How to choose the right inverter for the motor?
The inverter is an electric transmission element that is used in frequency conversion skills and microelectronics skills to control and communicate with the motor by changing the frequency and fluctuation of the power supply of the motor.
The birth of the inverter cabinet originated from the communication motor ...
|
|
Schneider Electric miniature circuit breaker accident prevention
With the development of the electric power industry, now the electricity has been accompanied by every detail of our days, so the maintenance of the electric power industry, began to get more and more attention from everyone, because the circuit in the daily operation side, very simple because of overvoltage or undervoltage and present a certain problem, which ...
|
|
Precautions for the selection of Schneider foot switches
The foot switch series is XPE, and it should be noted when selecting:
1) Raw materials: metal and plastic, which are used in heavy-duty, high-risk, light-duty, low-risk occasions.
2) Pedal: divided into single pedal and double pedal (type end plus D).
3) With or without maintenance cover ...
|
|
The energy-saving effect of using frequency converter for fan and pump loads
Why is the use of inverter for fan and pump loads to save energy?
According to the basic laws of fluid mechanics, it can be seen that the fan pump load is a typical square rotation load, and its main characteristics are: speed n and torque T and load ...
|
|
The ultimate short-circuit breaking capacity of Schneider circuit breakers
The limit short-circuit breaking ability (ICU) refers to the short-circuit current that can be turned on and broken under certain experimental parameters (voltage, short-circuit current, power factor) and through a certain experimental procedure, and after this on-off, it will no longer continue to carry its rated current. It's experiments ...
|
|
The comprehensive utility of the inverter control circuit - Schneider
(1) The operation circuit compares the external speed, torque and other instructions with the current and voltage signals of the detection circuit to determine the output voltage and frequency of the inverter.
(2) The voltage and current detection circuit are the same as the main loop potential ...
|
|
Schneider thermal relay selection method
1. In principle, the ampere-second characteristics of the Schneider thermal relay should be as close as possible to or even coincide with the overload characteristics of the motor, or under the overload characteristics of the motor, and at the same time, the Schneider thermal relay should not be affected (not acting) at the moment of short-term overload and start of the motor.
...
|
|
Schneider inverter inverter field interference solution
1. Use software anti-disturbance method
In detail, the carrier frequency of the inverter is lowered through the human-machine interface of the inverter to an appropriate scale. If this method does not work, then the following hardware anti-disturbance method can only be adopted.
2. Carry out positive ...
|
|
Advantages and disadvantages of orifice flowmeters – Schneider
The orifice flowmeter is a high-range ratio differential pressure flow device composed of a standard orifice plate and a multi-parameter differential pressure transmitter (or differential pressure transmitter, temperature transmitter and pressure transmitter), which can measure the flow rate of gas, steam, liquid and natural gas. Widely used in petroleum, chemical, metallurgy, electric power ...
|
|
Schneider instrumentation maintenance precautions
1. Don't blindly knock and bump when overhauling to avoid expansion failures, and the more you repair, the worse it gets.
2. Do not plug and unplug various control boards and plugs with electricity. Due to the strong induced electromotive force generated by plugging and unplugging the control board under the power-on condition, the instantaneous ...
|
|
Instrumentation anti-interference measures - Schneider
The interference encountered by sensors and instruments in the field operation is varied, and the specific situation is analyzed on a case-by-case basis, and the principle of anti-interference is to adopt different methods for different disturbances. This flexible and mobile strategy is undoubtedly opposed to universality, and the way to deal with it is to choose a modular approach, except for ...
|
|
Precautions for Schneider to use USP power supplies
(1) When using Schneider UPS power supply, the relevant provisions of the manufacturer's product manual should be strictly adhered to ensure that the front and zero line sequences of the mains connected by Schneider UPS meet the requirements.
(2) The main intention of equipping Schneider UPS is to prevent the computer from losing information due to a sudden power failure...
|
|
How long does a UPS power supply last after a power outage – Schneider
The UPS power supply can supply power for a period of time after the power is cut off, but how long can the UPS power supply be powered after the power outage? UPS power supply manufacturers said that the power supply time of UPS power supply is inconsistent according to the load power, the number of batteries and other factors.
...
|
|
Schneider inverter enters the parameter setting method
1. The first step is to check whether the inverter is connected to the line, and whether the wiring of the control line and the power circuit is correct
2. Next, turn on the power of the inverter, enter the motor parameters, and perform motor identification
3. Next, set the function parameters to launch the ...
|
|
Design and calculation method of inverter braking resistance - Schneider
1. The number of braking resistor boxes is roughly calculated as: motor power (KW)/11.2 (take the upper limit of the integer).
2. The selection of the power of the braking unit is generally (1-2) times the power of the inverter;
3. The function of braking resistor ...
|
|
Schneider inverter knowledge points
1. Use the analog output port to indicate the motor frequency, when the motor frequency is 50Hz, why is the output only 16mA?
Due to the maximum output frequency parameter of the inverter "TFR", the factory default value is 60Hz. So when the inverter output is 50Hz, the analog output is 16mA. At this time, only ...
|
|
The contents of the daily inspection of Schneider inverters
1) Whether the ambient temperature is normal or not, it is required to be in the range of -10-+40 °C, and it is better to be about 25 °C. whether the humidity meets the requirements, and whether the ventilation and heat dissipation of doors and windows are outstanding; Whether the lower air inlet and upper air outlet of the inverter are dusty or blocked due to excessive dust.
...
|
|
The layout of the inverter is composed of Schneider
rectifier
Many converters use diodes, which convert the power frequency power supply to DC power. It is also possible to form a reversible converter with two sets of transistor converters, because the purpose of the power target is reversible and can be regenerated for operation.
Flat wave back
After the rectifier rectification ...
|
|
The difference between Schneider UPS and EPS power supply
1. Different safety standards
UPS is mainly used to protect users' equipment or business from economic loss, and its product technical certification mainly includes Thiel certification, CQC certification, etc. The development of EPS power supply stems from the sudden failure of the power grid, in order to ensure the power safety and fire linkage needs, it can be supplied immediately.
|
|
Schneider circuit board maintenance work commonly used instrumentation
Before preparing to do circuit board repair work, you should prepare some things and appearances to help repairers better carry out circuit board repair operations, according to our circuit board repair training center for many years of experience has shown that prepare some necessary circuit board repair things and appearance, to be able to reach ...
|