Analysis of the causes of frequent overcurrent alarms of inverters - Schneider
(1) Caused by incorrect parameter setting.
If the acceleration time of the inverter is set too short, the change of the output frequency of the inverter far exceeds the change of the motor frequency, and when the inverter is started, it will trip due to overcurrent. Adjusting the acceleration time accordingly to different load conditions can eliminate this problem.
|
|
The ultimate short-circuit breaking capacity of Schneider circuit breakers
The limit short-circuit breaking ability (ICU) refers to the short-circuit current that can be turned on and broken under certain experimental parameters (voltage, short-circuit current, power factor) and through a certain experimental procedure, and after this on-off, it will no longer continue to carry its rated current. It's experiments ...
|
|
Knowledge of Schneider Lexium32 servo motors
Schneider Lexium32 servo motor new generation servo release enriches Schneider Electric's high-end product line, its outstanding product functions, sensitive openness and user-friendly planning will better meet the high functional and safety requirements of industrial customers. In China's industrial production is increasingly moving towards energy-saving ...
|
|
Schneider thermal relay selection method
1. In principle, the ampere-second characteristics of the Schneider thermal relay should be as close as possible to or even coincide with the overload characteristics of the motor, or under the overload characteristics of the motor, and at the same time, the Schneider thermal relay should not be affected (not acting) at the moment of short-term overload and start of the motor.
...
|
|
Schneider Electric has announced the launch of its Pacific Foundation
Schneider Electric has announced the launch of its Pacific Foundation, which will provide financial and advisory support to charitable foundations in the Pacific region to address fundamental human rights issues of access to energy. Four foundations were selected as the Foundation's initial recipients.
|
|
Schneider ATV71 inverter installation and modulation setting steps
1. Schneider inverter menu:
(1) Simple start:
Self-tuning: If the manifestation is "unfinished", then select "supplication self-tuning" until the manifestation is "finished", i.e., the completion of self-tuning;
Acceleration moment: a ...
|
|
Schneider inverter motor control mode
Fundamentals of magnetic flux vector manipulation
The control of a three-phase asynchronous motor is much more messy than that of a DC motor because the current, voltage, induced potential, magnetic flux, etc., of the stator and rotor are all alternating.
However, the stator winding of the three-phase asynchronous motor is a symmetrical three-phase winding, which exerts a ...
|
|
Schneider inverter and PLC connection problems
When the inverter is used to form an automatic control system for control, in many cases, PLC and inverter are used together, and how to correctly connect the PLC and inverter together has become the key to the success of the system.
1.PLC switch ...
|
|
Key points of maintenance of Schneider battery
(1) Insulating pads should be arranged in the maintenance channel of the battery pack.
(2) It is strictly forbidden to use batteries of different manufacturers, different capacities and different models in the same system.
(3) VRLA batteries do not need to be charged for the first time before use, but should be recharged. Replenish the charge ...
|
|
Schneider servo drive fault code
1. AL001: overcurrent, the current value of the main 2113 circuit exceeds the motor instantaneous 5261*** high current value 1.5 times when the action is 4102.
2. AL002: overvoltage, the voltage value of the main return 1653 channel is higher than the standard value.
3. AL003: low voltage, the voltage value of the main circuit is lower than the standard.
|
|
Schneider inverter simple question
1. How to complete the control of ATV38 and ATV58 through the operation panel?
First, in the control menu, set "LCC" to "YES" (panel operation); Enter the "LFR" parameter in the adjustment menu, press the up and down keys to adjust the given value, and complete the control of the inverter.
...
|
|
Schneider inverter ATV32 book type performance and advantages
Schneider ATV32 book inverter has built-in programmable controller function, flexible and intelligent; Integrated safety functions, 30% cost savings compared with external security modules; First-class Schneider patented synchronous motor open-loop control technology; Book-type design, support side-by-side installation, space-saving; Many...
|
|
Schneider miniature circuit breaker code calling
Schneider miniature circuit breaker code marking method
For example: 1-C65N-C20A/2P+VE+30mA+SD, the meaning of each item is:
1--------- identification number
C65 ------ serial code
N -------- breaking ability, N is 6000A, H is 10000A, L is 15kA
...
|
|
Schneider Instrumentation Classification Standard
The classification specifications for the appearance of the instrument are as follows:
The appearance of the instrument is a comprehensive product of a variety of science and technology, with a wide variety of varieties, wide application, and constantly updated, and a variety of classification methods. According to the purpose and use of the use of the main measuring instrument, car appearance, tractor appearance, marine ...
|
|
How to choose a Schneider circuit breaker?
First, calculate the value of the current of each branch
(1) Purely resistive loads, such as bulbs, electric heaters, etc., are directly divided by the indicated power by voltage, that is, the formula I = power/220v; For example, a 20w bulb, branch current I=20W/220=0.09A electric air ...
|
|
How can industry be high-quality and sustainable? - Schneider
Sanya, China, October 21, 2021 – In the context of the ever-changing global development situation and the increasingly urgent response to carbon neutrality, Ruan is moving towards carbon neutrality together with cost reduction and efficiency increase, which has become the focus of attention of many industrial enterprises. As a global digital transformation specialist in power management and automation...
|
|
The inverter has a problem supplying power to the motor – Schneider
A frequency converter is a device that converts power to other frequencies of power supply. The power frequency of our country is 50Hz, in the field of motors, in order to change the speed of the motor, or other performance changes, many motors choose inverter power supply.
The inverter is a supporting operation with the inverter motor.
|
|
Common faults and judgments of Schneider inverters and controllers
Reducing power consumption is also a key point reflected, because Taiwan imports power proportion of 99%, improve power efficiency, comprehensive development of power transformation is the absolute direction, in the future Schneider each new product will also buckle the two major tones of energy saving and intelligence, in the words quite Schneider to from the power expert identity ...
|
|
Frequency converter control motor leakage solution - Schneider
Because the current at the input and output ends of the inverter contains high-frequency components, the leakage current formed by the high-frequency components when the inverter is driven is greater than that when the grid power supply is supplied. Because there are many varieties of circuit breakers, in some cases, even the inverter wires and motors ...
|
|
The meaning of the inching of Schneider inverter
The inch movement in Schneider inverter means that the control signal can drive the motor intermittently according to the certain rules, and the motor acts in strict accordance with the dynamic and stop instructions of the control signal, and the motor does not roll by inertia during the shutdown. It's like moving an inch and then stopping.
The full name of Schneider inverter is "...
|