As we all know, the inverter has many maintenance functions, such as overcurrent, overvoltage, overload maintenance and so on. With the continuous improvement of industrial automation, frequency converters have also been widely used. This article will explain to you how to use a multimeter to measure the quality of the inverter.
It should be noted that for personal safety, the machine must be powered off, and the input power line R, S, T and output line U, V and W of the inverter must be removed before it can be operated! First, the multimeter is put into the "secondary tube" file, and then the red and black pen of the multimeter are detected according to the following process:
The black pen touches the negative pole P(+) of the DC bus, and the red pen touches R, S, and T in turn, recording the displayed value on the multimeter. Then touch the red pen to N (-) and the black pen to R , S and T in order to record the display value of the multimeter. If the six-time display value is fundamentally balanced, it indicates that there is no problem with the rectifier or soft-start resistance of the inverter diode, on the contrary, the rectifier module or soft-start resistor in the corresponding direction is damaged, and the phenomenon: no appearance.
The red pen touches the negative pole P(+) of the DC bus, and the black pen touches U, V, and W in turn, recording the display value on the multimeter. Then touch the black pen to N(-), and the red pen to touch U, V, and W in order to record the display value of the multimeter. If the six display values are fundamentally balanced, it indicates that there is no problem with the IGBT inverter module of the inverter, on the contrary, the IGBT inverter module in the corresponding direction is damaged, and the phenomenon is no output or fault.
A power-matched asynchronous motor is dragged on-site with an inverter to run no-load, and the frequency f is adjusted, which starts from 50Hz and decreases to the lowest frequency.
In this process, the no-load current of the motor is detected with an ammeter, if the no-load current is very stable in the process of frequency drop, and it can persist at all, it is a good inverter.
The lowest Z frequency can be calculated in this way, (synchronous speed - rated speed) × pole pair p÷60. For example, a 4-pole motor has a rated speed of 1470 rpm, and the lowest frequency = (1500-1470)×2÷60=1Hz.
There is no problem with the soft start resistor, on the contrary, the rectifier module or soft start resistor in the corresponding direction is damaged, and the phenomenon: no appearance.
The red pen touches the negative pole P(+) of the DC bus, and the black pen touches U, V, and W in turn, recording the display value on the multimeter. Then touch the black pen to N(-), and the red pen to touch U, V, and W in order to record the display value of the multimeter. If the six display values are fundamentally balanced, it indicates that there is no problem with the IGBT inverter module of the inverter, on the contrary, the IGBT inverter module in the corresponding direction is damaged, and the phenomenon is no output or fault.
A power-matched asynchronous motor is dragged on-site with an inverter to run no-load, and the frequency f is adjusted, which starts from 50Hz and decreases to the lowest frequency.
In this process, the no-load current of the motor is detected with an ammeter, if the no-load current is very stable in the process of frequency drop, and it can persist at all, it is a good inverter.
The lowest Z frequency can be calculated in this way, (synchronous speed - rated speed) × pole pair p÷60. For example, a 4-pole motor has a rated speed of 1470 rpm, and the lowest frequency = (1500-1470)×2÷60=1Hz.
Identification of AC and DC solid state relays: Generally, the input and output terminals of the DC solid state relay shell are marked with "+" and "-" symbols, and the words "DC input" and "DC output" are noted. The AC solid state relay can only mark the "+" and "-" symbols on the input terminal, and there is no positive or negative distinction at the output terminal.
Identification of input and output: Solid state relay without identification, multimeter R×10k file, by measuring the forward and reverse resistance values of each pin to distinguish the input and output terminals. When the forward resistance of one of the two pins is small and the reverse resistance is infinity, the two pins are the input and the other two pins are the output. In a measurement with a small resistance, the black pen is connected to the positive input end, and the red watch pen is connected to the negative input end.
If the forward and reverse resistance of both pins is measured to be 0, it means that the solid state relay has broken down. If the forward and reverse resistance values of each pin of the solid state relay are measured to be infinite, it means that the solid state relay has been damaged by an open circuit.
|
More on that
|
Excessive inverter capacity poses a hazard to electrical equipment – Delta
(1) The harmonic current will directly cause the additional heating of the motor, so that the stator of the motor will exceed the rated temperature rise of the motor itself, so that the rated output capacity of the motor will be greatly reduced.
(2) The current wave output of the inverter ...
|
|
Precautions for the inverter installation environment – Delta
(1) Ambient temperature:
Like other electronic equipment, the inverter has certain requirements for the ambient temperature, which is generally "-10-+40°C". Because the inverter is a high-power electronic equipment, it is very easy to be affected by the working temperature, but in order to ensure the safety of the inverter's work.
|
|
Inverter maintenance is easy to ignore the problem - Delta
1. After the inverter is repaired, the power number needs to be corrected, don't forget it
Generally, an inverter corresponds to a power number (also known as the number of horsepower), for example, a 75 kilowatt inverter is set under heavy load, and 100 kilowatts is set under light load. In this way, the customer will not use it to present ...
|
|
Inverter setting method - Delta
The first step is type recognition: acknowledging whether the type of inverter is common to the type of inverter purchased. If not, ask the agent to return the item.
