Introduction to Delta's PLC maintenance knowledge

Create Date: 2024-8-30 12:03:23|Source: Delta/Delta

1. Delta's PLC power on running light does not light up, and the ERROR flashes, the reason may be: no program

2. Delta's PLC cannot communicate with the computer, which may be: RS23 port is broken

                                 Introduction to Delta's PLC maintenance knowledge

3. Delta's PLC power light does not light up: The power supply is bad

4. When Delta's PLC needs to send out pulses, select a PLC with an output transistor type

5. Delta's PLC output indicator is on, but there is no output: The output point is bad

6. Delta's PLC input wiring is normal, the input terminal is closed, but the input indicator does not light up: the input point is broken

8. Delta's PLC is powered on and the BAT.LOW light is on: The battery is low

10. Delta PLC energized power supply insurance: The power board is short-circuited

11. All indicators of Delta PLC are normal, but all output points cannot be operated: the output expansion IC is bad

12. All indicators of Delta PLC are normal, but the input contacts are not responding: RS232 is bad

13. What are the control methods of Delta's PLC analog quantity: temperature and liquid level?

14. What are the external communication ports of Delta PLC: RS232 and RS485

15. What should I do if the voltage of Delta's PLC drops to the lower voltage limit: Replace it in time

16. Delta's PLC running light is not on, the program is input normally, and the running switch is closed, what is the reason: CPU is broken

17. Delta PLC has 24V output but the power indicator does not light up: The +5V power supply circuit is abnormal

18. Which PLC of Delta cannot be expanded: DVP-EC3

19. Are Delta weigh modules extended on the left or right? Left

20. DVP20PM00M output pulse can reach: 500HZ

More on that
Inverter maintenance and accessories should be replaced regularly – Delta inverters Inverter maintenance and accessories should be replaced regularly – Delta inverters

1. Before the inverter is energized The temperature and humidity of the surrounding environment should be detected first. Too high a temperature will cause the inverter to overheat the alarm. When severe, it will directly lead to damage to the power supply device of the inverter and short circuit of the circuit; Excessive humidity of the air can lead to a direct short circuit inside the inverter. When the inverter is in operation ...

Problems in the inverter application – Delta inverters Problems in the inverter application – Delta inverters

1. Harmonic problems The equipment that plays the role of switching in the main circuit of the inverter must generate harmonics in the process of turning on and off the circuit. The lower harmonics generally have a greater impact on the motor load and cause torque ripple; The higher harmonics increase the leakage current of the inverter's output cable, making ...

EMC Filter Installation Considerations – Delta EMC Filter Installation Considerations – Delta

All electronic equipment (including frequency converters) will generate some high-frequency or low-frequency noise during normal operation, and disturb the peripheral equipment through conduction or radiation. If the right EMC filter can be configured and the correct device method can be used, the disturbance can be reduced to a minimum. ...

Delta's M300 series inverters are used in primary and auxiliary frequency applications Delta's M300 series inverters are used in primary and auxiliary frequency applications

I. Introduction Some devices will have many transmission organizations, and it is impossible for the transmission organization to achieve 100% speed synchronization, so it is necessary to introduce ------ The final motor speed of the pendulum roller is *** := main speed + (+-auxiliary correction change) Use the site ...

How to use Delta's inverter operation How to use Delta's inverter operation

(1) When the speed of the motor is controlled by the Delta inverter, the noise and temperature rise of the motor are higher than that of the frequency of the motor. When the motor is running at low speed, because the speed of the motor blades is low, the temperature rise of the motor becomes high.

Introduction to Delta's RH series switching power supply Introduction to Delta's RH series switching power supply

Delta's RH series switching power supply, RH series switching power supply is a high-quality power supply product series planned by Delta Power for industrial applications, with the characteristics of high rate, high reliability and high function. This series of products has a wide range of input voltages and can be applied to a variety of power input ...

Delta-B series inverter inverter output module is damaged and the drive circuit is damaged Delta-B series inverter inverter output module is damaged and the drive circuit is damaged

Delta-B series inverter inverter output module is damaged and the drive circuit is seriously damaged: the drive integrated circuit T250V or burst, or the output terminal and the power supply ground are short-circuited, the filter capacitor is sprayed, the regulator tube is broken down or open, the resistance is open or the resistance value increases, and the circuit board carbonization is damaged.

Solution: Delta's inverter operation error Solution: Delta's inverter operation error

There are many setting parameters of the inverter, each parameter has a certain selection scale, and the inverter can not work normally due to the improper setting of a single parameter is often encountered in the application, therefore, the relevant parameters must be set correctly. ...

