile machinery, and its function is to polish the dyed cloth to improve its added value, which is an important process in the printing and dyeing process. The traditional drive mode is driven by a DC motor, which is linked with the lifting rod ...

Power production PLC installation and wiring skills Power production PLC installation and wiring skills

The PLC should be kept away from strong disturbance sources such as electric welding machines, high-power silicon rectifier equipment and large-scale power equipment, and cannot be installed in the same switch cabinet as high-voltage electrical appliances. Power line, control line and PLC power line and I/O line should be separated from the wiring, barrier transformer and PLC and I/O should be selected ...

The cause of motor burnout caused by inverter - LS generates electricity The cause of motor burnout caused by inverter - LS generates electricity

In fact, the problems of the motor are not the cause of the motor itself, most of them are caused by the non-standard debugging of the inverter or the wrong inverter motor when the inverter motor is used, etc., mainly due to the following situations: 1. Put the general motor ...

An internal component of LS's power circuit breaker An internal component of LS's power circuit breaker

1. Auxiliary contact: the contact mechanically linked with the main circuit of the circuit breaker and the closing mechanism is mainly used for the display of the circuit breaker and the closing status, and is connected to the control circuit of the circuit breaker through the opening and closing of the circuit breaker to control or interlock its related electrical appliances. For example, output to signal lights, relays, etc.

What is the difference between LS inverter and LG inverter? What is the difference between LS inverter and LG inverter?

LS inverter and LG inverter are the same, there is no difference between the two. LS inverter, the full name of LS AC inverter governor, after supplying a variety of configurations, converts direct current into communication power, and changes the general power supply ...

LS produces common sense of electroplastic case circuit breaker LS produces common sense of electroplastic case circuit breaker

(1) Tripping LS electric molded case circuit breaker basically involves the tripping unit in the process of practical application, and the tripping is generally a thermomagnetic tripping or electronic tripping, and we must also understand this different tripping method in advance. In practice the application ...

The torque of the inverter is directly used as the controlled quantity mode - LS generates electricity The torque of the inverter is directly used as the controlled quantity mode - LS generates electricity

VVVF frequency conversion, vector control frequency conversion, and direct torque control frequency conversion are all one of the AC-DC-AC frequency conversion. Its common disadvantages are low input power factor, large harmonic current, large demand for energy storage capacitors in DC circuits, and renewable energy can not be reflected back to the grid, that is, it cannot carry out four-quadrant operation.

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top