As we all know, incremental encoders are used to monitor rotational speed or position, and are widely used in all kinds of automated machinery. With the continuous development of the industrial control industry and the continuous change of product demand, SICK has launched the cost-effective incremental encoder DLS40 in the large and highly competitive small incremental encoder market.
The rapid development of the industrial Internet has promoted the development of industrial equipment to miniaturization and integration, and the requirements for sensor size are becoming more and more compact, and the thickness of DLS40 directly exceeds 20mm, and the compact design simplifies the installation of the encoder, even in the limited installation space, there is no need to worry about installation problems, and the overall size of the machine is significantly reduced.
1. Product features
• Complete electrical interfaces, NPN open collector, HTL/push-pull and TTL/RS422 differential signals
"Seamless" switching with mainstream mechanical structures and electrical signals in the market
• Compact size, the thickness is directly reduced from 36-38mm to 20-25mm
Greatly reduce the space size required at the rear end of the motor, saving equipment space
• The product manual is printed on the encoder body in the form of a laser QR code.
You can scan the QR code to check the manual anytime and anywhere
• The product is highly compatible, with universal 6, 8, 10, 12mm shaft diameter and standard 2m cable design. Even the cable color line sequence is fully compatible with the mainstream of the market.
According to different use requirements, to provide customers with convenient and fast customized services
2. Product parameters
• Electrical interface: TTL/RS422, HTL/Push-Pull, open collector NPN
• Temperature range: -10°C - 70°C
• Resolution/number of lines: 10 - 1024
• Product thickness: 20mm solid shaft, 25mm blind hole
• Optional function: Status indication
• Mechanical interface: solid shaft 6mm
• Blind hole: 6/8/10/12mm
• Degree of protection: IP50
• Connection: 2m cable (standard)
3. Application industry
wrap
The DLS40 is used to measure bag lengths, cut and monitor conveyor belt speeds.
Textile printing and dyeing
The motor installed in the machine is used to monitor the speed of the textile machine and control the length of the textile, too fast or too slow will directly affect the quality of the fabric produced in the final production.
AGV
It is installed on the speed wheel to monitor the driving speed of the AGV, and the driving wheel drives the encoder to run, and the travel speed is controlled by collecting the pulse value of the encoder.
printing
It is used for speed monitoring of printing equipment to avoid improper speed control in the production process, which affects the printing quality or causes a large amount of printing waste.
|
More on that
|
Sick Sensors – How to use the Contrast Sensor
1. Wiring There are 4 outgoing wires of the sensor, among them, the red or brown wire is connected to the positive power supply, and the black wire is connected to the negative power supply; The green or blue wire is the dark output line, and the white or yellow wire is the bright output line, the user can choose one of them according to his needs, and the other is not used, but it should be insulated. The lines are not ...
|
|
Sick Sensors – The system composition of ultrasonic sensors
Transmitter: An oscillator (usually ceramic, about 15 mm in diameter) vibrates to generate ultrasonic waves and radiate them into the air.
Receiver: When the oscillator receives the ultrasonic wave, it generates the corresponding mechanical vibration according to the ultrasonic wave and converts it into electrical energy as the output of the receiver.
...
|
|
Introduction to the advantages and disadvantages of Sick Sensors - thermistor temperature sensors
Advantages of thermistor temperature sensors:
1. Thermistors are highly sensitive and can easily detect temperature changes.
2. Most models can respond quickly to temperature changes, which can be completed in a few seconds.
3. The technology is mature, the cost is low, and the user ...
|
|
Adjustment method of the Sick WFS3-40N415 sensor
(1) Automatic calibration: When the workpiece enters the sensitive area of the probe, press and hold the "SET" button for 3 seconds, and the sensitivity value will be set and displayed in green.
(2) Two-point calibration: When the workpiece does not enter the sensitive area, hold and hold the "SET" button for three seconds, there is a ...
|
|
Sick OD2000 laser displacement sensor was launched
The OD2000 is an excellent multi-range sensor with a laser displacement sensor measuring within 1,200 mm with high accuracy. Technology based on the principle of laser triangulation, as well as the versatility of the measuring range, make it suitable for many different industry applications.
OD2000 multi-range not only solves the problem of electric ...
|
|
Sick sensors – how to work and how to use color mark sensors
How the color mark sensor works
The color mark sensor is actually a reverse installation, the light source is perpendicular to the target object device, and the bearer is biased towards the device at an acute angle to the object, so that it only detects the scattered light from the target object, and then prevents the sensor from directly bearing the reflected light, and can make ...
|
|
How to adjust the SICK UM18-51112 sensor
Preparation tools: calibrator to change the distance of the ultrasonic sensor, special regulator and special power supply.