The inverter reported the cause of the grounding fault - Delta The inverter reported the cause of the grounding fault - Delta

Regarding the grounding problem, it can generally be swept away after the following steps (because most of the inverters are not easy to detect the current measurement of Hall components, it is very important to sweep the grounding caused by external conditions, and alternative methods can be selected if there are conditions, and it is still an external problem to change a normal load to see whether it is a problem of frequency conversion or an external problem ...

Post-inverter shutdown maintenance project – Delta Post-inverter shutdown maintenance project – Delta

1. Use a vacuum cleaner with a plastic nozzle to completely clean the inside and outside of the inverter cabinet to ensure that there is no excessive dust around the equipment. 2. Check the ventilation and lighting of the inverter room, and the ventilation equipment can work normally. 3. Check the inverter ...

A number of Delta's new high-end power supply products were unveiled at CMEF A number of Delta's new high-end power supply products were unveiled at CMEF

Delixi Electric's newly launched CDQ1F series PC-level excitation active transfer switch, with more complete specifications and stronger functions, the power-off time can be shortened to less than 0.1s, escorting the continuous use of electricity in important places! CDQ1F Active ...

Selection of Delta power supply Selection of Delta power supply

There are many models of Delta's power supplies, and the currents and functions supported are also different, so how to choose?   VX Series Power Supplies. VX270: Active PFC270w, but 12v is still small and can only be used at low power. Active PFC and 12v output up to 276w at 300...

The impact of grid quality on the life of the inverter – Delta The impact of grid quality on the life of the inverter – Delta

Inverter is a high-tech product, mainly composed of power electronic equipment and microelectronic equipment. The three-phase communication grid is connected to the input of the frequency converter. The input end of the inverter is a rectifier circuit, and the output end is a frequency conversion circuit. As a result, the voltages and currents on the input and output sides include abundant ...

Precautions for the use of Delta inverters Precautions for the use of Delta inverters

1. The inverter must be selected correctly. 2. Read the product manual carefully, and wiring, device and application in accordance with the requirements of the manual. 3. The inverter device should be firmly grounded to suppress radio frequency disturbance and avoid electric shock caused by leakage of the inverter. 4、 ...

Delta's key steps in inverter maintenance Delta's key steps in inverter maintenance

First, the maintenance of the inverter must first check whether the sound in the operation of the motor is abnormal, including, whether the motor is in operation to form a sensation. ​ 2. Check whether the natural environment of the inverter installation has changed. ...

Delta's active front-end and inverter's coordination Delta's active front-end and inverter's coordination

The popularity of frequency converters has brought significant energy savings to industrial applications. However, the high-frequency switching signal generated by the inverter is easy to cause electromagnetic interference and affect the power quality. Especially in industries with large loads such as lifting and elevators, it is becoming more and more obvious. ...

Measures to avoid soft failure of inverters - Delta Measures to avoid soft failure of inverters - Delta

The ways to reduce the soft fault of the inverter are: 1. Detect the overvoltage and undervoltage of the inverter; 2. Detecting overcurrent is the most frequent phenomenon of frequency conversion alarm. Generally, the overvoltage alarm is generally presented at the time of shutdown, and the primary reason is that the deceleration time is too short or the braking resistance and braking unit have ...

Replaced by discontinued models of Delta inverters Replaced by discontinued models of Delta inverters

Delta's new generation of compact and efficient vector-controlled inverter MH300, adhering to the good driving function of Delta's inverter, has six advantages: compact size, flexible application, stable system, reliable quality, and easy installation.

Delta successfully held a seminar on new technologies for electronic power Delta successfully held a seminar on new technologies for electronic power

From May 23 to 25, 2019, the Delta Power Electronics Technology Application Seminar, hosted by Delta Group of Zhejiang University, was held at the KONE Hotel in Wujiang, Jiangsu. Experts and professors from the power electronics technology industry from all over the world and 360 teachers, students and practitioners from more than 10 key universities such as Tsinghua University and Zhejiang University.

Delta's MZM position drive system is used for precise application of large inertia Delta's MZM position drive system is used for precise application of large inertia

Driven by consumption promotion and product diversification, the manufacturing industry's demand for automation and intelligent promotion in production and processing is also increasing. In the production process, the processing of "large and heavy" items is often difficult to control accurately, and the error of orientation is not as easy as that of "small" items. To this end ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top