The communication interface of Delta's inverter is to use RS485 to cooperate with the ModBus communication format commonly used in the general industry for material handing, so as long as the general ModBus software is used, the PC can be used to read and write the materials of the drive.
In addition, for program developers, Delta also provides ModBus DLL files to facilitate program writing and development (DLL files can be downloaded from the download area, and the program controller software can be downloaded to download the Delta Modbus communication library). With the software developed in the above DLL files, you can directly set, monitor and control the internal parameters of the driver.
Ex: The communication of the driver is set to (default value: station number 1, ASCII form), then the driver will be issued ":010620000002D7\x0D\x0A" through ModBus, and the driver will start working. ":010620000001D7\x0D\x0A", the drive will stop working. 01 is the station number, 06 is the function code (written), 2000H is the internal scratchpad of the drive, please refer to Chapter 9 Communication Parameters in each product manual
|
More on that
|
Introduction to Delta's PLC maintenance knowledge
1. Delta's PLC power on running light does not light up, and the ERROR flashes, the reason may be: no program
2. Delta's PLC cannot communicate with the computer, which may be: RS23 port is broken
3. Delta's PLC power light does not light up: The power supply is bad
...
|
|
Delta's inverter power-on debugging method
After the inverter is installed, disconnect the output of the inverter, use the diode file of the digital meter to measure the input and output of the inverter before the power is not turned on, ensure that there is no short circuit, and then turn on the working power supply of the inverter.
|
|
Reduce the failure rate of Delta's inverters
Daily View Item 1:
Check whether the sound of the motor changes abnormally during operation, including whether there is vibration during the operation of the motor.
Project 2:
Check if the environment of the inverter unit has changed. For example, whether the ambient temperature is normal. Familiar with Delta's inverter ...
|
|
Delta's inverter process setting
1. Restore the inverter to factory settings, press the "ENTER" button to enter the parameter setting interface, and press it continuously until it is 00-00 and then stop. Press the number up button to change to 00-02. Press the "ENTER" key again, the panel value will show 0, press the number up key to change it to 9. Press the "ENTER" key, break ...
|
|
Delta's MZM position drive system is used for precise application of large inertia
Driven by consumption promotion and product diversification, the manufacturing industry's demand for automation and intelligent promotion in production and processing is also increasing. In the production process, the processing of "large and heavy" items is often difficult to control accurately, and the error of orientation is not as easy as that of "small" items. To this end ...
|
|
Delta inverter parameter replication error solved
1. SE2 parameter imitation error
Problem Description:
Keypad Imitation Function Fault Correction 2
Solution:
1. The Keypad imitation action is completed, and the inverter parameters are written into error
2. SE1 Parameter Imitation ...
|
|
Delta's PLC-Based motion controller AX3 series
With the development of electronic semiconductor information technology, technologies such as the Internet of Things, big data, and cloud channels are showing a trend of hundreds of schools of thought, which also drives the rapid development of intelligent production. Intelligent production also puts forward new requirements for controllers: high speed, large capacity, miniaturization, networking...... In order to ...
|
|
Inverter optocoupler device type - Delta
1. One is a triode type photocoupler, such as PC816, PC817, 4N35, etc., which is commonly used in the output voltage sampling and error voltage amplification circuit of the switching power supply circuit, and is also used in the digital signal input loop of the inverter control terminal. The structure is the simplest, and the input side consists of a light-emitting two...
|
|
The key point to pay attention to when choosing a UPS power supply - Delta
(1) About the synchronous switching function. Now, in addition to the off-line UPS power supply with an additional output power of less than 500VA, the off-line UPS power supply with square wave output is still selected for conversion control without mains synchronization function, and all UPS power supplies with an output power of 1KVA and above are performing the conversion operation of mains power supply to inverter power supply.
|
|
Delta's inverter fault warning solution
Product series: CP/CH/CT/C2000/C200/MS300/MH300/VE/ED/VJ
Fault Codes:
noCL
Fault clarification:
The lack of oil is correct
Solution:
1. Check the fuel level of the fuel tank
2. Check whether there is any leakage on the oil road.
|
|
Inverter performance test method - Delta
As we all know, the inverter has many maintenance functions, such as overcurrent, overvoltage, overload maintenance and so on. With the continuous improvement of industrial automation, frequency converters have also been widely used. This article will explain to you how to use a multimeter to measure the quality of the inverter.
Need...
|
|
Delta's active front-end and inverter's coordination
The popularity of frequency converters has brought significant energy savings to industrial applications. However, the high-frequency switching signal generated by the inverter is easy to cause electromagnetic interference and affect the power quality. Especially in industries with large loads such as lifting and elevators, it is becoming more and more obvious.
...
|
|
The inverter needs to be equipped with a braking resistor-Delta
The inverter is equipped with a braking resistor, mainly to consume part of the energy on the DC bus capacitor through the braking resistor to avoid the voltage of the capacitor being too high. Theoretically, if the capacitor stores a lot of energy, it can be used to release it to drive the motor to avoid energy waste, but the capacity of the capacitor is limited.
|
|
Precautions for storage of Delta inverter VFD-VE
It must be placed in a ventilated, dust-free, dry place.
The ambient temperature of the storage location must be in the range of -10°C to +40°C
The relative humidity of the storage location must be in the range of 0% to 90% and be free of dew.
...
|
|
A brief introduction to Delta's inverters and their models
Delta's VFD drives have now established a wide range of brand awareness in the industrial automation market. Each series of products is designed for different operation needs such as torque, loss, overload, overspeed work, etc., and is adjusted according to different industrial machinery attributes; It can provide customers with a variety of choices, and a wide range of ...
|
|
The inverter has a built-in PLC function - Delta
PLC progressive scanning standard work preparation.
Abundant programming language: instruction statements; ladder diagram; SFC。
Abundant instruction statements: 45 instruction varieties, including 28 root instructions and 17 usage instructions.
350 step law capacity.
uS-level root directives ...
|
|
Application of Delta A2 servo on packaging twisting machine
Double-end twisting machine is a more traditional sugar block packaging machine, it is widely used in small and medium-sized sugar block production enterprises, with a high degree of automation, which can not only complete the packaging of single or multi-layer paper, but also can package a variety of shapes of hard candy or soft candy.
|
|
Delta's B2 series servo motor parameter setting
Automatic:
P0-02 Drive Status Display Parameter Function: 07Motor Speed (r/min)
P1-01 Control form and control command input source setting parameter function: 02 Select S form (r/min)
P1-38: Zero speed detection accuracy (no response below set speed)
P1-4 ...
|
|
The case of Delta's multi-axis motion controller
The non-standard manipulator can be customized according to the practical needs of customers, because the non-standard manipulator has no specifications to follow, and there is no such kinematic model in the controller, so the development of the control system is difficult. Delta recently provided non-standard manipulators for pharmaceutical board manufacturers to supply control solutions ...
|
|
Composition and function of Delta inverter
Delta inverter is a device that converts the power supply (50Hz or 60Hz) into AC power supply of various frequencies to realize the variable speed operation of the motor.
|
|