Disconnect the power supply: Disconnect the ultrasonic sensor from the controller and prepare it for commissioning.
Commissioning time: The commissioning time can be adjusted to any time to meet the needs of personalization.
|
|
Sick sensors – the future of photoelectric sensors
Photoelectric sensors are controlled by converting changes in light intensity into changes in electrical signals.
Photoelectric sensors are generally composed of three parts: light source, optical path and optoelectronic components. The measured change is converted into a change in the optical signal, and then the optoelectronic component is used to further ...
|
|
Sick Sensors – Precautions for the use of color mark sensors
1. Be sure to check whether the power supply used is in line with DC12-24V±10%, and the maximum is not more than 40V, otherwise the photoelectric switch may be damaged.
2. In order to ensure high stability detection, it is necessary to ensure that two points are achieved: first, the detection distance meets the specified rated detection distance, such as the detection distance is 12±2mm ...
|
|
The difference between 1D, 2D and Sick RF tags
In our daily lives, we can easily see a large number of 1D and 2D codes everywhere, and such visual barcodes have become one of the main applications of track and trace technology in various modern automation applications.
With the iteration of technology updates, more and more ...
|
|
Sick Sensors – How to use the Contrast Sensor
1. There are 4 wires for the wiring sensor, among them, the red or brown wire is connected to the positive power supply, and the black wire is connected to the negative power supply; The green or blue wire is the dark output line, and the white or yellow wire is the bright output line, the user can choose one of them according to his needs, and the other is not used, but it should be insulated. Lines are not allowed ...
|
|
Introduction to the functions and characteristics of Sick sensors
1. At present, SICK pressure sensors can be used in combination with computers and instruments to improve operation and reduce errors. The human-machine dialogue function is the main feature of SICK pressure sensors, and the display device and input keyboard equipped with it become the medium for human-machine dialogue.
2. SICK pressure sensing ...
|
|
Parameter settings for the Sigg distance sensor
1. Set to "Surface" to measure the distance from the first surface within the sensor's detection range. This setting is available for all sensor heads.
2. Set to Glass Thickness to measure the distance from the front to the back of a transparent object, such as glass. This means that it has been measured with the sensing ...
|
|
Common faults of SICK sensors
1. The pressure receiver transmitter cannot return to the zero position
The output of the SICK sensor does not change, and the output of the repressurized transmitter changes suddenly. Once the sensor is tightened, the sealing ring is compressed to the sensor pressure port to block the sensor. When pressure is applied, the pressure medium cannot ...
|
|
Sick Sensors - Infrared sensors are classified according to the way they are emitted
Depending on the way of transmission, infrared sensors can be divided into two types: active and passive.
1. Active infrared sensor
The transmitter of the active infrared sensor emits a modulated infrared beam, which is received by the infrared receiver, thus forming a warning beam composed of an infrared beam ...
|
|
Adjustment method of Sick sensor NT6-03022
1. Self-regulation. At the beginning of use, please check whether the switch itself is defective and whether the appearance is defective.
2. When avoiding obstructions. When the photoelectric switch is used, for some goods such as colored goods, goods with weak reflectivity, and goods with large gaps between small pieces...
|
|
Sick sensor – the difference between photoelectric sensor and infrared sensor
Photoelectric sensors
A photoelectric sensor is a device that converts an optical signal into an electrical signal. Its working principle is based on the photoelectric effect. The photoelectric effect refers to the phenomenon that when light hits some substance, the electrons of the substance absorb the energy of the photons, and the corresponding electrical effect occurs. According to the photoelectric effect ...
|
|
Sick Sensors – the working principle and application of color sensors
What are the applications of color sensors?
1. Discrete photodiode with color filter
The traditional color sensing method uses a structure in which three to four photodiodes are combined on a single chip, and red, green, and blue filters are placed on the surface of the photodiodes. An independent ...
|
|
Sick Sensors – A detailed introduction to the principles of the five common pressure sensors
1. Piezoelectric pressure sensor
Based on the piezoelectric effect, electrical components and other machinery are used to convert the pressure to be measured into electricity, and then perform related measurement work. Piezoelectric sensors can only be used for dynamic measurements. Host...
|
|
Sick has launched its latest MDA Vision system
In the current era of rapid economic development, logistics is known as the "blood" of the national economy, although the early Chinese logistics industry started late, with the continuous improvement of the system, the rapid development of high and new technology, now the logistics industry has become a social and economic bridge and link. Among them, the data flow is ...
|
|