Step 2: Shipping Acknowledgement: After opening the package, check whether the inverter is damaged during transportation. If there is damage, let the agent return ...
|
|
Selection of Delta power supply
There are many models of Delta's power supplies, and the currents and functions supported are also different, so how to choose?
VX Series Power Supplies.
VX270: Active PFC270w, but 12v is still small and can only be used at low power.
Active PFC and 12v output up to 276w at 300...
|
|
Failure analysis of Delta inverter VFD-VL series
Fault 1: Overcurrent in acceleration
Clarification: Overcurrent in acceleration
Solution 1: Check whether the wiring from U-V-W to the motor is poorly insulated;
2: Increase acceleration and deceleration time;
3: Replace the inverter with a larger output capacity;
4: Reduced (P54) torque ...
|
|
The frequency of the inverter is given in a given way - Delta
The main way to use the inverter is to change the output frequency to achieve the controllability of the motor speed, so do you know what steps are required to complete the output frequency controllability? One of the main points is how to complete the change of the frequency signal supplied by the inverter equipment.
|
|
Delta's active front-end inverter partner
The ubiquity of AC drives brings significant energy savings to industrial applications. However, the high-frequency switching signal generated by the inverter is easy to form electromagnetic disturbance, which affects the power quality. It is especially significant in occupations with large loads such as lifting and elevators.
At this time, the inverter ...
|
|
Delta's key steps in inverter maintenance
First, the maintenance of the inverter must first check whether the sound in the operation of the motor has changed abnormally, including, whether the motor is in operation to form a sensation.
2. Check whether the natural environment of the inverter installation has changed. For example, whether the operating temperature is normal. Learn more about Delta's inverter ...
|
|
Delta's Ultron HPH provides power protection that meets the needs of green data centers
Delta's Ultron HPH series UPS has an AC-AC efficiency of up to 96%, and can reach 99% in ECO mode, with significant energy savings. The flexible airframe provides a compact footprint (40kW / 0.15 m2) and reduces space waste. With an interface-friendly 5-inch colorful touch screen, ...
|
|
Precautions for Delta inverter C2000 series
1. Precautions for choosing a communication motor driver
When using a large-capacity current transformer (more than 600kVA) and a phase-entering capacitor, the surge current on the input side of the power supply is too large, which may destroy the input side of the communication motor driver.
|
|
Basic parameter setting of special inverter for wind turbine - Delta
1. Control mode:
i.e. speed control, torque control, PID control or other methods. After the control method is adopted, static or dynamic identification should generally be carried out according to the control accuracy.
2. Minimum operating frequency:
That is, the minimum speed of the motor. When the motor is working at low speed, the ...
|
|
Solution to the problem of inverter undervoltage - Delta
In order to protect the inverter, when the bus voltage is too low, the inverter will report the undervoltage problem and close the pulse output of the inverter. This is an important and necessary way to protect the inverter equipment from damage. This issue also cannot be blocked.
...
|
|
Detection methods for Delta circuit breakers, AC contactors and frequency converters
1. Circuit breaker
A circuit breaker is a device that can be manually or automatically controlled, and is used to control the on/off of the system power supply in the equipment circuit system. When there is a suspicion that there is a defect in the electrical system of the equipment, the primary functional part of the power supply should be checked.
Under normal circumstances, when in the ON state, the input input ...
|
|
Delta's M series inverter communication parameter address problem
In Delta's M series inverters, the parameter address 2000H corresponds to abort, start, JOG, and forward, rotation, and change direction. Why is "aborted" at the time of writing the program H01, "start" is H10, "forward" is H12, and "rotation" is H22.
...
|
|
Delta's Amplon N series UPS ensures the safety of electricity consumption in pharmaceutical production lines
In recent years, in response to the development trend of automation, informatization and intelligence, pharmaceutical companies have continuously innovated, transformed and upgraded, selected fully automated intelligent production lines, accelerated the upgrading of equipment in the pharmaceutical industry, and completed the use of smart pharmaceutical technology for green, safe, high-quality and low-consumption development in the pharmaceutical industry.
|
|
Delta's soft starter component role
The soft starter is a device used to control the start and stop of the motor, which is composed of a number of components, including the soft starter controller, the soft starter conditioner, the soft starter power supply, the soft starter input and output module, the soft starter interface module, etc.
...
|
|
Cause of Servo Motor Failure – Delta
1. The motor is broken shaft
1. The cause of the problem
(1) Unreasonable mechanical design leads to excessive radial load force;
(2) The load end is stuck or severely overloaded;
(3) The motor and reducer are not centered when installed.
2. Eliminate problems
(1) Check the ...
|
|
Whether the inverter needs to be added to the line - Delta
The role of the "communication input reactor" of the inverter input device is mainly to improve the power factor of the communication power supply on the communication side of the input side; It is useful to eliminate the higher harmonics on the input side to avoid damage to other electrical equipment caused by voltage distortion; Eliminate the three-phase AC power phase ...
|
|
Important parameters of Delta inverters
The inverter is the pioneering work of Delta Automation, and it is also the largest selling product of Delta Automation. In the highly competitive market, Delta inverters have always maintained a strong growth momentum and made great achievements in the high-end product market and the economic product market. Delta continues to launch high-end products ...
|
|